urology disposable
Uroflowmetry System
uroflowmetry or urine flowmetry is one way of integrating the activity of the bladder and the outlet during the emptying phase of micturation. The micturation process consists of detrusor function of bladder neck opening and urethral conductivity. It can establish the type of abnormality and filter the patients who require further invasive procedures. Thus, it avoids under treatment in the younger age group & restricts overzealous invasive procedure in the older age group. when the micturation process starts, a volume change is sensed by the microprocessor based device automatically, which determines and stores urinary volume, flow rate and time along with other parameters. At the end of micturation process the microprocessor based device programmed to determine parameters relating to urinary flow like voided volume, voiding time, flow time, maximum flow rate, average flow rate and time to maximum flow. It also provides the graphical flow curve of the micturation process by the means of flow rate v/s time. At the end of micturation process, by automatic preset delay, it gives a printout which consists of a graphical flow curve as well as statistics relating to parameters of urinary flow altogether with the patients information.
...moreuroflowmetry machine
uroflowmetry
We are the Manufacturer of best Quality Urological Products (A Complete Urology Solution)
...moreUrine Collection Beakerurine Collection Beaker
The duly calibrated urine collection beaker is made of special grade, transparent plastic which can be placed easily below the micturation chair. This urine collection beaker is reusable and having capacity of 2000 ml. (max.)
...moreUreteric Catheter
ureteral stents
URETERAL DILATORS SET
Ureteral Dilator Set
Used for dilation of ureter prior to ureterorenoscopy and also for sequential (step by step) dilation of the intramural tunnel and ureter and or stone manipulation. Features Smooth surfaces for ease of introduction. Uniform taper to reduce trauma.
Length : 70 cm
...moretransducer
It is highly accurate, piezo resistive and cost-effective digitally controlled weight based flow transducer.
...moreSTONE RETRIEVAL BASKET STAINLESS STEEL WIRE
stone retrieval basket
stone retrieval basket used to remove multiple stone fragments from ureter with semi rigid endoscope. Features Maximum patient safety and compatibility. easy to operate.
...moreProbe
Rigid lithotripsy probes are available in all sizes and compatible with any ureteroscope and nephroscope. Cost effective and durable. Sterilization : Formalin chamber OR Cidex. Probes for Ureteric stones : 0.8 mm; 1.0mm; 1.2mm; 1.4mm – Length : 610mm Probes for kidney and bladder stones : 2.0mm; 2.5mm; 3.0mm – Length : 450mm
...morePneumatic Lithotripter
It is microprocessor based digitally controlled pressure flow device, which generates high accurate pluses in single pulse mode as well as variable continuous pulse mode for the fragmentation of stones in urinary system, i.e., Kidney, ureter and Bladder. One of the marked and distinctive feature of “NIDHILITH Digi” is its rigid probe design. This results in rapid and safe fragmentation of the large and hard calculi situated anywhere in the urinary system i.e. kidneys, ureters and bladder. Therefore, there is no heat generation threat on the tip of the probe and following damage to the mucosa. NIDHILITH Digi is mainly having four parts i.e. Control Unit, Oxygen Regulator orAir Compressor, Handpiece and Rigid Probe. It is a foot switch operated highly precise microprocessor based electro pneumatic device, operated with a standard electrical supply as well as clean and dry compressed air. It is connected with the hand piece through flexible tubing. The rigid probe is connected to hand piece. The probe tip is placed in direct contact with the stones. As soon as the control unit energizes by the foot switch, the compressed air enters the hand piece and propels a small piston against the base of the probe at a frequency from 1 cycles/sec to 12 cycles/sec. The ballistic energy is then transmitted through the probe into the stone, thereby fragmenting the stone. Due to the design of rigid probe, generally NIDHILITH Digi is recommended for use with the rigid or semi rigid endoscope having straight working channel.
...moreNIDHILITH VAC
NIDHILITH VAC is an additional component for use with NIDHILITH Digi- Intra Corporeal Pneumatic Lithotripter via suction hand piece, hollow probes and hand switch for PCNL & URS. Features It provides a better endoscopic vision as well as, ideal and safe stone location for disintegration in Ureter, Kidney and Bladder during lithotripsy. During and also post lithotripsy, suction is provided for remaining fragments and stone-dust of ureter, kidney and bladder stones.
...moreMONO J STENT KIT
Micturation Chair & Funnel
This handy micturation chair comes with back and arms rest to avoids physical and psychological discomforts to get habitual pattern of micturation during flow measurement.
...moreMalecot Nephrostomy Catheter
The Malecot nephrostomy catheter is placed percutaneously through an existing nephrostomy tract. It is used for nephrostomy drainage in the renal pelvis. Features Smooth passage in tortuous ureter.
...morelithotripter
Led Light Source
FEATURES This light source is used in Sinoscope, Microscope, Laparoscope, Resectoscope and Arthroscope. Working Environment Temperature 5~32C Relative humidity: Less than equal to 70% Atmospheric pressure: 86.0 ~106.0 kPa
...moreJet Pump
Guide Wire
Fascial Dilators Set
Endopyelotomy Stent
Be first to Rate
Rate ThisOpening Hours