Direct On Line Motor Starters - (pe-1 )
1,500 Per piece
100 piece (MOQ)
auto turned components
Get Price Quote
Our products are intricately machined by high precision machine with experienced engineers who make these products accurate in dimensions and high in durability.These components are manufactured on very high precise sliding head automats and traubs machines and regular quality checks are carried out at proper intervals Some of its features are:* Durability* Reliability* Consistency
Best Deals from Instrumentation Equipment
J Type Thermocouple Sensor
750 Per Piece
Electric Power Distribution Panels
Get Price Quote
With its client oriented service for past several years, our company has gained a renowned name and fame in the market for the manufacture and supply of a wide array of Electric Power Distribution Panels. These Electric Power Distribution Panels are one of the most required and necessary equipment for industrial purposes where there are provisions of complex electrical circuits and costly machinery. Electric Power Distribution Panels are generally connected to the main power source and are meant to control even and regulated power dissipation in the circuits. Electric Power Distribution Panels are available at a very convenient and exiting range of prices at our company.Features Cost effective Reliable work performance Smooth and hassle free functioning Equipped with easy controlling switches and regulators Provided with LED indicators and meters Robust and durable construction
repeater panel
Get Price Quote
Mahaveer Fire Safety is trusted by clients for supplying Fire Alarm Repeater Panel that is sophisticatedly designed by the experts. To cater to the diverse requirements of the clients, we supply, the Fire Alarm Repeater Panel in the market in varied specifications. The efficient performance of these Repeater Panels has earned us a huge list of clients in nationwide markets. MAIN FEATURES � Built in Power supply � Built in Buzzer - Audio Alarm � Mute Switch - To silence Audio Alarm � User friendly display - Back lit LCD (Liquid Crystal Display 4x20)80 Characters � LCD gives - Zone Number, Floor Number And Block details where exactly Fire is occurred. TECHNICAL SPECIFICATION Mains Input Voltage : 230 V A.C, 50Hz +/- 10V Secondary Voltage : 5V.DC Normal current consumption : � 50mA @ 230V And � 100mA @ 5V D.C Maximum current consumption : � 200mA @ 230V And � 500mA @ 5V Enclosure : CRCA Fabricated Wall mounting type Dimensions : 300(H) x340(L) x100(D) mm
single phase control panel
4,500 - 4,800 Per Per Unit
10 Long Ton (MOQ)
Electrical Panel
Get Price Quote
Automatic Mains Failure Panel
Get Price Quote
AMF panel and generator packages are designed to provide emergency power during mains supply failure. During operation, the control panel of the AMF monitors the mains entering the building. If a mains failure occurs, the panel will disconnect the mains from the load, the generator is started and its output connected to the load. (The load being appliances, lights, etc in use within the house/office/factory at the time of mains failure). The generator continues to supply the building until the mains supply returns. The generator then automatically disconnects, stops and the mains is re-connected to the load. The AMF panel reverts to the standby mode ready to respond in case of another mains failure. Operation With the generator in 'Auto' mode, the incoming main is monitored continuously. If the mains voltage falls outside the preset limits, a 'mains failure' has occurred and the process of starting the generator set is initiated. Once the mains failure is recognised, the contacts are released to disconnect the load from the mains. The 'mains available' and 'mains on load' lamps extinguish. There is a pre-set and adjustable time delay before the generator is started. This avoids unnecessary starting of the generator when very short duration mains breaks occur e.g. 2 or 3 second breaks due to lightning strikes. After the delay, the engine fuel solenoid / ignition system is energised. A pre-heat period begins for generators fitted with indirect injection diesel engines. The choke is operated on petrol-engined sets. The starter motor relay energises and the engine is cranked for a pre-set period (typically 10 seconds). If the engine fires up and the speed increases through the 'crank-cut' threshold, then the starter motor is dis-engaged. Alternatively, if the engine does not start during the first crank period then the starter de-energises for an equal rest period before energising for another attempt. If the engine has not started after the last 'crank' period, then the engine fuel solenoid / ignition is de-energised and the generator is deemed to have failed to start and the appropriate annunciator is illuminated. Assuming that the generator has started during one of the attempts, the alternator output is checked to ensure that it is within specification. If so, then the generator contactor is energised and the load is supplied from the generator. In normal circumstances, the period from mains failure occurring to generator supply being connected is about 20 seconds. During generator operation, the engine oil pressure and temperatures are monitored and should an abnormality occur, the generator will immediately be shutdown and the appropriate annunciator illuminated. When the mains supply returns, the mains available lamp is illuminated within specified limits. The main is then monitored for a pre-set time to ensure that the supply is stable. The generator contactor is then de-energised and the mains contactor energised so that the mains supply is restored to the load. The 'alternator available' and 'alternator on-load' lamps extinguish and 'mains on load' lamp is illuminated. A short break in approximately 1 second occurs whilst the changeover is complete. The generator is 'run-on' for a cooling down period (adjustable up to 30 minutes) before the fuel solenoid / ignition system is de-energised and the engine stops. The operational cycle is then complete and the generator returns to a standby condition. During this time the starter battery is maintained in a charged condition by a 'trickle' charger supplied from the mains.
