WELDING CABLES
We are offering welding cables. The cable has high flexibility subjected to light, ozone, oxygen, nert gas, and oil, and it is also resistant to the effects of cold, heat, and fire. Suitable for use in open air, in dry as well as damp interi-ors. The high degree of flexibility does not form knots on the cable which could lead to internal break of conductors. in welding cable , a highly flexible elastomeric pvc jacket surrounds fully annealed rope-stranded bare copper. The insulated flexible cables are use to connect welding machines. The heavy duty welding cable is resistant to flame, oil, abrasions, tar and grease. test voltage : 1000v minimum bending radius : 5x cable diameter.
Brand Name : R R Kabel
...moreUninyvin Cables
1000 Meter (MOQ)
We are offering uninyvin cables. These cables are manufactured with insulation of hr pvc and braided with glass fiber and overall braided by nylon fiber and lacquered with nylon varnish. Such cables withstand high temperature. Their usage is mainly in ups, aircraft wiring, dg panels due to low weight. Such cables are resistant to ester based fluids(hydraulic oil), acids, chemical sand solvents. The nylon and glass fibers are also very good heat resistant materials. Fine annealed tin coated copper strands voltage rating ‐ is 10241 part 3 is 8130 strands as per is 10241 part 3 test voltage is 10241 part 1 special core insulation temperature ‐35°c to 105°c hr pvc 105 °c braided with glass fiber 100% coverage second layer of braid with nylon fiber the overall construction is finally lacquered with nylon varnish
...moreSolar Cable
1000 Meter (MOQ)
We are offering solar cable. Solar cable ( 30 days in saturated ammonia atmosphere (internal testing) rr kabel solar cables are interned for use in photovoltaic power supply systems and similar applications as free free hanging, movable, fixed installation and buried in ground in constructional covered systems. The cables can be used indoor, outdoor, in hazard explosion areas, in industry and agriculture. They are suitable for applications in equipment with protective insulation(protecting class ii) flame propataion ozone resistance according to din en 50396 test type b, hd 22.2 sinble cable according to din vde 0482 part 332-1-2, din en 60332-1-2 test type b uv-resistance according to ul 1581 (xeno-test), multiple cable according to din vde 0482 part 266-2-5, din en 50305-9 iso 4892-2 (method a) and hd 506a1-2.4.20 low smoke emission according to din vde 0482 part 268-2, absorption of water (gravimetric) according to din en 50268-2 (light transmittance > 70% ) din vde 0473-811-1-3, din en 60811-1-3 corrosivity according to din en 50267-2-2 toxicity according to din en 50305, itc-index < 3
Brand Name : R R Kabel
...moreExhaust Fans
We are offering exhaust fans. designed to effectively combat pollution , exhaust fans quitely and efficiently draw away smoke , odours , dust, dampness and stale air , thus allowing breeze of fresh air into envionment. These fans perfectly compliment the breeze of ceiling and deskwall fans by providing a comfortable atmosphere inside with a constant supply of healthy fresh air. specifications : fan sweep : 300mm (12"), 380mm (15"), 450mm (18") and 600mm(24"). fan motors : 4,6 or 8 pole, single phases, cap start or three phase induction motor. power supply : standard : 220250 v, single phase 50 hz 380440 v, three phase 50 hz optional : 220250 v ,single phase 60 hz 380440 v, three phase 60 hz finish standard : epoxy powder coating military green. option : optional colour , mcq - 200 nos. bearing : doublesealed (zz) ball bearing. features : * wide range to sweeps to choose from , with suitability for single or three phase ac supply. * reversibility by change of blade mounting. * metal frame with rubber mounting for silent operation. * heavy duty, totally enclosed , energy efficient , 2 ball bearing induction motors. * long lasting epoxy powder coating. * availability of accessories like front back protective guard for safety and sqaure gravity louvers. * generally conforming to is : 2312 - 1967. applications : factories , warehouses , chemical and pharmaceutical industries , hotels , theatres and auditoriums, paint shops , dairies and food processing units. The exhaust fans are also used as astandard equipment in desert coolers, paint booths , transformers etc.
