(178 products available)
  • DOL Motor Starter

    DOL Motor Starter

    750 Per Piece

    20 Piece(s) (MOQ)

    • Type: Dol Starter
    • Application: Electrical Equipments
    • Certification: AN ISO CERTIFIED COMPANY
    • Color: Grey
    • Voltage: 220V, 380V, 440V
    • Automatic Grade: Manual
    • Driven Type: Electric
    • Phase: Three Phase
    • Current Type: AC

    with sincerity and hard work of our professionals, we have carved a niche for ourselves in this domain by offering premium quality gamut of dol motor starter..

    more..
  • Ultrasonic Level Transmitter

    Ultrasonic Level Transmitter

    Get Price Quote

    • Temperature: 0 to 65 deg C
    • Electronics Housing: Stainless Steel or die cast aluminium, flame proof
    • Applications: Liquids including hazardous but non-corrosive medium
    • Input Supply: 24V DC
    • Analog output (Programmable): 4 – 20mA 20 – 4 mA 0 – 10 V DC 10 – 0 V DC
    • Mode: Distance OR height measurement
    • “ Display ”: 8 x 2 alphanumeric displya, “ 7 segment LED ”
    • Communcation: RS 485 – Modbus
    • Measuring range: 5mtr, 10mtr 0.5mtr, 1 mtr, 3.5 mtr
    • Resolution: 1mm, 5mm or 10mm depending on models
    • Accuracy: 0.5% of FSD
    • Updation time: 150 mS max
    • Minimum distance: 40mm to 300mm depending on range
    • Display Filter: None / Low / Medium / High
    • Temperature compensation: Inbuilt
    • Voltage Variations: Internal calibration and automatic compensation
    • Process connections: ½” BSP, 1 ½” BSP
    • Electrical connections: PG 9 one gland, 2 numbers
    • Sensor face: Anodised aluminium
    • Sensor body: PVC
    more..
  • Best Deals from Instrumentation Equipment

  • DOL Submersible Pump Panel MaK-1 Three Phase (Gold) (Compact)

    DOL Submersible Pump Panel MaK-1 Three Phase (Gold) (Compact)

    Get Price Quote

    • Power:: 2, 3, 5, 7.5 & 10 H.P
    • Phase:: Three Phase
    • Voltage:: 440 V

    MAGNUM Three Phase  Pump Control Panel Goldis a powerful controlling device for your submersible pump made with heavy duty components, it switches & protects your pump from hazards caused due to over-current.   Salient Features: Three Phase Pump Control Panel powder coated MS enclosure for corrosion resistance & sturdiness. Rugged MaK-1 Contactor with wide voltage band (140-220V). Fitted with MaK-1 type relay for reliable overload protection. Fitted with toroidal type current sensing preventer which can be used to protect the motor against single phasing. Fitted with a voltage selector rotary switch to reading phase to phase voltage between all phases. Easy & Quick mounting. Ergonomic design with aesthetic looks. No screw protruding from the panel back. Hence additional safety from water, dust, corrosion and electric shock.

    more..
  • APFC Panel

    APFC Panel

    500,000 Per Set

    Inphase apfc series comes in various range depending on customer requirement. Inphase uses advanced micro-processor for power factor control and does complete site analysis for recommending the product which in turn is customer oriented when it comes in budget.

    more..
  • Fluorescent Starter

    Fluorescent Starter

    Get Price Quote

    10000 Piece(s) (MOQ)

    • Brand Name: Ridhi

    We are one of the manufactures of fluorscent starter for tube light.

    more..
  • Automatic Power Factor Panel

    Automatic Power Factor Panel

    Get Price Quote

    • Feature: Advanced microprocessor for Power factor Control.

    APFC provides compensation for reactive power based on the variations in load conditions to maintain the target power factor. In APFC switching the capacitor is significant as it helps to retain the power factor, the switching is controlled by a Power Factor Controller device that uses the CT feedback to determine the kvar required at any instant. The Power Factor Controller also provides information on the network characteristics such as Active, reactive power, Voltage, power factor for the user to understand. The system generally comprises of Power Capacitors, Controller, firing circuits.The switching system for this depends on the type of compensation.

    more..
  • industrial rubber components

    industrial rubber components

    Get Price Quote

    • Size: 0-10cm, 10-20cm, 30-40cm
    • Type: Rubber Components
    • Material: Rubber
    • Thickness: 0-20mm, 20-40mm
    • Application: Automobile Use
    • Color: Black
    • Feature: Anti Sealant, Durable
    • Technics: Molding

    Our Industrial Rubber Components are highly reliable and durable. These components are dimensionally very accurate and have close manufacturing tolerances. We offer rubber components that are easy to use and are high in performance. Our rubber components are also very sturdy, flexible and resistant to chemical, corrosion and high temperature. Our rubber components are available in various shapes and sizes. We offer these rubber components at very reasonable prices.

