Vertical Autoclave
Get Price Quote
Horizontal Autoclave
Get Price Quote
Best Deals from Industrial Autoclave
Horizontal Autoclave
Get Price Quote
Contsrtuction The unit has outer chamber, inner chamber, Boiler, Lid and Jacket - all made of AISI 304 grade stainless steel. For controlling sterilization cycle, a three way valve or a multiport valve - made of S.S. is provided. The unit have a very efficient ms radial locking arrangement, fitted on ms ring, duly chrome plated. It is supplied complete with vaccum breaker, water level indicator, steam trap and automatic pressure control switch. The whole unit is mounted on a robust tubular ms stand. Operatable on single / three phase, 220/440 volts, 50Hz A.C. Supply. Mode of Heating Electrically heated by special flange type / immersion type heaters bearing ISI mark, to work on single / three phase, 220/240 volts, 50Hz, A.C. supply. Working Pressure The pressure inside the chamber is variable from 5 psi to 20 psi. But the normal recommended pressure for sterilization process is 1.2 Kgf/cm2 (15 psi). Working Temperature : 121 deg.CWorking Pressure : 1.26 Kgf/cm2 (15 psi)Hydro Test Pressure : 2.5 Kgf/cm2 (35 psi) Working Chamber Size Volume Load (KW) 400 x 600 mm 78 Ltrs 6 KW 500 x 900 mm 135 Ltrs 10 KW 550 x 750 mm 152 Ltrs 9 KW 400 x 1100mm 162 Ltrs 12 KW 500 x 1200mm 185 Ltrs 12 KW 600 x 1200mm 300 Ltrs 18 KW 750 x 1200mm 525 Ltrs 18 KW Optional Accessories Semi Automatic Pressure Control Switch. Automatic Low Water Cut Off Device Mechanical Timer (0-60 Min) Mechanical Timer With Alarm System Solid State Digital Timer (0-120 Mins) Solid State Digital Temperature Indicator. Micro-Processor Based Programmable Timer Controller. Micro-Processor Based Programmable Timer (0-120) Circular Temperature Chart Recorder (24 Hours/Seven Days) Strip Chart Recorder Digital Pressure Transducer Cum Indicator Automatic Pressure And Temperature Mapping System With Validation Soft Ware (Without Pc) Rubber Gaskets Neoprene rubbler or silicon rubber Size 250 X 450 MM 300 X 500 MM 350 X 550 MM 450 X 600 MM 500 x 1200mm 550 X 750 MM Spare Heaters (In-house custom Developed SS Heaters) 2 KW 3 KW 4 KW
Horizontal Autoclave
300,000 Per piece
1 piece (MOQ)
Depyrogenation Tunnels
Get Price Quote
The Sterilization Depyrogenation cycle is based on selection of cycle times and exposure of temperature that will sterilize or depyrogenate the glassware to an acceptable low probability level of contamination, without adversely affecting the critical parameters of the product. Generally Heat destroys micro organisms. The destruction process of microorganisms is a function of time and temperature. The rate of destruction is linear logarithmic, means in a given time interval and at a given temperature, the same percentage of the bacterial population will be destroyed. Hence forth introduce “Forced Conventional Dry Heat Sterilizer” (Sterilizing Tunnel).
