Temperature Data Logger
Get Price Quote
Float and Board Type Level Indicator
1,000 - 100,000 Per Piece
10 Piece (MOQ)
Level indicators, unlike level switches, provide a continuous visual representation of the level of liquid or bulk solids within a container. They offer a more informative way to monitor fill levels compared to level switches that simply trigger an on/off signal at preset points. Here's a breakdown of level indicators and their various types: Function: · Provide a direct visual indication of the level of liquid or bulk material in a tank, bin, or silo. · Allow for continuous monitoring of fill levels without relying solely on electrical signals. · Can be used for various applications, including process monitoring, inventory control, and ensuring safety by preventing overfills. Types of Level Indicators: The choice of level indicator depends on the type of material being monitored (liquid or solid) and the desired level of detail: · Sight Glasses (Tubular Level Gauges): o Simple and cost-effective option for liquids. o Consists of a transparent tube or window mounted on the side of a tank, allowing you to see the liquid level directly. o Suitable for various tank sizes and pressures depending on the material. · Reflex Level Gauges: o For liquids with different refractive indexes (light bending properties) than the gauge material. o The interface between the liquid and empty space appears as a distinct line due to refraction, indicating the level. · Magnetic Level Indicators: o Utilize a magnetic float inside the tank connected to an external indicator with red and white sections. o The red section rises with the float as the liquid level increases, providing a visual indication. (May not be suitable for all liquids or environments with strong magnetic fields) · Electronic Level Indicators: o Employ electronic sensors and a digital display to show the liquid level. o May use various sensing technologies like ultrasonic or radar and offer features like level scaling and data logging. · Float and Board Level Indicators: o Primarily for large tanks with bulk solids. o A float rides on the surface of the material, connected by a cable and pulley system to an indicator board outside the tank. o The board moves up or down to visually represent the fill level. Additional Considerations When Choosing a Level Indicator: · Material Type: Liquid or bulk solid (and its properties like transparency, viscosity)? · Tank Material and Pressure: Compatible with the sight glass or enclosure material? · Temperature Range: Suitable for the operating environment? · Desired Level Detail: Basic level indication or need for precise measurements? · Visibility Requirements: Viewing distance and ambient light conditions? · Cost and Maintenance: Evaluate initial cost and ease of cleaning or maintenance. Advantages of Level Indicators: · Simple and Easy to Use: Provide a clear visual representation of fill levels. · Reliable Operation: Generally less complex than level switches, offering reliable monitoring. · Cost-Effective: Many options are affordable, especially for basic level indication. Disadvantages of Level Indicators: · Limited Data Output: Do not typically offer data logging or remote monitoring capabilities. · Accuracy: May not be as precise as some electronic level switches for specific applications. · Visibility Concerns: Viewing angles or ambient light can affect readability in some cases. Overall, level indicators provide a valuable tool for visual monitoring of liquid or bulk solid levels in various applications. By considering the type of material, tank conditions, and desired level detail, you can choose the most appropriate level indicator for your needs. They offer a simple, reliable, and cost-effective way to keep an eye on your inventory and ensure safe operation.
Best Deals from Electronic Test Instruments
Winding Resistance Meter
Get Price Quote
1 Piece (MOQ)
Earth Testers - MODEL 4105A
Get Price Quote
Dust and drip proof.(designed to IEC 60529 IP54) In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories. (unit can be hung from the neck for simplified measurement) Designed to meet IEC 61010-1 safety standard. Capable of measuring earth voltage. Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance. Small and lightweight. Shock resistant new case material. 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test. Measurement ranges Earth Resistance: 0 - 20Ω/0 - 200Ω/0 - 2000ΩEarth Voltage [50,60Hz]: 0 - 200V AC Accuracy Earth Resistance: ±2%rdg±0.1Ω (20Ωrange)±2%rdg±3dgt (200Ω/2000Ωrange)Earth Voltage: ±1%rdg±4dgt Overload protection Earth Resistance: 280V AC for 10 secondsacross 2 of the 3 terminalsEarth Voltage: 300V AC for 1 minute Applicable standards IEC 60529 IP54 Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557 Power source R6 (AA) (1.5V) × 6 Dimensions 105(L) × 158(W) × 70(D)mm Weight 550g approx. Included Accessories 7095A (Earth resistance test leads) × 1set(red-20m, yellow-10m, green-5m)8032 (Auxiliary earth spikes) × 1set7127A (Simplified measurement probe) × 1setR6 (AA) × 69121 (Shoulder strap)Instruction ManualCarrying case : 9084(Carrying case[Soft]:4105A only): 9165(Carrying case[Hard]:4105A-H only) Optional Accessories 7100A (Precision measurement cord set)
Data Loggers
Get Price Quote
Pro_tek range of Advanced Power conditioner Series introduces Pro_tek CVT. These CVT are specially designed for their best performance to Indian power conditions. General specifications Power supply : 210 – 250 Volts 50 hz. Power consumption : 15 Va ( max.) Size : 190 mm L X 95 mm W X 210 mm D Weight : @ 2.0 Kg Operating temperature : 20 – 50 degree centigrade Measurement function PARAMETER : Voltage / Current / Power factor ( star model) SYSTEM : digital sampling , Typical r.m.s measuremetnt and averaging samples. VOLTAGE : 0-500 volts accuracy : .5 % to 1 % of reading CURRENT : 5 Amp through CT can be defined multification factor during initial setup TIME : True Real Time Clock DATA LOG.INTERVAL : Can be set from 1 min to 60 Min. INTERFACE : Through RS-232 , dedicated software to analyze values , can be transfer to Microsoft excel Report : data , graphical
Counter Type Energy Meter
Get Price Quote
FEATURES => State of Art Microcontroller Based Design.=> 7 Digit Stepper motor counter=> CT Ratio Site Programmable trough DIP switch=> True RMS measurement.=> Reverse indication for wrong wiring polarity=> Direct Reading No multiplication factor
Electromagnetic Sieve Shaker
Get Price Quote
We are the main supplier of this product.
