Drive Panel Dealers in Odhav, Ahmedabad

(19 products available)
  • Drive Panel

    Drive Panel

    Get Price Quote

    • Max. Power:: 70 W
    • Power Range:: 800 Kw - 500 Kw
    • Output Voltage:: 200 V - 240 V

    DESCRIPTION: We are a noteworthy organization devotedly engaged in offering wide gamut of Drive Panel. The offered panel is manufactured using superior quality components and innovative technology in line with industry norms. We offer this panel to our customers after testing it against different parameters. Moreover, this panel is available in variegated designs and specifications as per the customers’ demands at market leading prices. FEATURES: Long lasting service life Smooth finish Low power consumption SPECIFICATIONS: Max. Power: 70 W Power Range: 800 Kw - 500 Kw Output Voltage: 200 V - 240 V

    more..
  • Variable Frequency drive panels

    Variable Frequency drive panels

    100,000 Per Set

    1 Set(s) (MOQ)

    • Type: Drive Panel
    • Application: Indutrial Use
    • Weight: Depends
    • Condition: New
    • Input Voltage: 440V
    • Body Material: Mild Steel
    • Power: up to 250 HP
    • Driven Type: Electric
    • Phase: Three Phase
    • Warranty: 1yr
    • Brand Name: DYNAMIC
    • Quality: As Required
    more..
  • Best Deals from Drive Panel

  • ac drives panel

    ac drives panel

    Get Price Quote

    Dust & Vermin proof Cooling fan/A.C. Attachment Spacious for Maintenance free Wiring diagram fixing at panel Door Proper Space for Cable termination Easy for Ready to use AC Drives from 0.25 HP to 300 HP Application with Vector/Winder control Remote Operation/Local Control Speed/Amp./Rpm Display At Panel High torque/Smooth variation of speed Reliable Drive at Competitive Price Available protection IP54, IP55 / IP64, IP65

    more..
  • Ac Drive Panel

    Ac Drive Panel

    Get Price Quote

    Adjustment of the speed of the motor is the application, which is required in all the process industries & machinery Mfg.'s. Variable Frequency drive is used as energy saving device for some of the machines to save power during no load or it is used as final control element of the closed loop control application where the speed of the motor is changed to control one parameter. Some of the application is provided with manual speed control of the motors. These are the open loop control applications

    more..
  • Drives Control Panels

    Drives Control Panels

    Get Price Quote

    We are offering our valued customers with highly efficient Drives Control Panels. These Drives Control Panels are integrated using high-grade component that ensure satisfactory performance for long life. Further, our Drives Control Panels are quality-certified, signifying their excellent performance. Highlights : Longer service lifeNon-corrosive housingAssembled using high-end componentsCompact designAvailable in different specifications

    more..
  • Variable Frequency Drive Panel

    Variable Frequency Drive Panel

    Get Price Quote

    • Weight: 0-25kg
    • Voltage: 440V
    • Power Type: AC, DC
    • Frequency: 50Hz
    • Phase: Double Phase, Three Phase
    • Warranty: 1Yr

    VFD Panel WorkingVFD Panel full form is Variable Frequency drive panel also known as VFD Control Panel. Variable Frequency drive panel designed to control the speed of electric motor and feed pump. VFD and soft starter are widely used in drilling, pumping and other large machine applications..The VFD panels widely used in tube mills, paper mills, extruder plants, rolling Mills, cable industry and CTL Lines. Also VFD panels installed in hospitals, business houses and other public places.Protection LevelFirstly, all indoor panels have protection of IP54 or better even more all outdoor panels have protected with IP65 or better. Secondly, all PCC Panels made by laser cutting CRCA sheet and powder coating with 7-Tank process.IntroductionWe Accu-panels are the premier organization engaged in manufacture and supply of incredible range of Variable Frequency Panels (VFD) and SOFT Starter Panels. These panels, also known as digital VFD drives play an important function in VFD squirrel cage induction and in motor control applications.Features Firstly Safe Secondly Durable Thirdly High performance Also Sturdy construction and Finally Corrosion resistance SpecificationsA soft starter have solid-state device that protects AC electric motors from damage caused by sudden influxes of power by limiting the large initial inrush of current associated with motor startup. They provide a gentle ramp up to full speed and are used only at startup (and stop, if equipped). Ramping up the initial voltage to the motor produces this gradual start. In Conclusion, Soft starters also known as reduced voltage soft starters (RVSS).Applications Soft starters are used in applications where: Speed and torque control required only during startup (and stop if equipped with soft stop) Reducing large startup inrush currents associated with a large motor The mechanical system requires a gentle start to relieve torque spikes and tension associated with normal startup (for example, conveyors, belt-driven systems, gears, and so on) Pumps used to eliminate pressure surges caused in piping systems when fluid changes direction rapidly

    more..
  • AC Drive PLC Control Panel

    AC Drive PLC Control Panel

    Get Price Quote

    We have a modern warehouse equipped to store a variety of products in bulk amount. Besides our wide distribution network, our warehouse enables us to maintain year round availability of products.We have a modern warehouse equipped to store a variety of products in bulk amount. Besides our wide distribution network, our warehouse enables us to maintain year round availability of products.We have a modern warehouse equipped to store a variety of products in bulk amount. Besides our wide distribution With the aid of our well-established network and cordial associations, we are able to cater to the wide requirements of the buyers based in Ahmedabad(India).

