Horizontal Cylindrical Autoclave
Get Price Quote
We are engaged in manufacturing, supplying and exporting a wide range of Medical Sterilizer. These products are designed in various specifications to meet the diversified needs of the clients. Our quality controllers make sure that the range is stringently tested on various parameters before it gets delivered to the clients. We offer:Ideal for parenteral solutions, injectables, mattresses and hospital dressings, High Pressure Cylindrical Autoclave Sterilizer is offered at industry leading price rates. The range has an operating temperature 121° C or higher. Provided with safety precautions such as pressure locking door, spring loaded safety valve and dead weight safety valve.
Vertical Double Drum Autoclave
Get Price Quote
Best Deals from Industrial Autoclave
Horizontal Cylindrical Autoclave sterilizer
150,000 Per Piece
Industrial Autoclaves
Get Price Quote
Dry Heat Sterilizer
Get Price Quote
SALIENT FEATURES : Ambica Boiler & Fab. depyrogenation steriliser are capable of performing up to 280 ° C, during the entire cycle. We have achieved this, due to our unique chamber construction and filter suspension system, and our never ending work for further improvements. High Temperature Hepa Filters High Temp HEPA filters are installed at inlet and exhaust side of the DHS. The HEPA-filters inside the chamber are equipped with full depth and height of chamber for suspension system solving the particle problem during heating and cooling. Chamber The Ambica Boiler & Fab. depyrogenation steriliser is made of stainless steel 316L. The chamber is fully welded inside, no leakage to the insulation can occur and the chamber is very easy to clean. The water cooling element is a continuous welded unit without any connections inside the cabinet boundary. It is pressure tested and is expected to last the lifetime of the steriliser. Door gasket As standard, Neelam Industries sterilizers are equipped with double door gaskets (FDA-approved). The purpose of double door gasket is to render maximum security, allowing no leakage between the chamber and the outside. Further more the double gasket minimizes the surface temperature of the sterilizer, and any undesired air flow in the sterile area. Superior air control - Guarantee for complete sterilizationNeelam Industries depyrogenation sterilisers operate in accordance with the forced convection principle with fast air circulation securing a rapid heat transmission to the load. Together with the shape and position of the electrical heating element, the calculated air distribution plates ensure a unique temperature distribution in the sterilization chamber. The temperature distribution is tested and fixed before delivery and does not require any adjustments in the life time of the steriliser, accordingly no down time for re-validation is needed. The uniform temperature in the chamber make it possible to fix the set-point temperature very close to the required minimum temperature for the sterilization. Program Cycle The cycle of a ABF sterilizer is fully automatic. Drying The cycle starts with the drying phase where the damper on the exhaust is open ensuring, that any moisture will be removed from the chamber. Heating At a set-point temperature decided by the customer, the damper will close and the temperature will rise to the sterilizing set-point temperature. The damper will also stay closed during sterilization. Ambica Boiler & Fab. Sterlisers are equipped with a power-ful heating element to shorten the heating time Sterilizing The sterilizing timer can be started by the load sensors. The sterilizing timer will only be running if all the load sensors are within an acceptable range from the sterilizing set-point. Cooling If the cycle time is important, forced air cooling or water cooling is available for rapid cooling in customized model.
Depyrogenation Tunnels
Get Price Quote
The Sterilization Depyrogenation cycle is based on selection of cycle times and exposure of temperature that will sterilize or depyrogenate the glassware to an acceptable low probability level of contamination, without adversely affecting the critical parameters of the product. Generally Heat destroys micro organisms. The destruction process of microorganisms is a function of time and temperature. The rate of destruction is linear logarithmic, means in a given time interval and at a given temperature, the same percentage of the bacterial population will be destroyed. Hence forth introduce “Forced Conventional Dry Heat Sterilizer” (Sterilizing Tunnel).
Vertical Autoclave
Get Price Quote
Pharmaceutical Sterilizing Tunnel
1,000,000 Per
Vertical Autoclave
38,000 Per Piece
1 Piece (MOQ)
Cement Autoclave
Get Price Quote
It consists of a stainless steel cylinder with an insulated cover, mounted on a sturdy supporting frame, enclosed in a heat insulated metal housing, attractively finished. The attached control unit encloses a sensitive pressure regulator and pressure gauge, power switches and pilot lamps for controlling the electric heating units. Inside Chamber dimensions: 15 cm dia x 60 cm height, with stainless steel Cylinder (20 kg/cm2pressure capacity) Suitable for operation on 220 V, 50 Hz, Single Phase, AC Supply. Supplied complete with Test Bar Holder, Special Rack to hold specimens above water level in the autoclave and in a vertical position to expose them in the same manner.
