Industrial Fire Alarm Control Panel
40,000 Per Piece
Fire Alarm Repeater Panel
Get Price Quote
100 Piece (MOQ)
Best Deals from Alarm Panels
Fire Alarm Panel
Get Price Quote
SILITRONIX manufactures "Smoke Detection & Fire Alarm Systems / Panels" since 1985 as per IS 2189. Our Fire Alarm panels are approved by P & T, TAC, ETDC , ONGC, Bank like SBI e.t.c. Our Micro Controller Based Fire Alarm Panel is design to includes Latest Low Power consumption available Technology offering many features in Slim & most compact size. We also manufacture premium Modular type Fire Alarm Panel, which is made from premium quality materials and are available in wide range to cater to different fire safety needs of our clients. SILITRONIX Fire Detection & Alarm Panels can be Useful at many Public / Private Places where “ Fire Protection “ is required. Technical Specifications Of Modular Fire Alarm Panel : Input Supply : 230 V A.C. / 24 V D.C. Modules : Fire Alarm Panel Includes Different Types Of Plug in Modules, Performing Different Operations : Meters : Three Analogue Meters are Provided :A.C. Volt Meter , Showing Input Mains Supply.D.C. Volt Meter, Showing 24 V D.C. Feeding to Detector system.D.C. Ampere Meter , Showing Battery Charging Current in Ampere. MCP : It Includes 24 V D.C. & 12 V D.C Regulated Power Supply & Automatic Battery Charger & Battery Backup Circuits.LCP : It Includes Inverter for Control Power Supply ±12 V D.C., Hooter Circuit, Fire Alarm LED Flasher Circuit, Silence / Reset Audio Alarm , Buzzer Fault Alarm etc.Dual Zone Card : Each Card includes / Represent Two individual Room / Hall / Area for FIRE & FAULT indications. Its circuit is Connected with series of Detectors of one Particular Area / Zone. It continuously watch Detector Signal. If it Finds some abnormal condition in Input Signal, it Indicates by different coloured LEDs glowing as Under. Indications : FIRE : Two Red LEDs Glow with Flashing ,Sending actuation Signal to Common Audio Buzzer & Hooter Alarm Circuit. Which also Field Hooters of that area which gets FIRE.FAULT : When Input Circuit Finds No signal from Detector, It In As a Open Circuit Glowing Green LED, Sending Signal To Audio / Buzzer Alarm. When Input Circuit Finds SHORT CIRCUIT signal from Detector, It Indicates As a SHORT Circuit, Glowing Yellow LED Sending Signal To Audio / Buzzer Alarm.ISOLATE : When any Zone / Area gets some Fault Signal, after Acknowledging it, till You Repair / rectify it, You can Isolate that effected Zone by Toggle Switch. Switches : On Each Zone Card , Test Switches are provided to Test / Stimulate the Health ness Of Total Systems in FIRE, OPEN, SHORT Conditions.SILITRONIX Also manufactures Slim & Most Compact Micro Controller Based Fire Detection & Alarm Panels for 1 zone 32 Zones in the Same Model. Applications : SILITRONIX Fire Detection & Alarm Panels can be Useful at many Public / Private Places where FIRE PROTECTION is required. A Hotel to A GodownA Bank to A FactoryPower Station to A RefineryA Record Room to A LibraryA Computer Center to A Telephone ExchangeAnd Many Many other Public Dealing Buildings & Premises Technical Specifications Of Micro Controller Based Fire Alarm Panel : SILITRONIX Also manufactures Slim & Most Compact Micro Controller Based “ Fire Detection & Alarm Systems “ from 1 zone To 16 Zones in the Same Model using Scanning Multiplex Technology. Its brief technical details are as under.Digital Display : Our Fire Alarm System consist of two Digit Display.Zone No. Display : It is a Two digit display , showing Zone No. advancing 1 To 16.Fault Message Display : It is a four digit display showing Four types Of fault Messages for each Zone as “ Fire “, “ Open “, “ Short “, “ Good “.Key Board : Four Keys are provided for easy & friendly Operations. Function Key : It is used to select four different Functions / Operations as Selection of Maximum Zone Operation ranging 1 To 16 Nos.Time Delay between two Zone display ranging 2 To 9 Second.Scanning On / Hold selection. If Hold function is Selected , then select Zone No. which will Continuously showing that Selected Zone No. with Its Fault Status.By this, Buzzer Operation is selected – Continuously ON in case of any “ Fault “ in any Zone or Buzzer ON while that Faulty Zone No. display. Up / Down Key : By means of this Key operation , channel No., Time Delay etc can be change. Enter Key : By means of this key , any data / parameter which is