    more..
  • Ac Drive Panel

    Ac Drive Panel

    Get Price Quote

    When a VFD starts a motor, it initially applies a low frequency and voltage to the motor. The starting frequency is typically 2 Hz or less. Starting at such a low frequency avoids the high inrush current that occurs when a motor is started by simply applying the utility (mains) voltage by turning on a switch. When VFD starts, the applied frequency and voltage are increased at a controlled rate or ramped up to accelerate the load without drawing excessive current. This starting method typically allows a motor to develop 150% of its rated torque while drawing only 50% of its rated current. When a motor is simply switched on at full voltage, it initially draws at least 300% of its rated current while producing less than 50% of its rated torque. As the load accelerates, the available torque usually drops a little and then rises to a peak while the current remains very high until the motor approaches full speed. A VFD can be adjusted to produce a steady 150% starting torque from standstill right up to full speed while drawing only 50% current.

    more..
  • Dc Drive Panel

    Dc Drive Panel

    Get Price Quote

    Power Control Centre is considered to be the heart of an electrical system in any industry. Therefore it shall offer users long-term reliability, safety, low maintenance testing time. A few of the salient feature of our DC Digital Drive Panel includes: Single quadrant and four quadrants drive options Full control three phase interchangeable thyristor bridges Drive status indications Input AC supply variations up to + 15% permitted Maximum operating temperature 60 degree Celsius Speed Control Range 1:100 with tacho feedback Steady state accuracy with encoder Tacho and arm volt feedback option Overload capacity 150% rated output current for 25 seconds 36 digital input I/O combination Unique Inbuilt shaft position controller Intelligent Overload Protection Large 40Character alphanumeric display Ultra Compact size –Less Panel space Inbuilt Surge Voltage Suppression Inbuilt Single Phasing Protection Adjustable Current Limit 0-200% Protection features of DC drives: Instantaneous over current Field failure protection in DC Drive card Field Over current Motor over-temperature Thyristor stack Over-temperature Mains supply phase loss Mains synchronization loss Armature over voltage in DC Drive feedback card Thyristor Trigger failure option in DC Drive Over speed Tacho and/or encoder failure with auto change-over to arm voltage feedback All analog and digital outputs are short circuit protected. Backed by huge industry experience and market understanding, we are involved in offering a wide array of DC Drive Panel for our valued patrons.

    more..
  • AC VARIABLE DRIVE CONTROL PANEL WITHOUT COMPUTER

    AC VARIABLE DRIVE CONTROL PANEL WITHOUT COMPUTER

    Get Price Quote

    • Indication: R,Y,B Phase indication will be provided.  Control ON indication will be provided. Motor ON indication will be provided for each motor.  Empty Bin indication will be provided for each Bin.

    Fether touch control will be provided for smooth operation of plant.   General feature:- User friendly As per M.O.S.T. Fully auto microprocessor based technology Best quality of product Easy to operate   Display System :-   Product Rate Display shows the present Ton / Hour (TPH) capacity of the plant. Display shows :- set percentage of each Bin Master setting. Set & actual    aggregate TPH, percentage of Bitumen, percentage of filler. Actual percentage & kg/min of Bitumen and filler. Percentage of set moisture.   Total Display shows total tones of Aggregate, total kg of Bitumen, total kg of Filler. It also shows tones of Net mix material.   Temperature :- ( Microprocessor based Temperature controller)   Display shows  actual temperature and set temperature of Bitumen Tank -1 temperature, Bitumen Tank -2 temperature, Mix material temperature, Aggregate temperature.   High temperature & Low temperature facilities will be provided by control of  Nozzle of dryer burner.   Mimic System :- Mimic display    shows  indication of running mode or OFF mode of any motor. Whether the plant is in running mode or not is varified from the mimic display.   Hopper Function ( Micro processor based ) :- Setting of :- open time of Hopper close time of Hopper hold on time of Hopper   It also shows display of above parameter. Hopper can also be controlled manually from feather touch control.   Printer:- Wipro make printer will be provided.  Printout facilities will be provided for current material use for production.  In print out the following parameters will be printed.  

    more..
  • Ac Drive Panel

    Ac Drive Panel

    Get Price Quote

    • Power: 0.25 HP to 300 HP

    Cooling fanA.C. Attachment, Spacious for Maintenance free, Wiring diagram fixing at panel Door, High torqueSmooth variation of speed, Remote OperationLocal Control, Available protection IP54, IP55 IP64, IP65.

    more..
  • Ac Drive Panel

    Get Price Quote

    A well known A C Drive Panel supplying company.

    more..
  • Drive Panel

    Get Price Quote

    We offer drive panel bord.

    more..
  • Drive And Control Panel

    Get Price Quote

    Drive And Control Panel, Motor Control Panel, Control Panel

    more..
  • plc drive panel

    Get Price Quote

    plc drive panel, DG Set Control Panel, DCS Panel, low voltage panel boards

    more..
  • Drive Panels

    Get Price Quote

    Drive Panels, Energy Distribution Boards, Meter Power Panel

    more..
  • Drive Panel

    Get Price Quote

    Drive Panel, Automation Panel, Electrical Panel, PCC Panel

    more..
  • dc drives panel

    Get Price Quote

    dc drives panel, AC Drive > MFDDTB3A2 (5KW), ac drives panel, APFC Panel

    more..
  • Drive Panel

    Get Price Quote

    Drive Panel, Chemical Plant, Chiller Plant, Cold Storage

    more..
Filter by Locality
top