Vertical Autoclave
38,000 Per Piece
1 Piece (MOQ)
Cement Autoclave
55,000 Per Piece
Silent Features: Rust proof stainless steel pressure vessel Specially designed Steam Safety Valve, pressure control switch and Temp. control switch – Triple Safety precautions for operator safety Accurately Calibrated Pressure Gauge Guaranteed timings and performance as per IS 4031 General Descripation & Specifications:The Autoclave is double walled. Inner boiler chamber of stainless steel cylinder, with concealed yet easily replaceable heaters surrounding the vessel for quick heating. The boiler lid is of thick stainless steel and can be bolted to the chamber by heavy hexagonal nuts. The silicon gasket, seated in a groove, makes the unit leak proof even at high pressure. The boiler is mounted in between the strong angle iron frame and covered with CRC sheet – attractively powder coated. The outer cover can also be of Stainless steel at an extra cost. The gap in between the walls is filled with thermal insulation to prevent heat loss and energy. The control system consist of sensitive pressure regulator, pressure gauge, safety valve, temperature control switch, power ON-OFF switch and pilot lights to indicate status of the electric heating units and control switches. Standard Accessories: Special rack to hold specimens above water level in the autoclave and in vertical position Pressure gauge with calibration report with national traceability Silicon rubber Gasket Spanner Accessories At Extra Cost: Length comparator with dial micrometer 0.002mm X 5mm shrinkage bar moulds(single/two/triple gang) PID Auto tuning Digital Temp. indicator cum controller with or without PC interface for data logging PID Auto tuning Digital Pressure indicator cum controller with or without PC interface for data logging Spare heater set Spare Silicon Gasket Spare Pressure gauge Spare safety valve
Vertical Autoclave
Get Price Quote
Pharmaceutical Sterilizing Tunnel
1,000,000 Per
Cement Autoclave
Get Price Quote
It consists of a stainless steel cylinder with an insulated cover, mounted on a sturdy supporting frame, enclosed in a heat insulated metal housing, attractively finished. The attached control unit encloses a sensitive pressure regulator and pressure gauge, power switches and pilot lamps for controlling the electric heating units. Inside Chamber dimensions: 15 cm dia x 60 cm height, with stainless steel Cylinder (20 kg/cm2pressure capacity) Suitable for operation on 220 V, 50 Hz, Single Phase, AC Supply. Supplied complete with Test Bar Holder, Special Rack to hold specimens above water level in the autoclave and in a vertical position to expose them in the same manner.
Dry Heat Sterilizer
Get Price Quote
SALIENT FEATURES : Ambica Boiler & Fab. depyrogenation steriliser are capable of performing up to 280 ° C, during the entire cycle. We have achieved this, due to our unique chamber construction and filter suspension system, and our never ending work for further improvements. High Temperature Hepa Filters High Temp HEPA filters are installed at inlet and exhaust side of the DHS. The HEPA-filters inside the chamber are equipped with full depth and height of chamber for suspension system solving the particle problem during heating and cooling. Chamber The Ambica Boiler & Fab. depyrogenation steriliser is made of stainless steel 316L. The chamber is fully welded inside, no leakage to the insulation can occur and the chamber is very easy to clean. The water cooling element is a continuous welded unit without any connections inside the cabinet boundary. It is pressure tested and is expected to last the lifetime of the steriliser. Door gasket As standard, Neelam Industries sterilizers are equipped with double door gaskets (FDA-approved). The purpose of double door gasket is to render maximum security, allowing no leakage between the chamber and the outside. Further more the double gasket minimizes the surface temperature of the sterilizer, and any undesired air flow in the sterile area. Superior air control - Guarantee for complete sterilizationNeelam Industries depyrogenation sterilisers operate in accordance with the forced convection principle with fast air circulation securing a rapid heat transmission to the load. Together with the shape and position of the electrical heating element, the calculated air distribution plates ensure a unique temperature distribution in the sterilization chamber. The temperature distribution is tested and fixed before delivery and does not require any adjustments in the life time of the steriliser, accordingly no down time for re-validation is needed. The uniform temperature in the chamber make it possible to fix the set-point temperature very close to the required minimum temperature for the sterilization. Program Cycle The cycle of a ABF sterilizer is fully automatic. Drying The cycle starts with the drying phase where the damper on the exhaust is open ensuring, that any moisture will be removed from the chamber. Heating At a set-point temperature decided by the customer, the damper will close and the temperature will rise to the sterilizing set-point temperature. The damper will also stay closed during sterilization. Ambica Boiler & Fab. Sterlisers are equipped with a power-ful heating element to shorten the heating time Sterilizing The sterilizing timer can be started by the load sensors. The sterilizing timer will only be running if all the load sensors are within an acceptable range from the sterilizing set-point. Cooling If the cycle time is important, forced air cooling or water cooling is available for rapid cooling in customized model.
Rectangular Autoclave
Get Price Quote
Mechanical removal of air initially from within the chamber with the use of a vacuum system ensures that no air-pockets hinder the steam penetration and hence the sterilization process. Steam Sterilizer for sterilization of varied Hospital equipment like gloves, linen, gauze, cotton, instruments, glassware etc. using standard 121°C & 134°C cycles which are pre-programmed in the memory of the PLC Microprocessor Electrical Steam-generator provided for all models up to a chamber volume of 1000 liters. Temperature uniformly and accurately maintained throughout the chamber to within ± 0.5°C of the Set Sterilization temperature. Air Filter: 0.01 micron clean air-filter for stabilization of the internal air-pressure from vacuum conditioChamber Width (mm) n. Door safety: Door is automatically locked when chamber is under pressure. For double door models, both doors will not open simultaneously to ensure sterile chain integrity.
