Transformer Testing Services, Transformer Repairing Services
Get Price Quote
We introduce ourselves as a transformer overhauling and servicing provider. Representing crompton greaves in western india providing servicing for cg transformers and switchgears. We can facilitate commissioning work for all the transformers in india. Also we are providing training of all substation equipments. residual life assessment (rla) of power transformer description of condition monitoring test of power transformer:- 1. capacitance and tan delta test of bushing & winding, 2. frequency response analysis, 3. winding resistance test, 4. turns ratio test, 5. magnetic balance test, 6. excitation current, 7. ir & pi value measurement test, 8. oil test as per is: 1866, 9. dga (oil test), 10. furan (oil test), 11. domino oil test, 12. Core insulation test, we would feel fortunate if given a chance to serve to your organization. Also refer our site: www.aktranscharger.com contact: info at aktranscharger dot com
transformers repairing service
Get Price Quote
transformers repairing service, stabilizer repairing service
Looking for Industrial Appliances Repair service Providers
Distribution Boards
Get Price Quote
We are offering distribution boards advanced communication technology that inspires.. modular circuit breakers - xc60 !"breaking capacity as per iec 60898 and isiec 60898, icn = 10ka !"breaking capacity as per iec 60947-2, icn = 15ka, upto 40a !"higher installation life : energy limitation class: 3 !"tropicalization: t2 - relative humidity 95% at 55oc !"higher performance by low cost : cascading* !"increase system continuty : discrimination* !"reference temperature of 50oc as per iec60947-2# modular circuit breakers - c120 !"breaking capacity as per iec 60898, icn = 10ka15ka !"positive break indication !"degree of pollution: 3 (suitable for industrial environment) !"operating temperature: -30 to 700c !"terminal connections: # flexible cables up to 35 sq. Mm # rigid cables up to 50 sq. Mm reference temperature 500c as per iec 60947-2 residual current circuit breakers (rccbs) - xid complies to standards iecen 61008-1 and is 12640 ac class selective range available for time based discrimination immune to nuisance tripping due to transient over voltage (lighting, switching surges) easy monitoring: earth fault indication on front face mandatory to use of-s auxiliary to add any indication or tripping auxiliary modular distribution degree of protection: ip43 for double door and ip30 for single door detachable chassis gives ease and comfort in internal wiring cement spill protector (csp) ensures no dust or cement particles will enter dbs optimized dimensions providing enough wiring space stoppers on din rail dbs are provided with complete wire set, insulated busbars, labels, cable ties, blanking plates and csp (wire sets and busbars not provided in tier db’s) enclosures, distribution boards and p&s units have the provision for mounting modular devices as shown in the photograph. ppi distribution board (tpn ) - horizontal format.
air compressor repair
Get Price Quote
air compressor repair
Transformer Repairing Service
Get Price Quote
Transformer Repairing Service, Stabilizer, Transformers, Ups