    more..
  • Automatic Mains Failure Panel

    Automatic Mains Failure Panel

    Get Price Quote

      AMF panel and generator packages are designed to provide emergency power during mains supply failure. During operation, the control panel of the AMF monitors the mains entering the building. If a mains failure occurs, the panel will disconnect the mains from the load, the generator is started and its output connected to the load. (The load being appliances, lights, etc in use within the house/office/factory at the time of mains failure). The generator continues to supply the building until the mains supply returns. The generator then automatically disconnects, stops and the mains is re-connected to the load. The AMF panel reverts to the standby mode ready to respond in case of another mains failure. Operation With the generator in 'Auto' mode, the incoming main is monitored continuously. If the mains voltage falls outside the preset limits, a 'mains failure' has occurred and the process of starting the generator set is initiated. Once the mains failure is recognised, the contacts are released to disconnect the load from the mains. The 'mains available' and 'mains on load' lamps extinguish. There is a pre-set and adjustable time delay before the generator is started. This avoids unnecessary starting of the generator when very short duration mains breaks occur e.g. 2 or 3 second breaks due to lightning strikes. After the delay, the engine fuel solenoid / ignition system is energised. A pre-heat period begins for generators fitted with indirect injection diesel engines. The choke is operated on petrol-engined sets. The starter motor relay energises and the engine is cranked for a pre-set period (typically 10 seconds). If the engine fires up and the speed increases through the 'crank-cut' threshold, then the starter motor is dis-engaged. Alternatively, if the engine does not start during the first crank period then the starter de-energises for an equal rest period before energising for another attempt. If the engine has not started after the last 'crank' period, then the engine fuel solenoid / ignition is de-energised and the generator is deemed to have failed to start and the appropriate annunciator is illuminated. Assuming that the generator has started during one of the attempts, the alternator output is checked to ensure that it is within specification. If so, then the generator contactor is energised and the load is supplied from the generator. In normal circumstances, the period from mains failure occurring to generator supply being connected is about 20 seconds. During generator operation, the engine oil pressure and temperatures are monitored and should an abnormality occur, the generator will immediately be shutdown and the appropriate annunciator illuminated. When the mains supply returns, the mains available lamp is illuminated within specified limits. The main is then monitored for a pre-set time to ensure that the supply is stable. The generator contactor is then de-energised and the mains contactor energised so that the mains supply is restored to the load. The 'alternator available' and 'alternator on-load' lamps extinguish and 'mains on load' lamp is illuminated. A short break in approximately 1 second occurs whilst the changeover is complete. The generator is 'run-on' for a cooling down period (adjustable up to 30 minutes) before the fuel solenoid / ignition system is de-energised and the engine stops. The operational cycle is then complete and the generator returns to a standby condition. During this time the starter battery is maintained in a charged condition by a 'trickle' charger supplied from the mains. 

    more..
  • Kissan Direct On Line Motor Starters

    Kissan Direct On Line Motor Starters

    Get Price Quote

    We bring forth an exclusive range of direct on line motor starters that is manufactured using quality components and hi-tech machines. Our array of direct on line motor starters is high on demand in the market and is developed in compliance with the varying industrial standards. These starters are known for their sturdiness and optimum efficiency. Besides, these starters can be availed at the most reasonable prices. Appreciated for : trouble-free operationsrugged constructioncorrosion resistance propertydimensional accuracyhigh tensile strength consists of : contactor : which makes and breaks the motor circuit in a starter, is subject to maximum wear, pe-1 contactors have exceptional endurance. The contact system is double break type consisting of robust bounce-free silver contacts.solenoid coil : is machine wound, taped, vaccum-impregnated and baked for tropicalisation. It undergoes rigorous impulse tests in addition to routine check for continuity and for pick-up and drop-off voltages. The coil also acts as an under voltage release, disconnecting supply to motor when the supply voltage is low thus preventing. The motor from serious damages.bimetalic contacts : tested for millions of operations without failure.thermal over load relay : has accurately calibrated bimetallic elements with ambient temperature compensator for over load protection. For more information refer to over load relays. Spares and accessories : thermal over -load relaycontactortimerspare kitoperating coilauxiliary

    more..
  • solar power panels

    solar power panels

    Get Price Quote

    Wè provide high efficiency off grid solar power panelsfor your house, industry. need based solutions are executed based on your requirements. n choice.   Additional Information : Minimum Order Quantity: 1 Kilowatt

    more..
  • Automotive Rubber Components

    Automotive Rubber Components

    Get Price Quote

    Automotive Rubber Components, Silicon Extrusion, two wheeler floor mat

    more..
  • Fire Alarm Panel Board

    Fire Alarm Panel Board

    5,200 - 22,000 Per Piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Type: Fire Alarm
    • Application: Industrial
    • Color: Red
    • Feature: Durable, Quality Assured
    more..
  • Fire Damper Control Panel

