Linear Vial Washing Machine Dealers in Rakhial, Ahmedabad

(4 products available)
  • Linear Vial Washing Machine

    Linear Vial Washing Machine

    Get Price Quote

    • Capacity: 80 Ltrs. S.S. 316
    • Rate: 6000 Vials per hour
    • Specifications: 0.5 HP / 415 Volts
    • Dimensions: 2290 MM (L) X 1175 MM (W) X 1575 MM

    'Bhagwati High Speed Linear Vial Washing Machine is used for washing of Vials and finds wide application in Pharmaceuticals Industries. The automatic loading arrangement facilities loading of Vials on to SS wire mesh conveyor through feed conveyor or Vials are pushed manually from feed table. This saves manpower as Vials are feed into pockets automatically. The automatic unloading mechanism consists of unloading Vial continues on to turn table Vials will be pushed from in feed tray and then move on wire woven conveyor belt, which align the Vial in correct position, to enter in to the carrier pocket with help of oscillating guide rails. Oscillating arm deliver the Vial inside pocket in mouth down position over spraying nozzles. Multijet sprayers fixed at the top cause the total external and internal surface to be washed. To avoid any possible cross contamination between two different waters. Each washing station is provided with an independent circuit. Carrier pocket is moving with indexing motion. When the baskets have completed their motion the needles are lifted. They penetrate the Vials, spraying jets of water or compressed air then return down. The baskets movement then advances by one station. Each station of Vials passes through the washing cycles selected.

    more..
  • Automatic Linear Vial Washing Machine

    Automatic Linear Vial Washing Machine

    Get Price Quote

    Shree Bhagwati very critically reviewed vial washing operations in the parenteral section and found methods either very primitive or concepts with probabilities or too perfect and highly expensive. Considering above facts, a very imaginative vial washing machine Model SBVW-150 is devised to ensure simple & modular operation, where each individual vial is positively washed with maximum of seven washes. Operation: The Vial trays are directly un-loaded to the vial tray from which it is pushed on to the turn-table. The turn-table slowly and steadily feed vials to the two tracks feed worm, where vials are automatically inverted. The synchronized star-wheel places two vials, one by one to the two tracks indexing chain. The indexing chain positively carries inverted pair of vials through seven sequential washes. At the end of washing operations vials are reinvented back into original position and collected in the tray.   Salient Features Very compact, rigid, & modular construction. All contact parts with D.M. water and distilled water of S.S. 316 construction and argon arc welded. The unit built on S.S. square pipe frame and totally encompassed with S.S. coverings in pleasing matte finish to avoid corrosion and ease of cleaning even from inside. The washing section is totally covered with acrylic cabinet and collecting trays ensure total removal of water in the drain or recirculation tank Absolutely simple machine, with only six change parts, which can be changed within few minutes. All exposed parts are of S.S. 304 or hard chrome plated brass for corrosion free long life. The seven sets of nozzle enter into the vials mouth during the washing operation ensuring penetration of washing medias to the core A perfect washing principle. Fixed top nozzles at each washing station ensures external washing of vials at the same time of internal washing. The flow of washing medias stop during the indexing of chain, saving straight 25% on utilities. The system of solenoid valves and optional tanks, pumps and filters is engineered for long trouble free life & fool proof operation. The machine construction allows delivery of vials into a separate room or attach directly with tunnel.

    more..
  • Best Deals from Linear Vial Washing Machine

  • Automatic Linear Vial Washing Machine

    Automatic Linear Vial Washing Machine

    Get Price Quote

    AUTOMATIC LINEAR DOUBLE TRACKS VIAL WASHING MACHINE MODEL : AHVW 120, AHVW 60 Operations: • The vial trays are directly un-loaded to the vial tray from which vials directly transfer to the turn-table. • The turn table slowly transfer vials to the linear washing machine in single track or two tracks feed warm, from where vials are automatically come in to invert position. • The synchronized star- wheel places two vials at a time in two tracks indexing chain or one vials in to the single track machine. • The indexing chain positively carries inverted pair of vials through seven sequential washes. • At the end of washing operation vials are re-inverted back into original and collected in the tray. Pumping station: Tank with valve – 3 NOS. SS 316 pump – 3 NOS. S.S. Filter housings and filter cartridges. Change parts: Change over of each vial size contain star wheels, worms, inverters./div> Technical specifications: SS finish gmp model Dimension: 1600mm l >< 800mm w>< 800mm h Electrical: single phase Output: 3000- 4000 vials per hours in case single track machine 6000- 8000 vials per hours in case double track machine

    more..
  • Linear Vial Washing Machine

    Linear Vial Washing Machine

    Get Price Quote

    Automatic linear vial washing machine is used for washing of vials. There are two models available one is sblvw-120 which gives an output speed of 60 to 120 vials min. & the other one is model sblvw-240 which gives an output speed of 80 to 240 vials min.sblvw-120 240 automatic linear vial washing machine is used for washing of vials. There are two models available one is sblvw-120 which gives a out put speed of 60 to 120 vialsmin. & the other one is model sblvw-240 which gives a output speed of 80 to 240 vialsmin.vials will be pushed from infeed tray and then move on wire woven conveyor belt, which align the vial in correct position, to enter in to the carrier pocket with help of oscillating guide rails. Oscillating arm deliver the vial inside pocket in mouth down position over spraying nozzles. Multijet sprayers fixed at the top cause the total external and internal surface to be washed. To avoid any possible cross contamination between two different waters. Each washing station is provided with an independent circuit. Carrier pocket is moving with indexing motion. When the baskets have completed their motion the needles are lifted. They penetrate the vials, spraying jets of water or compressed air then return down. The baskets movement then advances by one station. Each station of vials passes through the washing cycles selected.