  • Ambient Air Quality Monitoring System

    Ambient Air Quality Monitoring System

    105,000 Per Piece

    • Voltage: 220V
    • Automatic Grade: Automatic
    • Power: 1-3kw
    • Driven Type: Electric
    • Sensor Technology: Light Transmission
    • Display Type: Digital
    more..
  • Portable Tritium in Air Monitor

    Portable Tritium in Air Monitor

    Get Price Quote

    • Accuracy: ±3µCi/m³ from 1 to 100µCi/m³, ±10% from 100µCi/m³ to 20,000 µCi/m³
    • Range: 1 µCi/m³ to 199,999 µCi/m³
    • Power Supply: 2.5 V- 5V external power supply, or 3 C-cell battery. Total power consumption is 150mA.
    • Response Time: 30 seconds at 90% of signal
    • Sensitivity: 1µCi/m³ ( 0.05 DAC)
    • Detector: 4 matched chambers - Two for measuring, two for compensation
    • Measuring chamber effective volume: 500 cc (2 measuring chambers of 250cc each)
    • Flow rate: 1.0 L/m
    • Zero stability: ±1µCi/m³ immediately after unit is powered on
    • Background cancellation: Less than 10% of the reading change in 20 mR/hr field
    • Radon compensation: Included in the software
    • Ion trap: Built into each ion chamber
    • Dust filter: Built into the unit.
    • Noble gas cancellation: Ports for air inlet/outlet of measuring chambers and compensation chambers are accessible on surface plate so silica gel drier can be placed between the chambers to compensate for presence of noble gas.
    • Tritium Discrimination: Instrument can discriminate in a field of HTO and elemental H3 using the silica gel drier.
    • Purge/Decontamination: All 4 Chambers can be heated up by a cartridge heater controlled by unit
    • Display: Graphic touchscreen LCD display. Unit displays the values(tritium and Gamma) both in numerical format and graphical trend.
    • Communication: Can be configured to RS232(Short distance) or RS485(Long distance).
    • Analog output: 0-5 V Linear or logarithmic voltage output.
    • Gamma measurement: Gamma is measured directly by the unit. Gamma measuring range is from 0.1mR/h to 10R/h
    • Alarm: Tritium alarms, gamma alarms, low air flow alarms will all be shown by red LED light and by an audible device.
    • Data logging: The tritium and gamma values are logged every minute with current time and date stamp
    • Size and weight: 8"(L)x5"(H)x5"(W), 7 lbs.
    • Drier: Note that the silica gel drier is not part of the standard equipment, but can be supplied as an extra.
    more..
  • Best Deals from Air Quality Monitors

  • Air Quality Monitor

    Air Quality Monitor

    Get Price Quote

    AIR-300: The AIR-300 is a microprocessor based air quality monitor/controller sensitive to a wide variety of air pollutants. FEATURES True Air Quality Monitor Microprocessor based controller Analog Stepped Output (ASO) 10 bit resolution Able to detect one in 15 m3 (530 cu. ft.)room Integral sensitivity adjustment Ability to directly control air handling unit Visual indication of air quality (internal) APPLICATIONS Schoolrooms Office buildings Parking garages Washroom ventilation fans smoke detectors DESCRIPTIONThe AIR-300 is a microprocessor based air quality monitor/controller utilizing a hot wire element sensor based upon the Taguchi principle. This is a full spectrum sensor sensitive to a wide variety of air pollutants such as carbon monoxide, smoke, benzene, alcohols, hydrogen, hydrocarbons, esters, etc.This sensor is better suited to measuring air quality than a sensor which measures only Carbon Dioxide. The AIR-300 yields a true indication of the actual air quality, rather than occupancy. For example, if a person were to smoke a in a room, the carbon dioxide sensor would be inadequate in detecting this, even though the air quality had significantly degraded. This same set of circumstances holds true for many other contaminants such as Solvents, Fuels, and even Carbon Monoxide, all of which are much more harmful than Carbon Dioxide.When measuring Air Quality, it is not so much the type of contaminant that is of concern, but rather the presence of any contaminants. This sensor does not indicate which contaminant is in the air, but indicates the presence and quantity of any contamination.The Greystone AIR-300 monitor/controller works by looking at the signal from a full spectrum sensor, automatically compensating for temperature and humidity effects, and judging the degree of pollution. For the unit to perform efficiently it must work as a monitor/controller, i.e. it must be able to act upon level changes. The output is represented as an analog, stepped or relay output with user adjustable settings. This output can be used to directly control an actuator, or be sent back to a Building Automation System (BAS).The AIR-300 can be configured to run in auto or manual mode and has an integral sensitivity adjustment to provide the user with the optimum settings to monitor a specified area. There are internal LED indicators to show microprocessor status and also a manual override feature to assist in installing the unit.

    more..