Dry Heat Sterilizer
Get Price Quote
Salient Features Complete GMP model. Basic structure made from M.S. Heavy angles. Sterilizer inner walls made from AISI SS 316 and outer walls made from AISI SS 304. Doors provided on both sides, one opening is in non-sterile area and second opening in sterile area. A’ grade mineral wool insulation to optimize heat effectiveness and stop heat loses. Dynamically balanced fan provided for hot air circulation to achieve uniform temperature. Complete electric panel board with pulley and damper connection. Process Operation The Ampoules / Vials placed in trays are washed in non-sterile room and loaded on the trolley. The trolley is moved to the sterilizer on a transfer trolley. Temperature and Times are set on the Digital Controller. The Impeller mounted on the top circulates the hot air horizontally over the charge. The air is heated by elements mounted on the top. Fresh air enters the system through Hepa Filter Module. The system incorporates two doors, one opening into the sterile room and the other opening in the non-sterile room. Both the doors are pneumatically interlocked. The temperature profile during sterilization cycle is recorded on a circular chart recorder, validation of the system is provided by a six-point digital temperature scanner. After the time period required for sterilizing the batch has elapsed, the heating circuit shuts of the pneumatics damper (exhaust) opens and cooling operation commences.
Horizontal Autoclave
Get Price Quote
Contsrtuction The unit has outer chamber, inner chamber, Boiler, Lid and Jacket - all made of AISI 304 grade stainless steel. For controlling sterilization cycle, a three way valve or a multiport valve - made of S.S. is provided. The unit have a very efficient ms radial locking arrangement, fitted on ms ring, duly chrome plated. It is supplied complete with vaccum breaker, water level indicator, steam trap and automatic pressure control switch. The whole unit is mounted on a robust tubular ms stand. Operatable on single / three phase, 220/440 volts, 50Hz A.C. Supply. Mode of Heating Electrically heated by special flange type / immersion type heaters bearing ISI mark, to work on single / three phase, 220/240 volts, 50Hz, A.C. supply. Working Pressure The pressure inside the chamber is variable from 5 psi to 20 psi. But the normal recommended pressure for sterilization process is 1.2 Kgf/cm2 (15 psi). Working Temperature : 121 deg.CWorking Pressure : 1.26 Kgf/cm2 (15 psi)Hydro Test Pressure : 2.5 Kgf/cm2 (35 psi) Working Chamber Size Volume Load (KW) 400 x 600 mm 78 Ltrs 6 KW 500 x 900 mm 135 Ltrs 10 KW 550 x 750 mm 152 Ltrs 9 KW 400 x 1100mm 162 Ltrs 12 KW 500 x 1200mm 185 Ltrs 12 KW 600 x 1200mm 300 Ltrs 18 KW 750 x 1200mm 525 Ltrs 18 KW Optional Accessories Semi Automatic Pressure Control Switch. Automatic Low Water Cut Off Device Mechanical Timer (0-60 Min) Mechanical Timer With Alarm System Solid State Digital Timer (0-120 Mins) Solid State Digital Temperature Indicator. Micro-Processor Based Programmable Timer Controller. Micro-Processor Based Programmable Timer (0-120) Circular Temperature Chart Recorder (24 Hours/Seven Days) Strip Chart Recorder Digital Pressure Transducer Cum Indicator Automatic Pressure And Temperature Mapping System With Validation Soft Ware (Without Pc) Rubber Gaskets Neoprene rubbler or silicon rubber Size 250 X 450 MM 300 X 500 MM 350 X 550 MM 450 X 600 MM 500 x 1200mm 550 X 750 MM Spare Heaters (In-house custom Developed SS Heaters) 2 KW 3 KW 4 KW
Cylindrical Horizontal Autoclave
Get Price Quote
Cylindrical Horizontal Autoclave, ethylene oxide cartridges, Eto Sterilizer
Vertical Autoclave
Get Price Quote
Vertical Autoclave is an asset to Hospitals, Pharmaceutical, Biotechnology, Tissue culture, Bio-Fertilizer Laboratories and Research Institutes, Micro-biology lab.
Cement Autoclave
Get Price Quote
cement colours, cement mortar, coromandel cement
Dry Heat Sterilizer
Get Price Quote
Dry Heat Sterilizer, glass vial, Rubber Closure, Rubber Stopper