Portable Tritium in Air Monitor
Get Price Quote
Air Quality Monitor
Get Price Quote
AIR-300: The AIR-300 is a microprocessor based air quality monitor/controller sensitive to a wide variety of air pollutants. FEATURES True Air Quality Monitor Microprocessor based controller Analog Stepped Output (ASO) 10 bit resolution Able to detect one in 15 m3 (530 cu. ft.)room Integral sensitivity adjustment Ability to directly control air handling unit Visual indication of air quality (internal) APPLICATIONS Schoolrooms Office buildings Parking garages Washroom ventilation fans smoke detectors DESCRIPTIONThe AIR-300 is a microprocessor based air quality monitor/controller utilizing a hot wire element sensor based upon the Taguchi principle. This is a full spectrum sensor sensitive to a wide variety of air pollutants such as carbon monoxide, smoke, benzene, alcohols, hydrogen, hydrocarbons, esters, etc.This sensor is better suited to measuring air quality than a sensor which measures only Carbon Dioxide. The AIR-300 yields a true indication of the actual air quality, rather than occupancy. For example, if a person were to smoke a in a room, the carbon dioxide sensor would be inadequate in detecting this, even though the air quality had significantly degraded. This same set of circumstances holds true for many other contaminants such as Solvents, Fuels, and even Carbon Monoxide, all of which are much more harmful than Carbon Dioxide.When measuring Air Quality, it is not so much the type of contaminant that is of concern, but rather the presence of any contaminants. This sensor does not indicate which contaminant is in the air, but indicates the presence and quantity of any contamination.The Greystone AIR-300 monitor/controller works by looking at the signal from a full spectrum sensor, automatically compensating for temperature and humidity effects, and judging the degree of pollution. For the unit to perform efficiently it must work as a monitor/controller, i.e. it must be able to act upon level changes. The output is represented as an analog, stepped or relay output with user adjustable settings. This output can be used to directly control an actuator, or be sent back to a Building Automation System (BAS).The AIR-300 can be configured to run in auto or manual mode and has an integral sensitivity adjustment to provide the user with the optimum settings to monitor a specified area. There are internal LED indicators to show microprocessor status and also a manual override feature to assist in installing the unit.
Best Deals from Air Monitors
AIR MONITOR
Get Price Quote
An Industrial Blower or Centrifugal Blower typically has one of seven types of wheels that draw the air into the inlet of the blower housing while an Axial Flow Fan or Industrial Axial Fan uses a propeller to draw the air into it. The air in and industrial or centrifugal blower is drawn through the wheel, and discharged at 90 degrees out through the discharge of the housing. An axial flow fan discharges it in the same axial direction. Fans are air-moving devices with propellers while blowers are those with a wheel. Leaks are a significant source of wasted energy in a compressed air system, often wasting as much as 20-30% of the compressor's output. Compressed air leaks can also contribute to problems with system operations, including: Fluctuating system pressure, which can cause air tools and other air-operated equipment to function less efficiently, possibly affecting production Excess compressor capacity, resulting in higher than necessary costs Decreased service life and increased maintenance of supply equipment (including the compressor package) due to unnecessary cycling and increased run time
Continuous Air Monitor
Get Price Quote
Continuous particulate air monitors have been used for years in nuclear facilities to assess airborne particulate radioactivity (APR). In more recent times they may also be used to monitor people in their homes for the presence of manmade radioactivity. These monitors can be used to trigger alarms, indicating to personnel that they should evacuate an area. Our low profile fixed filter monitor designed to continuously collect and measure the quantity of radioactive beta particulates or gamma iodines in the sample stream. The system will monitor radioactive airborne levels in either working spaces, or via a process tubing connection to a remote stack, duct or other air space. SYSTEM FEATURES: System Skid Assembly, fully wired & plumbed. Measurement of alpha and/or beta particulate. Beta Scintillation Detector or Gamma Scintillation Detector. Isotopic Check Source (optional). Detachable head assembly for remote monitoring. Fixed filter or moving filter configurations available. Full alpha spectral analysis with unique radon-thoron peak fitting algorithm. Preamplifiers/HV Supply. Display and Control Units.
air monitors
Get Price Quote
air monitors
Get Price Quote
air monitors, Digital Flow Meter, PD Flow Meter
Air Pollution Monitoring
Get Price Quote
Air Pollution Monitoring, Gaseous Sampling Attachment