Fire Sprinkler Systems Dealers in Ahmedabad

(6 products available)
  • Fire Sprinkler System

    Fire Sprinkler System

    90 Per Piece

    • Style: Pendent
    • Finishing: chrome pleted
    • Material: brass
    • Usage: sprinkler systems
    • Pressure: Medium
    more..
  • Fire Sprinkler System

    Fire Sprinkler System

    Get Price Quote

    In smaller workplaces, portable fire extinguishers will probably be sufficient to tackle small fires. However, in more complex buildings, or where it is necessary to protect the means of escape and/orthe property or contents of the building, it may be necessary to consider a sprinkler system. Sprinkler systems are traditionally acknowledged as an efficient means of protecting buildings against extensive damage from fire. They are also now acknowledged as an effective means of reducing the risk to life from fire. Systems are being developed which may be suitable for use in workplaces with residential areas, such as care homes and houses in multiple occupancy. Sprinkler systems need to be specifically designed and installed to the appropriate hazard category in accordance with an approved code of practice. We offer Design & Engineering of an integrated Sprinkler System with fine protection engineering standards Network of specially sized or hydraulically designed piping installed in building, structure generally overhead with attached sprinkler in a systematic pattern proper location of alarm valve and orientation as per our best design practice makes us leader in designing this system. We design sprinkler system as per TAC, NBC, Indian and NFPA Standards or guidelines. We design Sprinkler System as per TAC, NBC, Indian and NFPA Standards or guidelines.

    more..
  • Best Deals from Fire Sprinkler Systems

  • Fire Hydrant and Sprinkler System

    Fire Hydrant and Sprinkler System

    Get Price Quote

    The fire hydrant system is the backbone of the fire fighting system in a building or premises. The system is a water distribution system consisting of water tank, suction piping, fire pumps and a distributed piping system. The distributed piping system establishes connectivity throughout the building through fire hydrants, hoses and nozzles. The purpose of the fire hydrant system is to provide a readily available source of water to any point throughout the building. This helps in controlling fire during an emergency. Through the fire main system, the fire-fighter is provided with a reliable and versatile system capable of providing a number of different methods for controlling the fire, water can be supplied through the fire hydrant system as a straight stream for combating deep seated fires and as a spray for combating combustible liquid fires.  Sprinkler System A fire sprinkler system is the most effective fire prevention system since it extinguishers fire before it gets too big. A fire can create havoc in a few minutes. This can be avoided by installing the fire sprinkler system. The fire sprinkler system is activated when heat in the room rises to a threshold-level. A fire sprinkler system douses the fire by sprinkling water on it, effectively smothering it before it spreads further.Most people who die as a result of fire don’t actually burn to death. Predominantly, they die of suffocation from smoke inhalation. Fire sprinkler system is the only fire protection device that cuts through the smoke, weighting down larger smoke particles before they have a chance to rise. This lessens smoke thickness, making it easier to breathe.Fire sprinkler systems are connected with water pipes on ceiling and walls. The network of water pipes is either filled with water at all times, or hooked up to the water main or a storage tank via a water pump or valve.The sprinkles themselves are installed on ceilings or sometimes high on the walls. Each sprinkler in the fire sprinkler system is fitted with a glass bulb containing gases and liquids that expand under heat, or a fusible link with seals that melt when they contact with high heat.When fire starts, it sends a plume of hot air toward the ceiling. This expands the contents of the glass bulb. When the gases get hot, the glass bulb breaks. In the case of the fusible link, the heat melts the seals on the links. This releases a valve connected to the water pipes in the ceiling, dousing the fire with water. The glass bulbs and link seals are often designed to break at a specific temperature usually around 68°C.The droplets released by the fire sprinkler system ate strictly controlled to be large enough to penetrate the core of the fire without evaporating. They bring the temperature inside the fire below sustainable levels. As a result, the fire goes out quickly before it spreads to different areas of the premises.

    more..
  • Fire Fighting Sprinklers

    Get Price Quote

    Fire Fighting Sprinklers, fire sensor, fire control devices, fire glove

    more..
  • fire sprinkler systems

    Get Price Quote

    fire sprinkler systems, Fire Alarm System, Fire Extinguishing Systems

    more..
  • Fire Sprinkler System

    Get Price Quote

    Fire Sprinkler System, Fire Pump Panel

    more..
Filter by Locality
top