Medical Ventilator Machine Dealers in Ambala

(11 products available)
  • LP6 Ventilator

    LP6 Ventilator

    Get Price Quote

    • Front Panel Input: Patient Pressure: Port for connection to proximal pressure line of  patient circuit
    • Front Panel Output: Patient Air: 22 mm x 15 mm tube for connection to bacteria filter Exhalation Valve: Port for connection to exhalation valve  of patient circuit
    • Indicators, Normal Events : Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can  also display battery charge and machine hrs of operation Breathing Effort: Green LED activated by adequate patient breathing effort Power: LEDs indicate operating power so
    • Audible Alarms: Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure,  Setting Error, Power Switchover  Steady Tone: Loss of microprocessor control Reminder Tone: Every 5 mins when powered by Internal Battery,  each time accessory printer generates
    • Rear Panel Controls: AC Circuit Breaker: Internal to AC power switch (1 for ON; 0 for OFF)
    • Rear Panel Inputs: Inlet Filter: Intake for patient air; screw off cap for filter change External Battery: Connection for 12  VDC battery Communication Port: Calibration information  during service procedure 
    more..
    JaincoLab
    Ambala
    0.0 View Profile
  • Endotracheal Tube

    Endotracheal Tube

    Get Price Quote

    Endotracheal Tube made from special non-toxic, clear, thermo sensitive siliconised PVC material. Radio opaque line to assess exact location of tube. All Endotracheal Tube is fitted with 15mm standard connector and pilot balloon with integral one-way valve. Size of Endotracheal Tube clearly marked on the pilot balloon. Smooth tip aids atraumatic intubation. E.T.O Sterlized and Pyrogen free.

    more..
  • Best Deals from Medical Ventilators

  • BPAP System

    BPAP System

    Get Price Quote

    This sort of machine has bi-level positive airway pressure with multiple modes. This machine does not work as a life support; instead it helps those suffering from sleep apnoea or hypopnoea syndrome. It is a disorder where the patient has breathing difficulty while sleeping. It has certain feature:- It works in CPAP, T, S/T and modes. It has a large LCD display which help to see statistical data properly. The wave form of breathing and pressure can be displayed in real time successfully by this machine. It has the advantage of being fitted with alarms to ward off danger to the patient. MULTI-PARAMETER PATIENT MONITOR- It has a high resolution monitor. ECG, SPO2, NIBP, RESP, 2-TEMP, PR. It is lightweight and portable. It has built-in chargeable lithium battery. It has 72 alarm events to recall past parameters. Arrhythmia analysis and S-T segment analysis. It has 500 NIBP data storage and recall facility. Data and waveforms colour can be adjusted. It is capable of 32 seconds full disclosure waveform review. It can give 72 hours of graphic and tabular trends of all parameters.

    more..
  • Endotracheal Tube

    Endotracheal Tube

    Get Price Quote

    Endotracheal Tube made of class A medical grade plastic sterilizable and autoclavable material presented in set of different sizes for different patient of different age group. Endotracheal Tube is available in cuffed or uncuffed  

    more..
  • Auto CPAP

    Auto CPAP

    Get Price Quote

    • Weight: 1.6 kg ,<2.4 kg
    • Modal: ARR SU-31
    • Dimensions: 220 19401120mm / 313 194 112mm
    • temperature: 5 - 40-C -20 to 55-C
    more..
    ARR Exim
    Ambala
    0.0 View Profile
  • Ventilator

