portable cable fault locator
We are offering portable cable fault locator. Technical specifications operating time : 8 hrs continous without backlight maximum range : for open and short faults:5 kms display : 240 * 128 dot matrix liquid crystal accuracy : for open and short faults : +- 1 % serial port : rs-232 charging source : 15 v 1 amp external adaptor battery : 12 v ni-mh rechargable battery applications measure open and short faults measure low insulation faults
...morelow insulation fault locator
We are offering low insulation fault locator. Description digital cable fault locator model 5289 is a high resistance fault locator to mainly locate low insulation faults & contact or clear open faults. Its simple design, ease of operation, very light weight makes it an ideal test for even an inexperienced person to locate faults. Specifications mechanical dimensions: 245l * 158w *199h construction : powder coated ms cabinet electrical power source : (8) 1.2 vaa cable range : 15kms features direct distance to fault reading in metres portable (battery mains operator) < 2.5 kv accuracy + 0.5% locates low insulation faults upto 2m ohm simple operation
...moredigital cable fault locator
We are offering digital cable fault locator. Technical specifications operating time : 8 hrs continous without backlight maximum range : for open and short faults:5 kms : for low insulations faults:15kms display : 240 * 128 dot matrix liquid crystal testable low insulation resistance : 2 me accuracy : for open and short faults : +- 1 % : for low insulation faults :+- 0.5 % serial port : rs-232 charging source : 15 v 1 amp external adaptor battery : 12 v ni-mh rechargable battery applications measure open and short faults measure low insulation faults measure insulation resistance measure foreign potential
...morecable tester model 5199
We are offering cable tester model 5199. Description model 5199 works on a proven "pulse reflection technique" & can detect most common faults quickly. It transmits a pulse of controlled pulse width & amplitude along the pair under test. The pulse travels with a fixed velocity & propagation which depends on the dielectric material surrounding the conducter - (pvc, jelly, paper etc.) whenever there is a change of characteristic impedence, a part of pulse energy reflects back to the source & both inerdent & reflected pulse are displayed on crt. The distance to fault is computed & displayed on 4 12 digit led display. Specification range : 5 kms10kms accuracy : + 1 % display : cathode ray tube : 95 mm rectangular 7-segment, 4 12 digit led
...morecable route tracers
cable fault locators
low insulation fault locators
microelectronics measurement