Brand Name : R R Kabel
...moreAir Circulator Fan
We are offering air circulator fan. a robust and heavy duty oscillating type propeller fan comprises of aerodynamically designed three blade aluminum pressure die cast impeller , sturdy close-mesh guard, energy efficient motor in an epoxy powder coated finish. specifications : fan sweep : 450mm (18"), 600mm(24"), 750mm(30") fan motor: 4 pole (standard) 6 pole (optional), 1 phase capacitor or 3 phase induction motor. power supply : standard : as under 220250 v, single phase 50hz 380440 v, three phase 50 hz optional : 110v60hz, 230 v60hz finish standard : epoxy powder coating military green bearings : zz ball bearings. features : aerodynamically designed blades for higher air delivery and minimum noise level. dynamic balancing of blades. adjustable height for pedestal model. power consumption limited to bare minimum. generally conforming to is : 2997-1964. applications : airports, auditoriums, bus depots, conference halls, factories, heat treatment shops, offices, pandal decorators, public places, railway stations, restaurants, theatres.
Brand Name : R R KABEL
...moreBraided Cable
We are offering braided cable. * anneal plain flexible copper * special grade of pvc insulation * colored cores upto 4 cores * black cores with white marking for 5 cores and above * cores twisted suitably to form a round shape * covered with insulating plastic foil * screen braiding generally of 65-70% with fine annealed tin copper * special grade pvc outer sheath * sheath color grey black braided cables are most suitable for interconnection of electrical measuring devices to instument panel or instrument. They are used for measuring , monitoring and controlling machine tool manufacture, plant engineering and in all places where electrical interference fields can distort a signal transmission. min. Bending radius : flexing : 20x cable diameter fixed installtion : 6x cable diameter test voltage : corecore : 4000v coreshield : 2000v rated voltage : 300500v.
Brand Name : R R Kabel
...moreShielded Cable
We are offering shielded cable. Constuction conductor : annealed copper wires according to class 1 or 2 or 5 of bs en 60228 insulation : pvc types ti51 according to bs en 50290-2-21 pairs - twisted identification pairs : blue & white. Blue cores indicate pair identification. assembly : concentric layers outer sheath : pvc type tm51 according to bs en 50290-2-22 marking : rr kabel n x m x csa 300500 v pas 5308-part 2 application : pas 5308-2 design guidelines standards : ec 60332-1 flame retardant shielded cables are used in security systems as it provides protection from power frequency and radio frequency interference, thus, reducing the number of false alarms being generated. For its optimum use it necessary to keep the data or signal cables physically separated by at least 3 inches (75 mm) from 'heavy' power circuits which are in parallel.
...moreTesys D Control Relays
25 Piece(s) (MOQ)
We are offering tesys d control relays. more than 85 year of continuing innovation. tesys d : tesys d control relays . tesys d power contactors (3 pole). tesys d low consumption contactors. tesys d power contactors (4 pole). tesys d capacitor duty contactors. tesys d - accessories . tesys d spare coils acdc. tesys d thermalelectronic overload relays tesys mpcb : tesys motor circuit breakers. tesys motor circuit breakers accessories. tesys d control relays • conformity to international standards - iec, ul, csa, ce • up to 5 inbuilt auxiliary contacts • high temperature limits. power contactors - d model (3 pole ac & dc control) • conformity to international standards – iec, ul, csa, ce • 9-150 amps, 3 and 4 pole versions, acdc coils • high temperature limits • different levels of power and control contacts • inbuilt 1 no + 1 nc auxiliary contacts • high electrical life • fuse-less type 2 coordination charts available dc low consumption contactors (3 pole) power contactors - d model (4 pole ac & dc control) • conformity to international standards – iec, ul, csa, ce • 20a to 250a ac1 rating • in-built 1no+1nc auxiliary contact • high temparature limits capacitor duty contactors (ac control) • special contactors designed for switching 3phase capacitors • conformity to iec standards • • 1no + 1nc inbuilt auxiliary contact accessories - for d model contactors (1) suitable for mounting on d model range ac coil contactors and control relays only (2) with switching time of 40 ms between opening of the nc contact and closing of the no contact recommended for star - delta starters thermal overload relays - d model • conformity to international standards – iec, ul, csa • range available - 0.1a to 104 a • direct mounting on contactors is possible upto 95a • higher operating temperature • tripping class 10a & 20a available electronic relays - d model • conformity to international standards – iec, ul, csa • higher operating temperature up to 55ºc • tripping class selectable on product.
