Thermal Overload Relay
vSalient Features All relays are bearing ISI mark as per IS/IEC 60947 (Part-4/Section-1) . Relay cover full range of current PK - 1 : 2.5 Amp to 14 Amp. PC - 1 : 1 Amp to 18 Amp. PC – 2/3 : 9 Amp to 42 Amp. The triple pole bimetallic thermal overload relay is of the hand-reset type. It unmistakably indicates overload. A temperature compensation device prevents the relay from being affected by variation in ambient temperature. The entire relay unit is housed in Bakelite enclosure and is accurately calibrated and individually tested on an automatic test bench. Setting can be adjusted by means of a pointer. Satisfactory operation at all ambient temperatures from –5 ᵒC to 55 ᵒC with the help of temperature compensating device. PK1, PC1, PC2/3 relays are manual reset type. These relays are provided with auxiliary contacts having thermal capacity of 6A and 2A, AC-15 at 415V, 50Hz. These relays are suitable for direct mounting on Type PC contactors. PK1, PC1, and PC2/3 relays are suitable for trip class of 10A as per IS: 60947 (Part-4/Section-1). Compact and most reliably designed.
...moreswitch disconnector fuse unit
Salient Features As Per IS/IEC 60947-3. Utilization Category - AC23A. Quick make - Break Mechanism. Compact Size. Clear ON/OFF indication. Easy Inspection and replacement of contacts. High Clearence and creepage distance. Front Operated mechanism. Sturdy Hinge which opens the door upto 180 degree.
...moreStar Delta Motor Starters
Star-delta starters are available in Semi-Automatic (SASD) and Fully Automatic (FASD) version. FASD Starters – The motor starts in ‘Star’ when the green button is pressed and a timer automatically performs the change over to ‘Delta’. SASD Starters – The motor starts in ‘Star’ when the green button is pressed and the change over to ‘Delta’ when the button is released. This button must only be released when the motor reaches the normal speed. In both types of starters, the construction features and performance are identical. Type PK and PC Star-Delta Starters have three contactors (either Type PC or PK1 contactors) and one bimetallic Thermal Overload Relay (Type PC/PK1/PNR) suitably wired and interconnected. Salient Features Conforms to IS/IEC : 60947(Part 4/Section1). Type PK1 starters consist of a Type PK1 Contactors and Thermal Overload Relay each bearing an ISI Mark. Type PC starters consist of a Type PC Contactors and Type PC/PNR Thermal Overload Relay each bearing an ISI Mark. Most Reliable motor protection widely accepted in Agricultural as well as Industrial sector. Guaranteed performance is assured due to world-Class design and quality manufacturing of the starters. Contactors and Relays are manufactured to withstand high ambient temperature, humidity and under voltage conditions. Exceptionally long contact life of Air Break Contactor used in Motor Starter due to silver alloy contact tips and bounce free contacts. Suitable for copper as well as aluminum conductors as per Indian Standards. The enclosure is dust proof and has knockouts at the top and bottom for taking conduit or screwed packing glands. Due to powder coating, the enclosure surface is highly anti-corrosive and bears smooth, elegant finish. The sheet steel enclosure is robust, specially designed, Fabricated and powder coated to withstand adverse climatic condition. These starters are complete with all internal wiring. OFF Push button can be latched in OFF position to prevent accidental starting. Spare Kit containing Main and aux. contacts available at nominal price. Wide range of coil voltages available. Remotely controlled operation possible and can also be operated through limit switches, float switches, pressure switches, etc. Earthing screws provided for protection. Elegant in appearance and design.
...moreDOL Motor Starters
Salient Features Fully conforms to IS/IEC : 60947(Part 4/Section1). Type PK1 starters are ISI Marked. These starters consist of a Type PK1 Contactor and Thermal Overload Relay each bearing an ISI Mark. Type PC starters consist of a Type PC Contactor and Type PC/PNR Thermal Overload Relay each bearing an ISI Mark. Most Reliable motor protection widely accepted in Agricultural as well as Industrial sector. Guaranteed performance is assured due to world-class design and quality manufacturing of the starters. Contactors and Relays are manufactured to withstand high ambient temperature, humidity and under voltage conditions. Exceptionally long contact life of Air Break Contactor used in Motor Starter due to silver alloy contact tips and bounce free contacts. Suitable for copper as well as aluminum conductors as per Indian Standards. The sheet steel enclosure is robust, specially designed, Fabricated and powder coated to withstand adverse climatic condition. It also acts under voltage release and protects motor from the effects of low voltage operations. OFF Push button can be latched in OFF position to prevent accidental starting. Wide range of Thermal Overload Relays, which can operate within temperature range of –5 ᵒC to 50 ᵒC ambient. Wide range of coil voltages available. Remotely controlled operation possible. 2 Nos. Earthing screws provided for protection. Elegant in appearance and design.
...moreAC Air Break Contactors
Salient Features Fully confirms to IS/IEC: 60947 (Part 4/Section 1). Contactors type PK-1, PC-0, PC-1, PC-1.5, PC-2, PC-3, PC-4, & PC-6 are ISI marked. Type PK1 contactor is 4 Pole and Type PC is 3 Pole. These Contactors consist of a fixed contact system with a magnetic core, solenoid coil and a moving contact system with an armature. Robust and Sturdy design. Provides Trouble Free and Noiseless Operation. Exceptionally long contact life under severe condition due to bounce-free double break design and silver alloy contact tips. 2 NO + 2 NC auxiliary contacts is a standard feature.( Add on Contact blocks in case of PC-8, PC-10 to PC-12 ). The Main, Auxiliary contacts and coil are easily accessible for inspection and replacement purpose. The unit can be mounted in any position on Vertical / Horizontal plane. Magnetic Cores have a very low loss and are provided with shading rings to reduce chattering and humming. Wide ranges of Coil Voltages are available. In PC-1.5, shroud is a standard feature and shroud is optional in case of PC-0 and PC-1 Contactors. Spare kit containing Main and Auxiliary contacts are available at nominal Price.
...moreHRC Fuses
fuse base
Brass Parts