EMI Protected Halogen Free Control Cables
Get Price Quote
Cable Structure• Class 5 bare copper conductor as per IEC 60228 and IS 8130• ZHLS Insulation• Cores twisted• Polyester tape binded• Fine wire ATC braid• ZHLS outer sheath, grey Standard References BS EN 50525-3-11 BS EN 50288-7 Special Features Low bend diameter Flexible Space saving construction Excellent fire retardance Low halogen content Excellent electrical properties Good oil resistance Low smoke and toxicity Excellent EMI protection Application Range Industrial machinery and air conditioning systems For general purpose installations in dry environment subjected to low mechanical loads Areas where human or animals are present Tunnels and transportation Suitable for outdoor installations For installation near electro-magnetic noise – near power cables, heavy power consuming machinery and appliances Measurement and control Data processing and signaling Technical Data Temperature Range -15°C to +70°C Nominal Voltage 300/500V Test Voltage 1500V Insulation Resistance Min. 200Mohm-km Min. Bending Radius 8 x cable dia Short Circuit Temperature Upto 160°C Flame Retardance As per IEC 60332-1
PVC Insulated Copper Cables
Get Price Quote
Cable Structure Class : 2 Stranded Copper Wire As Per IS:8130 Insulated : PVC (Polyvinyl Chioride) type A or C As per IS:5831 Core Identification: 1 Core : Black / Red / White 2 Core : Black,Red 3 Core : Red,Yellow,Blue 4 Core : Red,Yellow,Blue,Black 5 Core : Red,Yellow,Blue, Black, Grey 6 Core & Above : Two adjacent cores(Counting And direction cores) in each Layer,Blue & Yellow,remaining cores Grey. Inner Sheath : PVC (Polyvinyl chioride) ST1 or ST2 Grade as Per IS:5831 Armouring : H.D.Aluminium / G.I. wire as per IS:3975 Outer Sheath : PVC (Polyvinyl chioride) ST1 or ST2 Grade as per IS:5831 Standard References IS:1554/Pt. 1/1988 Special Features Very High Physical Strength Requires Less Space for Installation Better Fire Properties than XLPE Variant Better UV Properties than XLPE Variant Variants : FR FRLS HR-85 Degree Application Range General And Industrial Application Plant Wiring Under And Ground Cables Which Require High Physical Strength Technical Data Temperature Range : -15°C to +70°C Test Voltage : a.c.3 KV (rms) Insulation Resistance : 1 x 1013 ohm-CM Min. Bending Radius : 12 x OD (OD = Overall Diameter of Cable) Short Circuit Temperature: 160°C Voltage Rated : 650 / 1100 Volts DIMENSIONAL TABLES,POWER CABLES – COPPER / PVC / STRIP ARMOURED / PVC, TABLE – 1 SINGLE CORE COPPER CONDUCTOR PVC INSULATED & PVC SHEATHED H.D.AL.STRIP ARMOURED CABLES ACCORDING TO IS : 1554/PT. 1/1988
Best Deals from Industrial Wires
Pvc Cables
Get Price Quote
Pvc Cables, PVC Wires