selected is saved. Buzzer Acknowledgement : If any “Fault “ occurs in any of the Zone , Buzzer will ON. This Buzzer can be “ Silent “ by pressing this key. LED Indications : Four Arrays Of Different Coloured LEDs are provided for each Zone, showing Its fault status as under.Fire, Open, Short, Good. Features : SILITRONIX can cater Excellent & Intelligent features & Facility to a varied needs of valued Customers on demand.In case of some emergency / fire , automatic Telephone dialing system at selected number will be provided On demand.Computer Interface facility with data Logging System Using Serial data Communication – RS 485.Key Board “ Password “ facility will be provided on Demand for security purpose.SILITRONIX also manufactures other Fire / Emergency Alarm System Related Items as under. Manual Emergency Alarm Panel : It is a wall Mounting Type, Audio / Visual Manual Alarm systems. It actuates by Break Glass of Manual call Point keep at Each Wing of Floor. As soon as Break of any manual Call Point connected with Panel on any Floor, Dual Flashing “ Fire / Emergency Alarm ON “ LEDs Glow On Panel, with inbuilt Audio Hooter / Alarm ON. Also all External Hooters ON / Sounds Keep at Each Floor. Audio Alarm can be Silence / by Switch Operation. A Manual Test" Facility is also provided, Which actuates Alarm system with all Hooter ON. Applications : High Rise Buildings use as office Complex , Residence Complex, Multiplex Theaters, Shopping Mole etc. Accessory : SILITRONIX offers accessory useful with Fire Alarm Panels. Its brief descriptions are as under. Hooters : It is a wall Mounting Type solid state Audio alarm System. There are two types of Hooters available . Speaker Based wall mounting type cabinet with inbuilt Electronic circuit. It Operates from 24 V D.C. with Vouling type Sound. It creates more than 60 DB Sound.Horn Based wall mounting type with Tilting Clamp, By which you can set the direction of Sound. Its Operating voltage is 15 V To 20 V D.C. It generates Vouling type Sound which can be listen far more than 100 Feets.Manual Call Point : It is a wall Mounting Type Break Glass Instrument. If its glass is break. It sends a signal to the panel to actuates a Alarm Circuit in the Panel & two Red Colour LEDs Glow on this Box.Response Indicator : It is a wall Mounting Device having Two LEDs. When It gets signal from Detector , this Two LEDs start to glow. It operates from 24 V D.C
Fire Alarm Control Panel
5,000 Per Piece
alarm control panels
Get Price Quote
Fire Alarm Control Panel
350,000 Per unit
1 unit (MOQ)
Fire Alarm Panel
Get Price Quote
Fire Projects relay on Ravel for conventional fire alarm panel. The RE-2554/8 is a 4/8 zone UL Listed Conventional Fire Alarm control Panel. These control panels are designed to be used in small & medium commercial industries, buildings, hotels, schools, etc. and are compatible with conventional detectors, manual call points and normally open dry contact devices. Fire projects recommend Ravel RE-2554/8 conventional fire alarm control panel which has been designed to comply NFPA-72 guideline and other local codes. Fire alarm control panel is self-contained with integral power supply and space provision for two sealed lead-acid standby batteries. Ravel fire alarm control panel control function with microprocessor and test and isolate functions are included. It enable repeater function of panel status output. RE-2554/8 has optional function of RS 485 communication facilities along with lamp test and walk test. Fire Projects has succesfully programmed Ravel Re-2554/8 for NAC's, IDC's, Trouble reminder, Earth fault annuciation, Supervisory mode with alarm verification facility. Conventional Ravel RE-2554/8 fire alarm control panel installed by fire projects, receive information/signal from field devices called smoke detector, heat detector, beam detector, ultra violet flame detector for fire detection and fire alarm control panel start giving alarming. Conventional Ravel RE-2554/8 fire alarm control panel required local power supply and it provide electrical energy to field devices as well as signaling devices called manual call point and sounder, hooter or sounder with flash.   We support our clients from Designing up to Commissioning to AMC. We also provide AMC–Annual Maintenance Contracts for all types of Fire & security Systems. If you required new installation or AMC of fire alarm system, contact Fire Projects today!
