Water Monitors and Nozzles
Water Monitor: They are manually operated fixed devices that are used to direct the high pressure water to the region under fire. Nozzle: These are manually operated hand-held devices that are used to direct the high-pressure water to the region under fire. We deal with Nozzles made of Gun Metal, Stainless Steel & Aluminum.
...moreWater Based Fire Extinguishers
Water was the only extinguishing agent when there was no tech in this field. The Pioneer of Fire Fighting is the water based fire extinguishers. This range is exclusive to only the A class of fire. Water is released from the extinguisher with pressure spreading over the fire and extinguishing it. Water extinguishes the visible fire as well the fire that is igniting deep inside the flammable object which gradually raises the temperature causing more havoc than one can imagine. Hence this primary range offers sufficient protection from such fires. The higher variants of this type are provided with a trolley for easy portability. It is manufactured in cartridge type & stored pressure type.
...moreSwitches and Valves
Switches: These automatic devices are responsible for the hassle free operation of the hydrant systems, when there is a pressure drop in the pipeline; they automatically switch on the pumps to regulate the pressure to the set limit. Valves: Valves regulate the flow of water through the pipeline, they are of many types depending on their design & function. Some of them are the Hydrant Valves, Butterfly Valves, Non-Return Valves, Ball Valves, and Foot Valves etc.
...moresprinkler systems
These automatic systems are a sub part of the hydrant systems. A sprinkler pipe line runs through the building with a separate sprinkler pump. The main functional device is the sprinkler that has a fluid contained in a glass case which expands when the temperature exceeds a prescribed limit causing the glass case to break making way for the high pressure water to flow through the sprinkler blades and sprinkle water in its radius. The following are the types of sprinkler based on their location. Pendant Sprinklers: They are fixed below the sprinkler pipe line as a pendant. Upright Sprinklers: They are fixed above the sprinkler pipe line in an upright position Horizontal Sidewall Sprinkler – They are fixed horizontally to the sprinkler pipe line.
...moreAccess Control and Biometrics Systems
These systems provide complete protection against intruders and allow only authorized personnel to get through. We supply & install the best systems that are accessed with either magnetic cards or chips. To make it more secure we also offer biometric systems that can only be accessed either with your fingerprint or your retina’s.
...morefire pumps
Fire Pumps: The backbone of the entire system, these devices are responsible for pumping water with high pressure through the pipeline so that they can cover a larger area. Diesel Engines: During fire, electricity is cut off. Therefore the diesel engines provide the required power for the pumps to operate.
...morepowder based fire extinguishers
When there is a fire around you, the environment is chaotic. You may hardly get any time to think, and in such cases when you pick an extinguisher not suitable for the particular class of fire, it can prove fatal. That is when this particular range comes in to play.The ABC Powder Based Fire Extinguisher is an all-rounder and can be used on almost all classes of fire (Class A, B, C & electrically caused fire). It is a pressurized cylinder consisting of Mono-Ammonium Phosphate Powder (MAP) as the main extinguishing agent. On usage, it forms a blanket over the fire due to the closely packed particles in the powder disabling or cutting off the oxygen supply from the environment. This extinguishes the fire and brings down the temperature considerably.Depending on the percentage of MAP in the Fire Extinguisher, this category is sub-divided in to two categories: MAP 50 (M
...moreModular Fire Extinguishers
This special range requires no human support for its functioning, commonly known as the automatic or modular fire extinguisher, they are used in areas where human movement is very limited and fire at its initial stages cannot be detected. This ceiling mounted fire extinguisher senses the rise in temperature and floods out the content in its entire radius extinguishing the fire. It can either contain the ABC Powder or the Clean Agent depending on the client’s requirements. Classes Covered: ‘A’,‘B’, ‘C’ & ‘Electrical’ Capacities Available: 5 KG ; 10 KG
...moreFire Alarm and Detection Systems
Detecting a fire and alarming the environment about it has become very crucial in today’s generation. Human Monitoring is not possible at all times, hence we require a smart and intelligent system that can detect and alarm people that there is a fire. This is where the Fire Alarm & Detection Systems come in to play. Due to the growth in technology, today we can even detect fire in places not visible directly. Guard Fire Services deals with the designing, installation, programming, servicing and maintenance of the fire alarm systems. Control Panel The brain of the Fire Alarm System, it controls, monitors and displays the status of all the devices in the entire area. With the help of the control panel we can know exactly where the fire has started. The control panel is of 3 types: Conventional – It is the initial tech in the field of fire alarm, a reliable system that can give orders to its limited devices to alarm the vicinity about fire in a particular area or zone. Depending on the area, the capacity of the panel is decided. Commonly used conventional panels are the 2 zone, 4 zone & 8 zone conventional panels. Analog Addressable – It is the current tech in the field of fire alarm, it is capable of handling a huge area as its each loop can connect up to 200 devices. It is a highly sophisticated system that can alarm the authorities of where exactly the fire has occurred.
...moreElectronics Hooters/Strobes/Sounders
Hooters: They produce a loud hooting noise on receiving signal from the panel in case of fire. The intensity of sound is high enough to alert the entire area it is meant to cover. Strobes: They are used in areas that restrict noise, they produce a large flash which alerts the surrounding of a fire. These are also helpful for the deaf as they cannot hear the loud noise of a hooter. It also comes in a combination of horn cum strobe, which serves both the purposes. Sounders: They are fixed to the ceilings for alerting a small area in case of a fire emergency.
...moreDetectors (Smoke/Heat)
These are intelligent devices that are used to detect fires or smokes arising from a fire. These are one of the automatic devices that require no human support. Their function is to provide primary input signal to the panel, these are of various types depending on what they sense. Smoke Detectors: Fire at its initial state is just smoke and fumes which when detected as early as possible is helpful in subsiding it. Smoke Detectors detect arising smoke and send input signal to the panel that there is a fire. Heat Detectors: These devices are provided with thermistors inside that detect sudden increase in temperature of the surrounding area. On sensing this it sends input signal to the panel that there is a fire.
...moreCLEAN AGENT BASED FIRE EXTINGUISHERS
The most eco-friendly extinguisher available out there are the Clean Agent Based Fire Extinguishers, they contain a special chemical that evaporates after usage leaving behind zero residue suiting best for sensitive equipment and areas like computers & server rooms that would undergo malfunction if powder based fire extinguishers were used. This special range can extinguish all classes of fire and can be used under any circumstance. It is indeed the most effective all-rounder. Its working action is similar to that of any other fire extinguisher.