Reverse Osmosis System
Get Price Quote
We are offering reverse osmosis system. Landmark considers your inlet water quality and capacity requirements and offers you optimised combination. This choice is dependent on different flux rates, pump models, membrane types and inlet water quality.
Reverse Osmosis System
Get Price Quote
We are offering reverse osmosis system. principle of reverse osmosis system reverse osmosis (ro) is the process, in which water is pressurized through a semi –permeable membrane. As a result of this, as shown in the below depicted schematic diagram, water will pass through the membrane surface while the dissolved and particulate materials are left behind. When the pressure is applied to the concentrated solution, water is forced through the membrane from the concentrated side to the dilute side. This process is known as“ reverse osmosis.” reverse osmosis (ro) is a process of physical separation of dissolved solids and minerals present in water. This technology uses the principle of osmosis, wherein the mineral concentration of raw water is reduced by applying high pressure through a semi-permeable membrane. ro technology offers maximum flexibility to meet diverse requirements. Our customised software, landmark helps customers gain the maximum 'ro advantage', by helping to make the right selection. landmark considers your inlet water quality and capacity requirements and offers you optimised combination. This choice is dependent on different flux rates, pump models, membrane types and inlet water quality. It gives the right solutions, reduced what is reverse osmosis system? the reverse osmosis system is composed of two major parts, high pressure pump and the r.o. Membranes. The initial purified water production rate is measured at this pressure. it appears that there are long term benefits to be gained by operating at lower percent water recovery, particularly in reducing maintenance to the systems and minimizing precipitation problems which may arise due to operator error. it is important to realize that the purified water from a reverse osmosis system is delivered essentially at atmospheric pressure, usually to a vented storage tank. In general, it cannot be operated by opening and closing valve in the product water line (unless special pressure relief is provided). The reason for this is that the high pressure in the system drives the water across the membrane. And no flow of water would be possible if the pressure on both sides of the membranes were same. If, for some reason, the product water line is closed, while the system is operating, the pressure would build up. Of course, if the purified water side of the system was strong enough, the pressure would end up the same as the pump pressure, but at that point, no water would flow across the membrane. In reality, the p.v.c. Piping on the product water side normally would not tolerate such high pressure. the membrane is capable of taking 600 psi of “forward pressure”. I.e. From the direction of the supply water side to the purified water side. However, they are susceptible for it’s tolerance limit for “ back pressure.” i,e, from the direction of purified water side to the supply water side.” so, one should take care while operating the system. the quality of purified water produced by reverse osmosis process is roughly a constant percentage of the feed water. For example, if the feed water is entering at 50 ppm , the purified water may be about 1 to 2 ppm. (i.e. 96.00 to 98.00% rejection of dissolved minerals.). For another example, when the feed water is entering at 500 ppm, the purified water would be from 10 to 15 ppm. Usually a conductivity meter or tds meter is used to measure the mineral contents. the membrane based technology the application of reverse osmosis to the solution of problems in water treatment requires an understanding of the basic mechanisms involved in the process, the limitations of reverse osmosis and the pre treatment requirements. reverse osmosis utilizes the unique properties of a “imported” semi- permeable membrane to allow fluid to pass while restricting the flow of dissolved ionic material. With pressure applied to impure water on one side of such membrane materials, pure water will pass through, leaving most of the impurities behind. The rejection of the dissolved ionic material is a function of both molecular weight and ionic charge. For example, we can expect a nominal 90 % rejection of sodium chloride, which means that the product water passing through the membrane will have a concentration of salt approximately one-tenth that if the feed water. The rejection of calcium carbonate (hardness) will be nearly 95%. While most metallic salts will be rejected at a rate of 98% to 99%. the rejection of non- ionic or organic material is primarily done by mechanical filtration. advantages compact and modular ro blocks easy installation, operation and servicing specific selection possible from a wide range high level of plant automation visual monitoring system (vms) for ease of trouble-shooting stainless steel multistage centrifugal pump; inline suction and delivery allows easy maintenance and access online product water quality monitoring membrane and pump protection features minimum pipe length to reduce system resistance easy servicing with qrc (quick release coupling) material of construction: pvcss application ceramic chemicals dairy fishing food & beverages hospital hotel pharmaceutical pulp & paper textile
Best Deals from Reverse Osmosis Systems
250 LPH Domestic Reverse Osmosis System
75,000 Per Piece
Desalination Reverse Osmosis System
650,000 Per Unit
Reverse Osmosis System
10,000 Per Unit
1 Unit (MOQ)
We are supplier of Reverse Osmosis System
Kent Superb
Get Price Quote
Healthy Companion No need to compromise on your health with the risk of water borne diseases as the Kent Water Purifier with the RO + UV +UF technology provides for double purification by removing the dissolved impurities like chemicals and salts. All the necessary minerals are maintained with the TDS controller technology which ensures that you will consume safe drinking water. The Kent W-Purifier Superb RO Smart is technologically capable of purifying water from all sources, be it a bore well, water storage tank or even municipal tanks. The Mineral RO Technology adjusts the TDS level to provide the purified water effectively breaking the myth RO purifier being good enough only for raw water with more than 500 ppm TDS level. All Round Performance With a capacity to store 9 litres of purified water, you need not have to worry about running out of water, as it keeps on working even in the absence of electricity or running water. It also comes with a unique water level indicator. The Kent water purifier ensures all round safety as the water stops purifying if the UV lamps are not replaced. Once the interface shows the message of UV failure, the purifier needs to be switched off as the filter will need to be replaced with only 60 hours of purifying life left in it. You will be notified about the replacement with the ‘Replace Filter’ message.
Reverse Osmosis System
Get Price Quote
Our standard Brackish Water Reverse Osmosis systems are available with capacities ranging from 250 GPD to 5000 GPD, and our standard Seawater Reverse Osmosis systems or water makers or RO desalination systems are available with capacities ranging from 380 GPD to 180,000 GPD.
Commercial Reverse Osmosis System
Get Price Quote
Commercial Reverse Osmosis System, Water Purifiers, water purification plants
Reverse Osmosis System
Get Price Quote
Reverse Osmosis System
Get Price Quote
reverse osmosis water purification system
Get Price Quote
reverse osmosis water purification system, drinking water purification system
Industrial Reverse Osmosis Systems
Get Price Quote
Industrial Reverse Osmosis Systems, Dosing Systems, Reverse Osmosis Systems
Reverse Osmosis System
Get Price Quote
liquid tanks
commercial reverse osmosis systems
Get Price Quote
commercial reverse osmosis systems, RO Water Purifiers
Reverse Osmosis System
Get Price Quote
automobile battery containers, battery containers