Voltage Protection Relays
Star Converter Module
We introduced Intelligent Motor Protection Device Integrated with Delta-Star Converter Module for Energy Saving purpose. Application of this device is on variable load where in certain condition motor draws power less than 50% of its capacity. In this condition if we convert the motor in to Star configuration instead of Delta by means of Power Contactor, its Power Factor will be improve & motor will draw lesser power than that in Delta Configuration. There is inbuilt Star-Delta timer in our Motor Protection Device Model- i.MWM-IO. When we start the motor, it will start by Star to Delta method through our device. No additional Star-Delta Timer is required. After motor converts to Delta, device will monitor the power drawing by motor. When the power value is below the Set value of parameter in 'Under Power', after pre define set time (Programmable for 3 to 50 Second) motor will again convert to Star by help of Power Contactor. If again power increases & cross the Under Power value after pre define set time (Star-Delta time programmable for 3 to 15 Second) motor will convert to Delta by help of Power Contactor.
...moremulti function meter
We are a leading Manufacturer of multi function meter from Surat, India. We introduced Intelligent Motor Protection Device Integrated with Delta-Star Converter Module for Energy Saving purpose. Application of this device is on variable load where in certain condition motor draws power less than 50% of its capacity. In this condition if we convert the motor in to Star configuration instead of Delta by means of Power Contactor, its Power Factor will be improve & motor will draw lesser power than that in Delta Configuration. There is inbuilt Star-Delta timer in our Motor Protection Device Model- i.MWM-IO. When we start the motor, it will start by Star to Delta method through our device. No additional Star-Delta Timer is required. After motor converts to Delta, device will monitor the power drawing by motor. When the power value is below the Set value of parameter in 'Under Power', after pre define set time (Programmable for 3 to 50 Second) motor will again convert to Star by help of Power Contactor. If again power increases & cross the Under Power value after pre define set time (Star-Delta time programmable for 3 to 15 Second) motor will convert to Delta by help of Power Contactor.
...moreMotor Protection Relays
Motor protection relay
Standard Features: Selectable IT Curve OR Definite Time Selectable Trip Time for SPP & UL Selectable Rotor Locked Value Optional Feature : Separate Relay for U/L Protection 4 to 20mA Output Two Separate Relay output available
...moremicro processor
Be first to Rate
Rate ThisOpening Hours