Brand Name : Schneider Electric
...moreEasypact Moulded Case Circuit Breakers
We are offering easypact moulded case circuit breakers. Unique kit solution, optimally designed with your safety in mind !! tested and compliant with iec 61439-1 & 2 fully integrates schneider electric switchgear standardized & tested switchboard solution designed as per iec 61439-1 and maximum short circuit withstand 85ka1sec device layout completely in line with thermal and electrodynamic performance pre fabricated, modular, kit design two versions: wall mounted and floor standing for applications upto 4000a attractive design safe, reliable and easy : schneider electric global mccbs offer cross bolted termination starts from 15a make installation more safe isolation feature ensure operator safety class ii front face as per iec 61140 compliance to rohs (restriction of hazardous substances) safety of operator and electrical installation is utmost priroity safe insulated accessories installation auxiliary switch alarm switch combined auxiliary & alarm switch shunt trip coil with thermal magnetic trip unit (tmd) conforms to iec60947-2 suitable for isolation suitable for easypact busbar system easypact range busbar systems available for 250a, 400a & 630a main incoming current available for 4,6,8 & 12 ways (3-pole) easypact 100a (max) outgoing mccbs ez busbar rated 400a and 630a can accept the 2 ways or 4 ways branch extension for upto four additional 250a max outgoing circuits easypact cvs easy choice for quality and value 16a - 800a, 3p & 4p only three frame sizes ics= 100% icu for the entire range isolation with positive break indication class ii front face unique double break contacts moulded case circuit breakers for distribution network with thermal magnetic trip unit (tmd) ics = 100% icu as per iec 60947-2 suitable for isolation transparent cover for trip unit as standard class ii front face single frame size 16-250a accessories for easypact cvs 100 - 630a indication contacts voltage release direct rotary handle extended rotary handle
Brand Name : Schnieder Electric
...morePush Buttons, Led Indicator
We are offering push buttons, led indicator. Pressure switches limit switches harmony control & signalling units xb5xb7 series: biometric switch.
Brand Name : Schneider Electric
...moreOverload Relay
We are offering Overload Relay. Overload Relay Thermal overload relay • Conformance to IEC 60947-4-1, CE Marking • Trip Class: 10A EasyPact TVS Motor Protection Circuit Breaker • Conforming to IEC 60947-2-3-4 • CE Marking • Breaking Capacity up to 100 kA Thermal Overload Relays - LR2-K Model (Direct Mounting) • Conformity to International Standards – IEC, UL, CSA • Range available - upto 0.1A to 16A • Direct mounting on contactors is possible upto 16A.
Brand Name : Schneider Electric
...moreDistribution Boards
We are offering distribution boards advanced communication technology that inspires.. modular circuit breakers - xc60 !"breaking capacity as per iec 60898 and isiec 60898, icn = 10ka !"breaking capacity as per iec 60947-2, icn = 15ka, upto 40a !"higher installation life : energy limitation class: 3 !"tropicalization: t2 - relative humidity 95% at 55oc !"higher performance by low cost : cascading* !"increase system continuty : discrimination* !"reference temperature of 50oc as per iec60947-2# modular circuit breakers - c120 !"breaking capacity as per iec 60898, icn = 10ka15ka !"positive break indication !"degree of pollution: 3 (suitable for industrial environment) !"operating temperature: -30 to 700c !"terminal connections: # flexible cables up to 35 sq. Mm # rigid cables up to 50 sq. Mm reference temperature 500c as per iec 60947-2 residual current circuit breakers (rccbs) - xid complies to standards iecen 61008-1 and is 12640 ac class selective range available for time based discrimination immune to nuisance tripping due to transient over voltage (lighting, switching surges) easy monitoring: earth fault indication on front face mandatory to use of-s auxiliary to add any indication or tripping auxiliary modular distribution degree of protection: ip43 for double door and ip30 for single door detachable chassis gives ease and comfort in internal wiring cement spill protector (csp) ensures no dust or cement particles will enter dbs optimized dimensions providing enough wiring space stoppers on din rail dbs are provided with complete wire set, insulated busbars, labels, cable ties, blanking plates and csp (wire sets and busbars not provided in tier db’s) enclosures, distribution boards and p&s units have the provision for mounting modular devices as shown in the photograph. ppi distribution board (tpn ) - horizontal format.
...moreCopper Bars
Copper Cathodes
Copper Rods
Copper Strips
Be first to Rate
Rate ThisOpening Hours