Hematology Analyzer Dealers in Saha, Ambala

(8 products available)
  • Electrophoresis Vertical

    Electrophoresis Vertical

    Get Price Quote

    • Brand Name: ALPHA CHEM
    • Model Number: ALPHA CHEM-206

    We are offering electrophoresis vertical : it is required in biotechnology, molcular biology applications in colleges, universities, research institutes. It is meant for protein characterization. The unit is jointless, moulded of transparent polycarbonate to avoid leakage. The unit is based on acrylic sheet fitted with 3 leveling screws. Complete with acrylic cover. Specification dimensions outer 15x18x15 cm. (lxwxh) gel size (cm) 8x7 (1gel) buffer required (ml) 100 + 150 platinum electrodes 2 nos. Supply complete with standard accessories likes: wires glass plate-1 and 1 notched rectangular total 2nos. One set spacers of 1.0mm,1.5mm - 4 pcs. Each 4 sets of nylon moulded combs of 7 wells & 10 wells in 0.1mm and 1.5mm thickness silicon gasket - 1 no also available vertical and horizontal models.

    more..
    Alpha Chem
    Saha, Ambala
    0.0 View Profile
  • Microprocessor Hemoglobin Meter

    Microprocessor Hemoglobin Meter

    Get Price Quote

    ALPHA CHEM- 325  Microprocessor Hemoglobin Meter Microprocessor Hemoglobin Meter is used to determine the hemoglobin concentration in the blood sample. The measurement hemoglobin concentration is carried out at wavelength of 546 nm. Using state-of-the-art LED technology the green light produced is projected through the sample and measured by sensitive photodiode. The measurements are made using cyanmet hemoglobin method used through the world.   Heamoglobin is an iron-containing protein found in the red blood cells .It enables the red cells to carry oxygen from lungs to the rest of the body and carry carbon dioxide back. The haemoglobin level indicates the blood’s oxygen-carrying capacity and can play a major role in the early diagnosis of many illnesses such as thelsemia, sickle cell anemia, leukemia, malaria and hook worm etc.   Specifications   Measuring Method Cyanmethemoglobin   Measuring Range 0 - 30 gm/dl of Hb.   Dilution Ratio 1:25 I   Sample Volume 1 ml   Display 3 Digit 7-Segment Red LED Display   Wavelength 546 nm   Keyboard 3 Keys, Soft Touch Memebrane Type   Zero Setting Automatic   Calibration Automatic   Detector Highly sensitive silicon photodiode   Power230 V ± 10% AC, 50 Hz   Dimensions (L x B x H)  195 x 235 x 105 mm (Approx.)   Weight 2.5 Kg. (Approx.)   Accessories   Matched Test Tube: (A set of 5), Spare Lamp, Operation Manual and Dust Cover

    more..
    Alpha Chem
    Saha, Ambala
    0.0 View Profile
  • Best Deals from Hematology Analyzer

  • Blood Chemistry

    Blood Chemistry

    Get Price Quote

    • Application: Clinical Use
    • Color: Grey
    • Feature: Highly Competitive
    • Automatic Grade: Automatic
    • Driven Type: Electric
    more..
  • Digital Hemoglobinometer

    Digital Hemoglobinometer

    Get Price Quote

    • Application: Blood Pressure Reading
    • Certification: CE Certified, ISO 9001:2008
    • Weight: 0-100gm, 100-200gm, 200-400gm, 400-800gm
    • Voltage: 3-6VDC, 6-9VDC, 9-12VDC
    • Condition: New, Used
    • Automatic Grade: Automatic, Manual
    • Driven Type: Battery
    • Measurement Range: 20-280mmHg, 20-285mmHg, 20-290mmHg
    • Feature: Accuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight, Low Battery Consumption, Mercury-free
    • Tube Length: 0-100mm, 100-200mm, 200-400mm
    more..
  • Digital Blood Cell Counter

    Digital Blood Cell Counter

    Get Price Quote

    This cell counter is a reliable, accurate, stable & sleek instrument. It is a Micro controller based and integrated with counting, analysis, monitoring & percentage (%). It is mains & battery operated. This instrument has twelve (12) operating keys and convenient for clinical labs showing the primary or virus infections.