analog panel meters
Get Price Quote
analog panel meters, Digital Panel Meters, process transducers
Energy Management System
Get Price Quote
L and T-Powerman offers sophisticated system for Monitoring & Managing Energy Consumptions by Electricity, Water & Gas. It can be integrated with ACBs, MCCBs, Meters & PLCs. Remote real-time monitoring & data acquisition. Intuitive Windows based Graphical User Interface (GUI).
MICRO CONTROLLER BASED CONDUCTIVITY METER
Get Price Quote
MICRO CONTROLLER BASED CONDUCTIVITY METER designed to measure the specic conductivityof a solution using a conductivity cell. It enables to measure the conductivity directly on display. This instrument incorporates an integrated circuitry and thus the power consumption is very low.
Digital Flow Meters
Get Price Quote
Introduction :- Paddle type turbine flowmeters for various Liquids. Accuracy - +2% on full scale valve. Max operating Pressure - 10 kg/cm’ 4-20 mA output Mounting - Panel / Wall / Field mounted Versions Display - LED / LCD in one line / Two line Reading in LPS / LPM / M3 / hr Measure Flow Instantly(Velocity must be more than 0.5 m/sec.) Material - pp/ms/ss pipe and turbine is in pp/ss(Teflonon request) Programmable Relay outputs Sizes - 12mm to 1200mm Max. operating temp - 70* C(For higher temp. sp.material acailable) Microprocessor based signal processing Also available with totallizer Routine tost of pump become very easy. Power Supply - 230 AC / 12V DC / 24V DC Measurement tank or “V” notch is not required. Very reasonable price & fast delivery.
Clamp Meter
13,784 Per Unit
5 Unit (MOQ)
Digital Ph Meter
Get Price Quote
Intelligent Panel Meter
Get Price Quote
Intelligent Panel Meter, Crompton Greaves Electric Motors
Thermal Conductivity Apparatus
Get Price Quote
We are offering This heat flow meter is a commercial apparatus for thermal conductivity (or thermal resistance) of insulation materials by guarded hot-plate. Specification GUARDED HOT PLATE :- Size : Metering area :- 150 x 150 mm Guard : 75 mm all around with a gap of 3mm between guard and central. Overall size : 310 mm Plate thickness : 4 mm (approx). Material : brass Max. Working temperature: 150°C No. of thermocouples : 2 each in central & Guard plate. (One for control & 3 for monitoring) Central plate: 4 thermocouples are mounted on Central Plate (two at upper and lower side at the center) i.e. total 4 thermocouples. Guard plate: 4 thermocouples are mounted on Central Plate (two at upper and lower side at the center) i.e. total 4 thermocouples. COLD PLATES :- Overall Size : 310 x 310 mm Thickness : 1 mm (approx) Material : copper. No. of thermocouples : 4 in plate.(One for control & another for monitoring) Maximum working temperature : -20°C. Specimen dimensions A single specimen is required. Thickness: 30 mm to 75 mm(The thickness is within 2% of its mean thickness over its whole area) Note: Thinner specimens can be measured, if it is the thickness that they will be supplied to the end user Length and breadth: 310*310 mm (Within range 305 mm to 311 mm) Flatness: The 310 mm square faces are flat to better than 0.2 mm (Flatness criteria do not apply to compressible or fibrous insulations) Thermal conductivity range: up to 0.5 Wm·K Mean specimen temperature range: -20 to 150 c Confirms as per IS:3346
ion exchange
Get Price Quote
There are two basic types of resin cation-exchange and anion-exchange resins. Cation exchange resins will release Hydrogen (H+) ions or other positively charged ions in exchange for impurity cations present in the water. Anion exchange resins will release hydroxyl (OH-) ions or other negatively charged ions in exchange for impurity anions present in the water.
Digital Capacitance Meter
Get Price Quote
Digital Capacitance Meter, Toxicity Tester, HTC LCR-4070 Digital LCR Meter
Energy Monitoring System
Get Price Quote
Energy Monitoring System, industrial control panel, Plc System
Energy Meters
Get Price Quote
Energy Meters
conductivity sensors
Get Price Quote
conductivity sensors, Planer Machine, Festo Rodless Cylinders