solar power panels
Get Price Quote
Wè provide high efficiency off grid solar power panelsfor your house, industry. need based solutions are executed based on your requirements. n choice. Additional Information : Minimum Order Quantity: 1 Kilowatt
WPC Board
80 Per Square Feet
10 Piece(s) (MOQ)
Fire Damper Control Panel
700 - 750 Per No
10 Piece (MOQ)
Fire Alarm Panel Board
5,200 - 22,000 Per Piece
1 Piece (MOQ)
Automobile Components
Get Price Quote
We are engaged in manufacturing, exporting and supplying a range of motor housing that is fabricated by our experienced engineers and talented technicians. Forged from superior quality raw materials, our products are highly durable and resistant to corrosion. Owing to these properties, these motor housing are widely used as the upper end for motor in submersible pumps. Available in various designs and sizes, our motor housing can be further customized according to the requirements and specifications of our esteemed customers.
Motor Starters
800 - 925 Per piece
20 pieces (MOQ)
Agricultural and industrial products
Control Panels
5,000 Per pcs
1 pieces (MOQ)
Control panels: PLC Based, relay &contactor logic panels, VFD / Varable Frequency Drive panels, Direct online panels.
Rexroth Servo Drive
Get Price Quote
Home Automation System
Get Price Quote
We build smart home with automation, combined with latest amenities and standard safety house practices.
direct on line motor starter
Get Price Quote
Offers direct on line motor starter. Type: gl - 2 gl - 3 range: 10 to 30 hp gl - 2 type " ganga" d.o.l motor starters have robust construction and offers smooth and reliable performance. They are designed to meet the most stringent requirements of both industrial and agricultural fields. These motor starters comply with requirements of is standards. Thermal overload relay the gl - 2 relay consists of bimetallic elements, which are individually calibrated & tested for precise operation. An extra 'no' contact is provided to give clear warning when overloading of motor occurs. Once they relay has tripped due to overload the starter cannot be reset until the bimetal elements have cooled down sufficiently. Contact system the silver alloy tipped contacts ensure long electrical life & are bounce free when closed. They can be easily accessed for inspection or replacement. Magnet system & coil laminated 'e' stampings are used for construction and are designed for low loss. Shading rings are provided to reduce hum & chatter. Coils are layer wound and are designed for long life. They consume less power & can withstand wide voltage fluctuations particularly in rural areas.
Preventor DOL Motor Starter
Get Price Quote
Based on India most popular design of motor starter, the new DOL Motor Starter Type LK1 + SPP, is India’s only DOL starter with inbuilt current sensing single phasing protection that ensures protection during starting as well as running. There is no additional wiring required as the preventor is prec-connected.
Main Power Distribution Panel
Get Price Quote
As a quality oriented organization, we, Vajra Controls in Bangalore are engaged in manufacturing and supplying a broad array of Main Power Distribution Panel. The offered power distribution panel is widely used at the residential, commercial and industrial places, for enclosing the electrical circuitry and wiring. We offer these panels in various dimensions of sizes and width and also provide customization according to the specifications provided by the customers.