Dry Heat Sterilizer
Get Price Quote
Salient Features Complete GMP model. Basic structure made from M.S. Heavy angles. Sterilizer inner walls made from AISI SS 316 and outer walls made from AISI SS 304. Doors provided on both sides, one opening is in non-sterile area and second opening in sterile area. A’ grade mineral wool insulation to optimize heat effectiveness and stop heat loses. Dynamically balanced fan provided for hot air circulation to achieve uniform temperature. Complete electric panel board with pulley and damper connection. Process Operation The Ampoules / Vials placed in trays are washed in non-sterile room and loaded on the trolley. The trolley is moved to the sterilizer on a transfer trolley. Temperature and Times are set on the Digital Controller. The Impeller mounted on the top circulates the hot air horizontally over the charge. The air is heated by elements mounted on the top. Fresh air enters the system through Hepa Filter Module. The system incorporates two doors, one opening into the sterile room and the other opening in the non-sterile room. Both the doors are pneumatically interlocked. The temperature profile during sterilization cycle is recorded on a circular chart recorder, validation of the system is provided by a six-point digital temperature scanner. After the time period required for sterilizing the batch has elapsed, the heating circuit shuts of the pneumatics damper (exhaust) opens and cooling operation commences.
Stainless Steel Vertical Autoclave
35,000 Per Piece
1 Piece (MOQ)
Best Deals from Industrial Autoclave
Vertical Autoclave
42,000 Per Piece
1 Piece (MOQ)
Vertical Autoclave
38,000 Per Piece
1 Piece (MOQ)
Vertical Autoclave
Get Price Quote
Vertical Autoclave
70,000 - 190,000 Per piece
10 Piece (MOQ)
Depyrogenation Tunnels
Get Price Quote
The Sterilization Depyrogenation cycle is based on selection of cycle times and exposure of temperature that will sterilize or depyrogenate the glassware to an acceptable low probability level of contamination, without adversely affecting the critical parameters of the product. Generally Heat destroys micro organisms. The destruction process of microorganisms is a function of time and temperature. The rate of destruction is linear logarithmic, means in a given time interval and at a given temperature, the same percentage of the bacterial population will be destroyed. Hence forth introduce “Forced Conventional Dry Heat Sterilizer” (Sterilizing Tunnel).
Cement Autoclave
55,000 Per Piece
Silent Features: Rust proof stainless steel pressure vessel Specially designed Steam Safety Valve, pressure control switch and Temp. control switch – Triple Safety precautions for operator safety Accurately Calibrated Pressure Gauge Guaranteed timings and performance as per IS 4031 General Descripation & Specifications:The Autoclave is double walled. Inner boiler chamber of stainless steel cylinder, with concealed yet easily replaceable heaters surrounding the vessel for quick heating. The boiler lid is of thick stainless steel and can be bolted to the chamber by heavy hexagonal nuts. The silicon gasket, seated in a groove, makes the unit leak proof even at high pressure. The boiler is mounted in between the strong angle iron frame and covered with CRC sheet – attractively powder coated. The outer cover can also be of Stainless steel at an extra cost. The gap in between the walls is filled with thermal insulation to prevent heat loss and energy. The control system consist of sensitive pressure regulator, pressure gauge, safety valve, temperature control switch, power ON-OFF switch and pilot lights to indicate status of the electric heating units and control switches. Standard Accessories: Special rack to hold specimens above water level in the autoclave and in vertical position Pressure gauge with calibration report with national traceability Silicon rubber Gasket Spanner Accessories At Extra Cost: Length comparator with dial micrometer 0.002mm X 5mm shrinkage bar moulds(single/two/triple gang) PID Auto tuning Digital Temp. indicator cum controller with or without PC interface for data logging PID Auto tuning Digital Pressure indicator cum controller with or without PC interface for data logging Spare heater set Spare Silicon Gasket Spare Pressure gauge Spare safety valve
Pharmaceutical Sterilizing Tunnel
1,000,000 Per
Vertical Autoclave
Get Price Quote
Horizontal Rectangular Autoclave
Get Price Quote
We are engaged in manufacturing, supplying and exporting a wide range of Medical Sterilizer. These products are designed in various specifications to meet the diversified needs of the clients. Our quality controllers make sure that the range is stringently tested on various parameters before it gets delivered to the clients. We offer:Provided with safety precautions such as pressure locking door, spring loaded safety valve and dead weight safety valve, All necessary safety precautions namely, pressure locking door, spring loaded safety valve, dead weight safety valve etc incorporated.