    more..
  • Hematology Analyzer

    Hematology Analyzer

    Get Price Quote

    The Hematology Analyzer machine is for 19 parameters & 3 histograms. Automated to increase productivity 3-part differential cell counter with 22 parameter & laser light source Direct tube sampling from collection vials for operator safety Bar code capability to reduce manual input, accurate results More than 60 samples per hour low maintenance required  Total amount of WBC. WBC amount of Lymphocyte Ly Amount of Monocyte MO Amount of Granulocyte GR Lymphocyte percentage Ly% percentage of mononuclear cells MO% Granulocyte percentage GR% total amount of RBC Hemoglobin HGB Hematocrit HCT Mean volume of red blood cells MCV Mean corpuscular hemoglobin MCH Mean corpuscular hemoglobin concentration MCHC RBC volume distribution width Coefficient of variation RDW-cv standard deviation of RBC volume distribution width RDW-sd Total amount of platelet PLT Mean platelet volume MPV Plateletcrit PCT Platelet distribution width PDW White blood cell distribution histogram WBC Histogram RBC distribution histogram RBC Histogram Platelet distribution histogram PLT Histogram 2. Parameters: Use impedance method for RBC and platelet count Cyanide free for Hemoglobin test Flow cytometry +laser light scatter + chemical dye method for WBC differential analysis Fully automated with an autoloader & sampler use both closed tube sampling & open tube sampling 2 counting mode, whole blood & pre-diluted mode With histograms and scatter grams for differential results Throughput of at least 60 samples per hour – Automatic flagging system for abnormal results & automatic sample re-run Automatic validation of results on a dedicated PC with at least a 8” colour monitor Data storage capacity of at least 20,000 results Optional integrated slide maker and on-board cytology atlas Optional colour printer an on-board diagnostics Flexible communication/connection (USB) Operating temperature of 10 oc -35oc and humidity of up to 85% Floppy disc drive & DVD writer  Power 98V-264V  3. Principle of cell counts Instrument measured blood can be diluted to exact proportion by diluents firstly, which is used to measure parameters of WBCRBCPLT & HGB. WBC, RBC count pool diluted samples pass their own porous counting respectively under negative pressure, Amount of fluid that flowing through small hole is specimen volume of instrument for analysis. Instrument measured size distribution & number of WBC, RBC & PLT by using impedance method. Electrodes inserted in holes on both sides of liquid, it sets up a field environment on both sides of surrounding count micro porous, according to blood-cell non-conductive nature, when cells passed count micro porous, it will cause impedance changes, size of impedance changes & proportional to cell volume. Specifications Test Items WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDW—CV, RDW—SD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram Background Count WBC: ≤0.3×109/L RBC: ≤0.03×1012/L HGB: ≤1g/L PLT: ≤10×109/L Linearity Test Item Test Range Allow Difference of Linearity WBC 0∼6.0×109/L ±0.3×109/L 6.0∼99.9×109/L ±5% RBC 0∼0.99×1012/L ±0.05×1012/ L 1.0∼9.99×1012/L ±5% HGB 0∼99 g/L ±2g/L 100∼300 g/L ±2% PLT 0∼99×109/L ±10×109/L 100∼999×109/L ±10% Repeatability Test Item CV(%) Teat Range WBC ≤2.0 7.015.0×109/L RBC ≤0.5 3.56.0×1012/L HGB ≤1.5 110180g/L PLT ≤4.0 150500×109/L MCV ≤0.5 80110fL Sample Volume Twig blood: 20μl Whole Blood: 13μl Sample In store 20,000 samples in store Dilution Ratio WBC/HGB: 1:500 RBC/PLT: 1:50000 Screen 8’’ Touch LCD Screen Interfaces RS232 joint, USB, PS2, Parallel port Test Speed 60 samples/hours Continuous Work Time>8h  

    more..
  • Smart Hemoglobin Meter

    Smart Hemoglobin Meter

    7,799 Per Piece

    5 Piece(s) (MOQ)

    • Warranty: 1 Year
    • Frequency: 50 Hz
    • Memory: Internal Storage Of Smart Phone
    • Wavelength: 540
    • Display: 16x2 Alphanumeric Display
    • Interface: Bluetooth
    more..
  • Hematology Analyzer