    Ventilator

    Get Price Quote

    VENTILATOR ITEM CODE: OTE-07 Power Line 220 VAC range (220-240 VAC), 0.5 Ampere, 50/60 Hz., external voltage selector switch. Gauge: Use 3-conductor harmonized cord only; up to 49′ use 18 gauge cord; up to 99′, use 16 gauge cord; up to 200′, use 14 gauge cord. External Battery: 12 VDC, 5 Amperes. Approximately 20 hrs. operation with 75-80 Amp-hour 12 VDC deep-cycle, gel-cell battery. Approximately 10 hrs operation with 35-40 Amp-hour 12 VDC deep-cycle, gel-cell battery. Internal Battery: Approximately 1 hour operation. Type: Volume ventilator. Motor Brushless induction. Pump: Piston, 100 to 2200 ml tidal volume capability. Front Panel Controls: Alarm Silence/Reset: Push button to silence alarms during events or reset after events; used with Battery Test button to read machine operating hours on Patient Pressure meter Battery Test: Push button to show battery charge level on the lower window of Patient Pressure meter. Mode: Rotary switches to set ventilator operating mode: Standby, Assist/Control, SIMV, or Pressure Cycle. Low Alarm: Rotary switch to set limit for Low Pressure alarm: 2 to 32 cmH2O/hPa in increments of 2 cmH2O/hPa High Alarm Limit: Rotary switch to set limit for High Pressure alarm {Assist/Control, SIMV modes} or limit for Pressure Cycle mode: 15 to 90 cmH2O/hPa in increments of 5 cmH2O/hPa Volume: Push-to-turn knob to set volume: continuously adjustable from 100 to 2200 ml. Breath Rate: Rotary switch to set breathing rate: 120 BPM in increments of 1 BPM and 2238 BPM in increments of 2 BPM. Inspiratory Time: Rotary switch to set time for delivery of set volume: 0.5 to 1.0 sec. in increments of 0.1 sec.; 1.2 sec.; and 1.5 to 5.5 sec. in increments of 0.5 sec. Breathing Effort: Push-to-turn knob to set pressure level for detecting breathing effort; continuously adjustable from -10 to +10 cmH2O/hPa Pressure Limit (LP10 Only): Locking knob sets pressure limit level from 15 to 50 cmH2O/hPa or closes off the pressure limit feature. Input Patient Pressure: Port for connection to the proximal pressure line of the patient circuit. Outputs Patient Air: 22 mm tube for connection to the bacteria filter. Exhalation Valve: Port for connection to the exhalation valve of the patient circuit. Indicators Normal Events Patient Pressure Meter: Displays patient pressure, -10 to +100 cmH2O/hPa; also displays battery charge and machine hours of operation when appropriate buttons are pressed. Breathing Effort: Green LED activated by adequate patient breathing effort. Power: LEDs indicate operating power source: green AC Pwr/Batt Charge, amber External Battery, flashing amber Internal Battery. Alarms: Flashing red LEDs: Low pressure /Apnea, Low Power, High Pressure, Setting Error, Power Switchover. Audible Alarms Pulsating Tone: Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover. Steady Tone: Loss of microprocessor control. Reminder Tone: Every five minutes when powered by Internal battery, each time accessory printer generates a report. Rear Panel Controls AC Circuit Breaker Internal to the AC Power Switch (1 for ON; 0 for OFF), 1 Ampere Inputs Inlet Filter: Intake for patient air. Screw off cap for filter change. External Battery: Connection for 12 VDC battery. Communications Port Calibration information during service procedure. Outputs Vent: Cooling vent for internal ventilator components Remote Alarm Connection for optional alarm accessories. Communications Port Connector for optional printer

    more..
  • Plain Endotracheal Tube

    Get Price Quote

    • Sizes: 2.0 mm to 5.0 mm Bore with 0.5 mm Stage.

    Our company offers Plain Endotracheal Tube for our esteemed global customers. These highly appreciated Plain Endotracheal Tubes are manufactured with the best quality thermo-sensitive material. Our range of Plain Endotracheal Tubes are highly demanded for its radio opaque line, 15mm connector at proximal end, peelable blister packing and intelligent design that conforms to the contour of the body’s temperature. These high quality Plain Endotracheal Tubes are used in a number of medical procedures. We offer these Plain Endotracheal Tubes in 2.0mm to 5 mm sizes at highly affordable prices in boxes of 10 pieces each. Features: Manufactured from thermosensitive material readily conforming to body contours at body temperature. Nasoral tip suitable for nasal/oral intubation. Radio-opaque line throughout the length to facilitate the exact location of the tube. Proximal end is fitted with standard 15 mm connector. Sterile individually packed in peelable blister pack. Box of 10/Master box of 100.

    more..
  • Ventilators

    Get Price Quote

    Ventilators, bacteria filters, Ecg Machine, HME Filters

    more..
  • Air Compressor Ventilators

    Get Price Quote

    Air Compressor Ventilators, Agilent 1100 HPLC System, G.M.Counter

    more..
  • Roof Ventilator

    Get Price Quote

    Ac Duct, bus components

    more..
  • Roof Ventilators

    Get Price Quote

    Bus Body Parts, sun visor, plastic locks, Plastic Handle, plastic brackets

    more..