Pharmaceutical Sterilizing Tunnel
2,200,000 Per Piece
Horizontal Cylindrical Autoclave sterilizer
150,000 Per Piece
Horizontal Cylindrical Autoclave
Get Price Quote
We are engaged in manufacturing, supplying and exporting a wide range of Medical Sterilizer. These products are designed in various specifications to meet the diversified needs of the clients. Our quality controllers make sure that the range is stringently tested on various parameters before it gets delivered to the clients. We offer:Ideal for parenteral solutions, injectables, mattresses and hospital dressings, High Pressure Cylindrical Autoclave Sterilizer is offered at industry leading price rates. The range has an operating temperature 121° C or higher. Provided with safety precautions such as pressure locking door, spring loaded safety valve and dead weight safety valve.
Industrial Autoclaves
Get Price Quote
Sterilizing Tunnel for Ampoules & Vials
Get Price Quote
Harsiddh Engineering Company, being leading name in the manufacture and export of pharmaceutical packaging machinery provides excellent decontamination and sterilization equipments. Our specially designed equipment is used in sterilization and depyrogenation of ampoules, bottles and vials. The machine comes as a complete unit with in-feed system, preheating and sterilizing zone, cooling and exit feed mechanism. As the bottles and vials move along the conveyor, they are sterilized. The equipment receives materials from up line washer and these are directed to the drying zone. At this zone, hot air vaporizes the washing moisture and preheats the bottles. They then move to the hot zone where they undergo sterilization and depyrogenation through heating. They are then subjected to cold air which cools them off before entering aseptic region. Our machines have CE certification. Our sterilization machines uses advanced instrumentation and control topologies to effectively moderate heat, water, air and other materials. Temperature sensors regulate heating and cooling while pressure gauges regulate the system pressure. The conveyor belt speed is also carefully controlled. In addition the system has an advanced PLC control module that monitors and regulates all processes. Silent Features Repetitive accuracy in reduction of endotoxin count. High productivity due to reduced idle time and optimization of operating time. Infinitely variable speed to achieve optimum production. Swift and convenient to use machine. Intelligent logic control systems for controlling temperatures in heating and cooling zones. Complete closed loop systems for heating zone and cooling zone. Important parameters are password protected. Graphics for displaying and editing various procted. Accurate data logging on to printer and recording onto strip chart recorder (optional). Auto shut down after batch completion Automated Self Sterilization of the cooling zone using Dry Heat Documentation available for qualification, validation Full PLC controlled and reliable depyrogenation process Double wall asbestos free ceramic wool insulated re circulatory module containing high temperature EU – 13 grade final HEPA filter with suck back mechanism suitable for 300 °C continuous repeated cycle. This zone provides uniform hot air over the glassware for the Purpose of de pyrogenation. In this zone the temperature raises as quickly as Possible by the help of heating element, without inducing cracking due to excessive thermal stress. The glassware remains in this zone at a required time period to meet The specified endotoxins reduction generally > 3 log scale. This section consist of unidirectional hot air flow unit with turbine blower assembly, High temperature HEPA filter (up to 350 °C) and heater bank assembly. Integrated temperature sensors are provided for monitoring & controlling purpose of Temperature inside the sterilizing zone. For this purpose one sensor is placed above The HEPA filter and the sensor is placed at the entry side of sterilizing zone. For Extra precaution one temperature sensor provided at Heater Assembly ( 375 °C) is placed for protection of Heaters. The entry and exit side of the sterilizing zone consists of manually adjustable profile Plates resulting in maximum temperature uniformity and ensure consistent result for Glassware with varying sizes.
Horizontal Autoclave
Get Price Quote
Vertical Double Drum Autoclave
Get Price Quote
Vertical Autoclave
Get Price Quote
Vertical Autoclave is an asset to Hospitals, Pharmaceutical, Biotechnology, Tissue culture, Bio-Fertilizer Laboratories and Research Institutes, Micro-biology lab.
Dry Heat Sterilizer
Get Price Quote
Dry Heat Sterilizer, glass vial, Rubber Closure, Rubber Stopper
Horizontal High Pressure Autoclave
Get Price Quote
ethylene oxide cartridges, Eto Sterilizer, Rectangular Sterilizer