Intelligent Fire Alarm Control Panel
Get Price Quote
Single loop addressable fire detection panel packed with features not usually associated with smaller systems, providing a high quality solution at exceptionally good value. Loop capacity 235 intelligent devices Graphical LCD display 30-zone indication and manual intervention panel Fire and fault relay output 2 bell circuits Net-workable with all GST fire panels Programmable from PC Built-in gas extinguishing control Integrated security alarm facilities Optional color graphics Optional fireman control panel Optional panel printer Advanced user friendly programming software including fuzzy logic Technical Specifications Power supply: 230VAC 5060Hz Operating Environment: Relative humidity: 95% Dimensions (L x W x H): 400mm x 182mm x 560mm
WIRELESS SECURITY SYSTEM - Alarm Control Panel
Get Price Quote
 GSM remote control to Arm/Disarm alarm system, auto-gate,lightings etc.* User friendly operation.* Alarm reporting through GSM network.* One touch emergency dialing.* LED zone/sensor indicators to allow seeing zone status from distance.* 8 wireless zones and 4 wired zones.* Built-in rechargeable battery allowing 24 hours backup power to the system.* Hand free two ways voice communication during medical alert activation.
zone fire alarm panel
Get Price Quote
* Compatible to all types of conventional detectors* Hooter loop monitoring facility* Twin RED LED indication for fire* Zone Disable (Isolation) facility with loop voltage cutoff* Relay output for actuators* Resettable 24V DC output for4wire detectors (Optional)* Battery backup with built in charging
Manual Fire Alarm Control Panel
35,000 Per Piece
1 Piece (MOQ)
Fire Alarm Control Panel
Get Price Quote
The Morley-IAS DX Connexion panel is ideally suited for use in the protection of small to medium sized buildings. All in all, a compact, high performance, feature rich, economical fire alarm control panel designed to help both the installer and the end user.The DX Connexion is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality. The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. Simply fix the control panel to the wall, connect the field wiring, power up and in as few as five button presses you can have a compliant, working fire alarm system. The panel’s large graphical display provides a clear menu structure making the whole initial set-up process quick, clear and intuitive. DXc range Morley-IAS addressable fire alarm control panels are available with large blue LCD display and support user to create 40 to 80 zone alarm with option to upload company logo.  DXc1 (1 Loop fire alarm control panel) , DXc2 (2 Loop fire alarm control panel) and DXc4 (4 Loop fire alarm control panel) addressable fire alarm control panel supports Apollo (Xplore, XP95 and Discovery), Hochiki (ESP) & System Sensor protocol devices. Additionally, programming the control panel couldn’t be easier. Complex configuration can be achieved by using either the panel’s mobile phone style key pad or by using the Windows PC programming tool supplied with the panel. The flexible PC programming tool also allows text messages for devices or zones to be imported from an Excel spread sheet, saving further time. + User Interface:  • Display: 6x40 character (240x64 pixels) blue liquid crystal display with backlight illumination • Control Keys: Evacuate, Silence/Resound, Mute Buzzer, Extend Delay, System Reset, Show Alarm Zones • Programmable Keys : 2 independent programmable function keys and LED indicators • Programming Keys : 12 button alpha numeric key pad inccluding cancel and return keys plus 4 navigation keys and an OK key • Indicators: Fire, Fault, Disablement, Test, Buzzer Muted, Delayed Mode, Sounders Silenced, sounders Disabled and Power. Also dedicated fault LEDs for System Fault, Supply Fault and Earth Fault. 40 or 80 LED fi re zone indicators optional.  + Networking Features:  • Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) • True peer-to-peer and fault tolerant network for high system reliability • BS5839 part 1 compliant network  + Panel Features:  • Optional 40 or 80 zone alarm LEDs • Easy 5 key-press set-up • Large blue LCD display • Supports USB upload/download • Mobile phone style keypad and navigation keys • Option to upload a company logo  + Software Features:  • PC confi guration software (supplied with panel) • 80 fi re zones (can be used with or without LEDs) • 7 day timers • Event logging • Onboard diagnostics • Class change function • Coincidence and verifi cation detection for false alarm management • Sensitivity adjustment e.g. between day and night • Input/output logic  + Hardware Features:  • Battery backed real-time clock (2 & 4 loop) • 2 independent sounder circuits • 500mA multi-protocol loop driver • 2 x onboard monitored inputs • Optional programmable keyswitch for selected functions • Plug-in connectors
Fire Alarm Panel
Get Price Quote
Product Description: Being a prominent organization, we are instrumental in providing our valued clients with a wide assortment of Fire Alarm Panel. Features: Extremely durable Precise design High strength
Atman Alarm Panels
Get Price Quote
1 Piece (MOQ)
Fire Alarm Control Panel
Get Price Quote
Fire•Lite’s MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Control Panels). The combination of Fire•Lite’s newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLSE FACP, offer the latest in fire protection technology. LiteSpeed™ is a patented technology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the system polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification circuits in under 10 seconds. With this new polling scheme, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Circuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules. User Interface:  • Optional plug-in DACT-UD2 communicator (standard with MS-9600UDLS(E) with USB port for local upload/download. • Remote Acknowledge, Silence, Reset and Drill via addressable monitor modules, ACS Series annunciators, LCD-80F remote annunciator, or ANN-80 Series Annunciators. • EIA-232 printer/PC interface (variable baud rate) on main circuit board. • Integral 80-character LCD display with backlighting. • Real-time clock/calendar with automatic daylight savings adjustments. • History file with 1,000-event capacity. • EIA-485/ANN-BUS supporting up to 8 ANN Series Annunciators or 32 ACS Series annunciators. • EIA-485 supporting up to 32 ACS annunciators. • Maintenance alert warns when smoke detector dust accumulation is excessive. • Automatic device type-code verification. • One person audible or silent walk test with walk-test log and printout. • Point trouble identification. • Local piezo sounder. • Waterflow (nonsilenceable) selection per monitor point. • System alarm verification selection per detector point. • PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant).  Special Features:  • Easy mount chassis. • 7 amp switching power supply. • Large enclosure allows 18 amp-hour batteries • DACT-UD2 plug-in communicator standard with MS-9600UDLS/E. • Optional IPDACT Internet Protocol Digital Alarm Communicator/Transmitter • Four Style Y (Class B) or two Style Z (Class A) NAC circuits. • Selectable strobe synchronization per NAC for System Sensor, Wheelock, and Gentex devices. • Automated control of ACC-25/50(ZS/T) audio speaker circuits • ANN-BUS for connection to following optional modules Note: cannot be used if ACS annunciators are used. • ANN-80(-W) Remote LCD Annunciator • ANN-I/O LED Driver Module • ANN-S/PG Serial/Parallel Printer Module • ANN-RLY Relay Module • ANN-LED Annunciator Module • ANN-RLED Annunciator Module (alarms only)
Fire Alarm Panel
Get Price Quote
Fire Alarm Panel, Motor Control Centre, Power Distribution Panels
Fire Alarm Control Panel
Get Price Quote
Fire Alarm Control Panel, Brass Tongue Cleaner, Frozen Kachori
repeater panel
Get Price Quote
repeater panel, B TAP Insulation Piercing Tap Connectors
Fire Alarm Panel
Get Price Quote
Fire Alarm Panel, Alarm System, alarm system and industrial hooter
Fire Alarm Addressable Panel
Get Price Quote
Fire Alarm Addressable Panel, Projection Screen, Connectors, Speakers