Clean Agent Fire Extinguishers
BOC NAF PIV based extinguishing agent capable of fighting class A , B & C High performance extinguishing agent High quality epoxy paint Clean agent electrically non conductive, low in toxicity Clean agent extinguisher manufactured out of CRCA sheet in all welded construction Controlled discharge Brass forged head valve with simple squeeze operation Unique gauge testing systems Environmental friendly, very low ozone depletion potential Rechargeable & easy to service
foam tank
Type : Vertical
Color : Red
Condition : New
Capacity : 500 to 10000 Ltrs
Material : Metal
Shape : Round
Fire Hydrant and Sprinkler System
The fire hydrant system is the backbone of the fire fighting system in a building or premises. The system is a water distribution system consisting of water tank, suction piping, fire pumps and a distributed piping system. The distributed piping system establishes connectivity throughout the building through fire hydrants, hoses and nozzles. The purpose of the fire hydrant system is to provide a readily available source of water to any point throughout the building. This helps in controlling fire during an emergency. Through the fire main system, the fire-fighter is provided with a reliable and versatile system capable of providing a number of different methods for controlling the fire, water can be supplied through the fire hydrant system as a straight stream for combating deep seated fires and as a spray for combating combustible liquid fires. Sprinkler System A fire sprinkler system is the most effective fire prevention system since it extinguishers fire before it gets too big. A fire can create havoc in a few minutes. This can be avoided by installing the fire sprinkler system. The fire sprinkler system is activated when heat in the room rises to a threshold-level. A fire sprinkler system douses the fire by sprinkling water on it, effectively smothering it before it spreads further.Most people who die as a result of fire don’t actually burn to death. Predominantly, they die of suffocation from smoke inhalation. Fire sprinkler system is the only fire protection device that cuts through the smoke, weighting down larger smoke particles before they have a chance to rise. This lessens smoke thickness, making it easier to breathe.Fire sprinkler systems are connected with water pipes on ceiling and walls. The network of water pipes is either filled with water at all times, or hooked up to the water main or a storage tank via a water pump or valve.The sprinkles themselves are installed on ceilings or sometimes high on the walls. Each sprinkler in the fire sprinkler system is fitted with a glass bulb containing gases and liquids that expand under heat, or a fusible link with seals that melt when they contact with high heat.When fire starts, it sends a plume of hot air toward the ceiling. This expands the contents of the glass bulb. When the gases get hot, the glass bulb breaks. In the case of the fusible link, the heat melts the seals on the links. This releases a valve connected to the water pipes in the ceiling, dousing the fire with water. The glass bulbs and link seals are often designed to break at a specific temperature usually around 68°C.The droplets released by the fire sprinkler system ate strictly controlled to be large enough to penetrate the core of the fire without evaporating. They bring the temperature inside the fire below sustainable levels. As a result, the fire goes out quickly before it spreads to different areas of the premises.
STAND ALONE BATTERY OPERATED SMOKE DETECTOR
* Unique Light Labyrinth with High Stability * Adopted CMOS with low power consumption* High Adaptability to the ambient, with Dust proof, moth proof, moisture proof, anti-white light, anti-electromagnetic interferences design * Sound & Flash Alarm, Low Voltage indication, Self-test * Function, network output operated* Manual test, Auto Reset Function* DC 9V Battery Operated* 60 square meter @ 4 meter height* 85dB/m standard level
Fire Extinguisher
1,500 Per Piece
Material : Mild Steel
Fire Class : A Class
Capacity : 2 Kg
Fire Extinguisher Type : Dry Powder Type
Body Material : Carbon Steel
Usage/Application : For Industrial Use
ABC Fire Extinguisher
4,000 Per Piece
Fire Rating : 34A 183B 183C
Discharge Range : 4 meter
Discharge Time : 15 second
Working Pressure : 14 bar at 20 degree C
Warranty : 5 Years
Capacity : 6 kg
Weight : 9.30 kg
Temperature Range : -30 degree C to 60 degree C
Height : 540mm
Dimensions : 154 x 245 x 540 mm
Extinguisher Agent : ABC Dry Powder
Cylinder Diameter : 154mm
Fire Extinguishers
Fire extinguishers.
photoelectric detectors
Sprinkler Irrigation System
Sprinkler irrigation is a method of applying irrigation water which is similar to natural rainfall. Water is distributed through a system of pipes by pumping at pressure above 2 kgcm2 and then sprayed into the air through sprinklers so that it breaks up into small water drops which fall to the ground.
CO2 Fire Extinguisher
Sprinkler Irrigation System
fire extinguisher equipment
Foam Equipments
eo gas cartridge
Fire Extinguisher
Fire Fighting Equipment
Fire Fighting Equipment