industrial air dryer
27,000 Per Piece
Compressed Air Dryer
50,000 Per Piece
Best Deals from Air Dryers
Air Washer Plant
250,000 Per Units
Compressed Air Dryer Dessicant
Get Price Quote
The compressed air is passed through a pressure vessel with two “towers” filled with a media such as activated alumina, silica gel, molecular sieve or other desiccant material. This desiccant material attracts the water from the compressed air via ‘adsorption’ process. As the water clings to the desiccant, the desiccant “bed” becomes saturated. The dryer is timed to switch towers based on a standard time cycle, once this cycle completes some compressed air from the system is used to “purge” the saturated desiccant bed by simply blowing the water that has adhered to the desiccant off. Technical Specifications: Maximum Pressure Capacity: 16 bar Standard Flow Capacities: 10, 20, 40, 50, 60, 80, 100, 125, 150, 200, 250, 300 CFM and so on Pressure Dew Point (PDP): -20°C up to -70°C
Hot Air Dryer
Get Price Quote
User friendly design comprising of viewing window, sliding plate, hinged structure makes operation easier, Dryers are equipped with 7 days timer which helps in programming your production schedule.
Refrigerated Air Dryers
20,000 - 500,000 Per Piece
1 Piece(s) (MOQ)
Air Dyer
Get Price Quote
1 Piece (MOQ)
Air Bubble Film Plant
3,800,000 - 6,800,000 Per Set
1 Set (MOQ)
Air Dryers
Get Price Quote
We are the main supplier of this product.
High Pressure Air Dryer
Get Price Quote
Moisture, either liquid or vapor, is present in compressed air as it exits the compressor system. If this moisture is not properly removed, your compressed air system can lose efficiency and require dramatically increased maintenance, which can result in costly downtime.The majority of pneumatic instruments and processes can not tolerate hot compressed air, compressors are normally supplied with after-coolers and moisture separators. After-coolers are heat exchangers that utilize either water or ambient air to cool the compressed air. As the water and lubricant vapors within the compressed air cool, a significant amount condenses into liquid. An after-cooler discharging compressed air at 100F passes 67 gallons of water per 1,000 scfm per 24 hours.To avoid these problems, compressed air systems have purification devices available to remove the water vapor and other contaminants. The proper selection of these devices is critical as pneumatic applications and compressed air systems become increasingly sophisticated.
Heatless Air Dryer
65,000 Per Piece
SD Membrane Dryers
500,000 Per Piece
LOW PRESSURE AND HIGH PRESSURE AIR DRYER
Get Price Quote
Moisture, either liquid or vapor, is present in compressed air as it exits the compressor system. If this moisture is not properly removed, your compressed air system can lose efficiency and require dramatically increased maintenance, which can result in costly downtime.The majority of pneumatic instruments and processes can not tolerate hot compressed air, compressors are normally supplied with after-coolers and moisture separators. After-coolers are heat exchangers that utilize either water or ambient air to cool the compressed air. As the water and lubricant vapors within the compressed air cool, a significant amount condenses into liquid. An after-cooler discharging compressed air at 100F passes 67 gallons of water per 1,000 scfm per 24 hours.To avoid these problems, compressed air systems have purification devices available to remove the water vapor and other contaminants. The proper selection of these devices is critical as pneumatic applications and compressed air systems become increasingly sophisticated.
Air Washer Plant
Get Price Quote
The basic components of an air washer system are a chamber that contain a series of spray nozzles, an eliminator section that removes water from the air that is exiting the air washer and a sump which catches both the sprayed water droplets and the water that was collected by the eliminators. The spray section will either add moisture to the air or dehumidify the air, while washing solid particles out of the air. The eliminator section in many cases is a "W" or a series of "W"s in shape. This section, forces the air to contact the eliminator components, which in turn knocks down water droplets and air borne solids. The sump is the collection basin for the system. The washed out solids, lint, dust, and water all collect in this area.
Pollution Control Plant
200,000 - 300,000 Per Unit
Vacuum Hopper Loader Dryer
44,000 - 45,000 Per Piece
heatless air drier
Get Price Quote
Available with us are superior quality Heat less Air Drier that are provided with chemical desiccants such as silica gel, activated alumina and molecular sieves that are capable of absorbing moistures on its surface hence drying the air. Our heatless driers are provided with columns that are filled with the chemical absorbent. When the columns in the driers reach the saturation point, one the columns restores the drying capacity through regenerating process. During regenerating process, 15% of the dried air is used to blow out the moisture containing air. Our customers can buy from us these heat less air driers that consume less time for drying.
Compressed Air Dryer
28,500 Per Units
5 Units (MOQ)
Heatless Dryer
Get Price Quote
The Heatless dryers are ideal for low flow air Drying operations. Dryer operation is fully automatic and outlet dew points as low as (-40°C) can be achieved. Heatless regeneration desiccant dryer is designed to protect Pneumatic equipment, controls and processes, from the harmful and costly effects of moisture in compressed air and natural gas lines. Regenerative desiccant dryers operate on the principle of pressure swing adsorption, where a fraction of dry air or gas is used to regenerate the off-stream tower. No heat or exhaust power is required for desiccant bed regeneration. In natural gas applications, purge exhaust can be diverted to compressor suction or used as fuel. This means wet air is vented without requirement of separate drain or electrical power.
Water Chilling Plant
Get Price Quote
We manufacture water chilling plants with nominal cooling capacity for Plastic products Industries. The system of water chilling plant is to deliver chilled water to the end user. Cooling Capacity : 2TR, 3TR, 5TR, 10TR and more.. Salient Features : Emerson climate Technologies/Danfoss make compressor. Available Hermetic Compressor or scroll Compressor. Air cooled type condenssor with Axial Fan. Shell and tube or Copper pipe type cooling Unit Schneider make Electrical components. Digital temprature Controller. Stainless stell with Insullation water Tank.(Avialable- 2TR, 3TR, 5TR, 10TR) Inbuilt water Chillig pump.