Rectangular Autoclave
Get Price Quote
We are engaged in manufacturing, supplying and exporting a wide range of Medical Sterilizer. These products are designed in various specifications to meet the diversified needs of the clients. Our quality controllers make sure that the range is stringently tested on various parameters before it gets delivered to the clients. We offer:
Vertical Double Drum Autoclave
Get Price Quote
Sterilizing and Depyrogenation Tunnel
Get Price Quote
The Sterilizing and Depyrogenation Tunnel is a machine used in various industries for the sterilization and depyrogenation of glass vials and ampoules. The Sterilizing tunnel is also known as the depyrogenating tunnel and it uses hot air for the sterilization of ampoules and vials. Sterilizing tunnel for vials is designed as a fully automatic system which uses dry heat with the forced convection of filtered air for depyrogenation of glass vials. The sterilizing tunnel for ampoules is equipped with a high efficiency particulate air filter to achieve sterilization of ampoules. Online sterilization tunnel is also known as the pharmaceutical sterilizing tunnel due to its wide use in the Pharmaceutical industry. The machine is provided with a 21CFR compliant data management system. Process of Operation The vials or ampoules are packed on a stainless steel belt which moves them through the preheating, heating and cooling zones. In every zone the ampoules are treated with HEPA filtered air to make them ready for filling. The differential pressures are controlled and monitored by the machine for proper operation of the tunnel. The sterilization and depyrogenation is based on the selection of cycle times and exposure to temperature. The entire process is automated and monitored by a touch screen display for easy operation and control access. Salient features: Automatic sterilization of the cooling zone Easy Introduction of validation thermocouples through ports Equipped with Ampoule flow control logic Monitoring of conveyor belt with alarms Filter modules are equipped with differential pressure gauges for pressure monitoring Balancing of air between aseptic and non-aseptic areas Optional positioning, adjustment and monitoring of Shutter Touch screen display screen for easy access and control Diagnostic screen highlight alarm for production control
Cement Autoclave
Get Price Quote
We are the main supplier of this product.
Vertical Autoclave
Get Price Quote
Introduction: Our vertical autoclaves are widely used for the day to day sterilization procedures and in various laboratory applications.We specialize in both standard and customized models, specifically designed to meet the challenging demands of various scientists for individual and specialized research applications. Apart from that, we are also supplying our economical autoclave in India catering to variety of customers ranging from Defense Installations, Research Laboratories and Educational Institutes and various R&D laboratories of leading national and multinational companies.
Rectangular Autoclave
Get Price Quote
Mechanical removal of air initially from within the chamber with the use of a vacuum system ensures that no air-pockets hinder the steam penetration and hence the sterilization process. Steam Sterilizer for sterilization of varied Hospital equipment like gloves, linen, gauze, cotton, instruments, glassware etc. using standard 121°C & 134°C cycles which are pre-programmed in the memory of the PLC Microprocessor Electrical Steam-generator provided for all models up to a chamber volume of 1000 liters. Temperature uniformly and accurately maintained throughout the chamber to within ± 0.5°C of the Set Sterilization temperature. Air Filter: 0.01 micron clean air-filter for stabilization of the internal air-pressure from vacuum conditioChamber Width (mm) n. Door safety: Door is automatically locked when chamber is under pressure. For double door models, both doors will not open simultaneously to ensure sterile chain integrity.
Cement Autoclave
Get Price Quote
Cement Autoclave
Get Price Quote
It consists of a stainless steel cylinder with an insulated cover, mounted on a sturdy supporting frame, enclosed in a heat insulated metal housing, attractively finished. The attached control unit encloses a sensitive pressure regulator and pressure gauge, power switches and pilot lamps for controlling the electric heating units. Inside Chamber dimensions: 15 cm dia x 60 cm height, with stainless steel Cylinder (20 kg/cm2pressure capacity) Suitable for operation on 220 V, 50 Hz, Single Phase, AC Supply. Supplied complete with Test Bar Holder, Special Rack to hold specimens above water level in the autoclave and in a vertical position to expose them in the same manner.
Industrial Autoclaves
Get Price Quote