    Hematology Analyzer

    Get Price Quote

    The Hematology Analyzer machine is for 19 parameters & 3 histograms. Automated to increase productivity 3-part differential cell counter with 22 parameter & laser light source Direct tube sampling from collection vials for operator safety Bar code capability to reduce manual input, accurate results More than 60 samples per hour low maintenance required  Total amount of WBC. WBC amount of Lymphocyte Ly Amount of Monocyte MO Amount of Granulocyte GR Lymphocyte percentage Ly% percentage of mononuclear cells MO% Granulocyte percentage GR% total amount of RBC Hemoglobin HGB Hematocrit HCT Mean volume of red blood cells MCV Mean corpuscular hemoglobin MCH Mean corpuscular hemoglobin concentration MCHC RBC volume distribution width Coefficient of variation RDW-cv standard deviation of RBC volume distribution width RDW-sd Total amount of platelet PLT Mean platelet volume MPV Plateletcrit PCT Platelet distribution width PDW White blood cell distribution histogram WBC Histogram RBC distribution histogram RBC Histogram Platelet distribution histogram PLT Histogram 2. Parameters: Use impedance method for RBC and platelet count Cyanide free for Hemoglobin test Flow cytometry +laser light scatter + chemical dye method for WBC differential analysis Fully automated with an autoloader & sampler use both closed tube sampling & open tube sampling 2 counting mode, whole blood & pre-diluted mode With histograms and scatter grams for differential results Throughput of at least 60 samples per hour – Automatic flagging system for abnormal results & automatic sample re-run Automatic validation of results on a dedicated PC with at least a 8” colour monitor Data storage capacity of at least 20,000 results Optional integrated slide maker and on-board cytology atlas Optional colour printer an on-board diagnostics Flexible communication/connection (USB) Operating temperature of 10 oc -35oc and humidity of up to 85% Floppy disc drive & DVD writer  Power 98V-264V  3. Principle of cell counts Instrument measured blood can be diluted to exact proportion by diluents firstly, which is used to measure parameters of WBCRBCPLT & HGB. WBC, RBC count pool diluted samples pass their own porous counting respectively under negative pressure, Amount of fluid that flowing through small hole is specimen volume of instrument for analysis. Instrument measured size distribution & number of WBC, RBC & PLT by using impedance method. Electrodes inserted in holes on both sides of liquid, it sets up a field environment on both sides of surrounding count micro porous, according to blood-cell non-conductive nature, when cells passed count micro porous, it will cause impedance changes, size of impedance changes & proportional to cell volume. Specifications Test Items WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDW—CV, RDW—SD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram Background Count WBC: ≤0.3×109/L RBC: ≤0.03×1012/L HGB: ≤1g/L PLT: ≤10×109/L Linearity Test Item Test Range Allow Difference of Linearity WBC 0∼6.0×109/L ±0.3×109/L 6.0∼99.9×109/L ±5% RBC 0∼0.99×1012/L ±0.05×1012/ L 1.0∼9.99×1012/L ±5% HGB 0∼99 g/L ±2g/L 100∼300 g/L ±2% PLT 0∼99×109/L ±10×109/L 100∼999×109/L ±10% Repeatability Test Item CV(%) Teat Range WBC ≤2.0 7.015.0×109/L RBC ≤0.5 3.56.0×1012/L HGB ≤1.5 110180g/L PLT ≤4.0 150500×109/L MCV ≤0.5 80110fL Sample Volume Twig blood: 20μl Whole Blood: 13μl Sample In store 20,000 samples in store Dilution Ratio WBC/HGB: 1:500 RBC/PLT: 1:50000 Screen 8’’ Touch LCD Screen Interfaces RS232 joint, USB, PS2, Parallel port Test Speed 60 samples/hours Continuous Work Time>8h

    more..
Filter by Locality
top