Numerical over Current Relay with Communication JNC 068 C
Get Price Quote
Features Programmable for 1A / 5A relay rating 3 OC + 1 EF + 1 SEF/REF Choice of 6 IDMT curves and definite time Trip test facility History of 6 latest faults along with settings Self supervision facility MODBUS open protocol over RS – 485 port MODBUS protocol over RS – 232 port Draw out facility with inbuilt CT shorting Standard dimension – 144mm x 144mm Principle of Operation: The relay measures the line current from each of the line CTs and if the current exceeds the set threshold, then relay extends a trip signal after an operating time. The relay's “operating time” is determined by selecting “definite time” or one of the six “inverse time” characteristics. Input to sensitive earth fault protection can be connected in two ways. First one the residual current derived from three phase current transformers, and second is low output core balance current transformer can be connected. Input to restricted earth fault protection will be derived from neutral CT output with external stabilizing resistor. Phase over current, Earth fault, Sensitive earth fault/Restricted earth fault protections* features can be made active or inhibit independently.
Magnetic Latching Relay
Get Price Quote
Magnetic latching relay, Ortecs specializes and makes available custom & standard relays for the vivid industries, acknowledged for the advanced technological design, durability and high performance, our Electronic Components are high in demand in both national and international markets. SIGNAL RELAY • GENERAL POWER RELAY • AUTOMOTIVE RELAY • MAGNETIC LATCHING RELAYE
Best Deals from Current Relay
Numerical over Current Relay
Get Price Quote
Being a client-centric organization, we are engaged in manufacturing, supplying, exporting and trading Numerical Over Current Relay. Based Over Current Relay (OCR) with Earth Fault Relay (EFR), these relays are extensively used for selective over current. Apart from this, applicable in substations and industrial networks, these relays are widely used for earth fault protection of radial feeders in impedance earthed power systems. Features: Definite time curve for both Phase & Earth along with optional user defined curve Low AC burden Reliable auxiliary supply of wide range input of 18-85 or 85-275 volts AC or DC Non-Volatile memory for data retention and retrieval in the event of power failure Unique combination of 505150N51N in a single gadget Consistent repeat accuracy High Drop-offPick-up ratio Poly carbonate front cover with external reset switch Specifications: Accuracy Of Operating Time: For Idmt,Definite Time and Instantaneous ±5%, ±3% and Less than 2 Cycles Relay Rated Current (In) 1A or 5A user selectable Frequency 50 Hz or 60 Hz Auxiliary Voltage Range 85V-275V ACDC, 21-130V DC Pick-Up 103% Drop-Off 97% Ac Burden < 0.4VA for 5A and < 0.2VA for 1A Dc Burden < 5W during non operated condition and < 7W during operated condition Dimensions 151 x181x195 mm (WxHxD Mounting Flush Panel Cut-Out 151 x 157 mm + 0.1mm Contact Rating AC: 250 V @ 30 AMP and DC: 24 V @ 30 AMPS, 2 CO or 3 CO Operating Temperature 5 to +55°C
Numerical Draw-out 1 Over Current
Get Price Quote
The micro-controller continuously monitors the magnitude of the phase current andthe neutral current .whenever the phase current or the earth current magnitude exceeds thepresent value corresponding line / earth element will pick up and relay will trip after timeinterval calculated by the selected IDMT curves. Whenever the fault level exceeds theselected high set range, the relay will trip for high set, ignoring the selected IDMT curves. Thetimer logic is processed and after comparison with set time schedules, tripping signals areissued accordingly. There are two output relays , each output relay has two change overcontacts either for alarm or tripping. The output relays are programmable.The relay rating (In) is field selectable either 1A or 5A. The relay has RS 485 com port which canbe used with modbus protocol for communication purposes. Specification Trips for default/previously selected curve if the fault occurs during settings of the relay Membrane key pad for easy operation, dust proof front panel Enabling /Disabling o f High-Set RS-485 communication port with modbus protocol Relay test facility with relay trip & without relay trip Separate heavy duly output contacts provided f or time delayed phase fault with high-set and time delayed Earth Fault with high-set Consistent repeat accuracy Poly carbonate front cover with external reset switch
Short Circuit Protection Relay
Get Price Quote
Short Circuit Protection Relay are applied in cases where only protection against short circuit currents is required. It has featues like LED indication of fault condition, Timer-controlled tripping and LED indication for activated relay.
Powered Overcurrent Protection Relay
Get Price Quote
MJT 314B (Self powered numerical over current protection) & MJT 314C (Self powered with series trip numerical over current protection) relay combines the power and flexibility of microprocessor technology with decades of experience in the field of protection. A wide range of protection elements and characteristics are supplemented by advance features such as metering, fault recorder and communication. MJT 314 (B&C) offers inverse time and definite time over current protection for phase fault and earth fault with communication Application Distribution Feeders Transmission lines AC machines Capacitor banks Transformers Used in Compact MV Switch boards with CB Where Auxiliary Voltage is not available or guaranteed
Numerical Directional over Current Relay
Get Price Quote
We are offering numerical directional over current relay. Features programmable characteristic angle programmable operating characteristics high speed directional control low burden trip test facility.
Numerical Directional Overcurrent Protection Relay
Get Price Quote
We offer numerical directional overcurrent protection relay. Mit121131 is micro-controller based numerical true rms single pole directional over-current protection with voltage polarization, and the relay will operate depending on the direction of fault current and relay setting. versions: mit 121 - single pole directional over-current protection mit 131 - single pole directional over-current protection with dc transient free high set application distribution feeders transmission lines solidly or resistance grounded systems
Current Sensing Relay
Get Price Quote
Circulating Current Relay
Get Price Quote
The circulating current relay IRXm is mainly used for high-speed restricted earth fault protection of generators and transformer windings. For the selective detection of faults, current transformers in summation connection are employed with an external stabilizing resistor for high impedance method of measurement. The relay is provided with a band-pass filter which suppresses harmonics and DC components of the input current. The relay is suitable for current transformers with secondary rating of both 1A and 5A.
Numerical over Current Relay
Get Price Quote
Numerical over Current Relay, Static Relays, Medium Voltage Switchgears
Single Phase over Current Relay
Get Price Quote
Single Phase over Current Relay, Alternator Voltage Regulators
Current Relay
Get Price Quote
Current Relay, Headlight Relay, Changeover Relay, General Purpose Relay
Current Relays
Get Price Quote
Current Relays, Numerical Relays, Other Products
Short Circuit Protected SSR
Get Price Quote
Short Circuit Protected SSR, AC Input Module, Single Channel Relay