    Fire Damper Control Panel

    700 - 750 Per No

    10 Piece (MOQ)

    • Size: Multi Channels
    • Type: Control Panel Boards
    • Voltage: 220V
    • Material: Mild Steel
    • Power: 1-3kw
    • Power Source: Electric
    • Phase: Single Phase
    • Country of Origin: India
    • Warrenty: 1 Year
    • Autoamatic Grade: Semi Automatic
    • Brand Name: SiliconShelf
    • Material: MS
    more..
  • vacuum circuit breaker panel

    vacuum circuit breaker panel

    Get Price Quote

    The circuit is designed for AC DC supply including Anti Pumping contactor. The type tests conducted by us in CPRI Bangalore is as follows Lighting Impulse & Power Frequency Voltage Withstand Test (Dry) as per IS 34271997 RA IEC 62271-2003 LI 75kV (peak) & PF 28kV. Temperature Rise & Milli volt drops test on 1250A VCB as per IEC 62271-100-2003 . Short- time & peaks withstand current tests as per IEC 62271-100-2001 25 .61kA rms for 3 .07 secs and peak 69.42kA. Measurement of the resistance of the main circuit & Mechanical endurance test for 1000 operations

    more..
  • K Type Thermocouple

    K Type Thermocouple

    Get Price Quote

    We are one of the renowned thermocouple manufacturers in Bangalore of different applications and specifications. Our thermocouples are specially made under stringent quality conditions. Features: Available for all possible applications Can be made to customers specifications Types-J,K,T,E,R and resistor sensor Supplied with calibration certificates and accessories Available in Plain, Bayonet, Washer, Leaf and Ring types.

    more..
  • Plc System

    Plc System

    Get Price Quote

    Plc System, Ac Drives, Electrical Items, Power Capacitors, Power Supply

    more..
  • cement fibre board

    cement fibre board

    550 Per Piece

    • Material: Cement
    • Usage/Application: Residential
    • Color: White
    • Pattern: Plain
    • Moisture Content: 4-8 %
    more..
  • Differential Pressure Transmitter

    Differential Pressure Transmitter

    4,500 Per Piece

    1 Piece (MOQ)

    • Accuracy: +/- 0.5% @ FS.
    • Model Name/Number: DPT-5600
    • Brand: Surya Insts
    • Power: 24 VDC
    • Current Output: 4-20mA, 2-wire
    • Sampling Rate: 10 Sample/sec
    • Enclosure: ABS Plastic
    more..
  • automatic tool changer

    automatic tool changer

    550,000 Per Piece

    • Model No: MR5D
    • Weight: 550 KG
    • Magazine Speed: 0.8 sec/Tool
    • Tool Capacity: 24 T
    • Tool Diameter: 110/200mm
    more..
  • process recorder

    process recorder

    65,000 Per Piece

    • Country of Origin: Made in India
    • Usage/Application: Industrial
    • Input Phase: Single Phase
    • Input Voltage: 265 VAC
    • Material: MS
    • Frequency: 50 Hz
    more..
  • Metering Cubicle

    Metering Cubicle

    Get Price Quote

    • Short Circuit: DCCDHRT2014S0080 (20KA rms for 1 sec)
    • High Voltage: HVML2015S0659 (12/28/75KV)
    • Temperature Rise: DCCDHRT14S0080 (200 Amps)
    • IP 55: EATDHVML2014S0659 (Category 2)

    11/12kv Metering cubicle is manufactured with zero bushings i.e. the outgoing and incoming cables are provided with the bottom cable entries as per EB’s. The cubicle is divided into four chambers chambers –one for incoming, one for outgoing ,One for CT’s & PT’s and one more for energy meter. The cubicle is dust proof and pilfer resistant / non tamperable. The cubicle is available in 3Ph.4W Systems. Sealing facilities are as per EB Norms and assembled with suitable bus bars and the Cubicle is powder coated with 80-120 microns for its inner / outer texture with High Quality Process.   Application: They are used in Residential / Commercial/Large & Small Industrial Uses.

    more..
  • Semi-Automatic Control Panel

    Semi-Automatic Control Panel

    Get Price Quote

    Our company offers Semi-automatic panel for its manifold system depending on the need and customer specification. The Control panels are safe for low voltage operation and supported with audio visual alarm facility.

    more..
  • Auto Starters

    Auto Starters

    Get Price Quote

    Auto Starters, Sheet Metal Press Components

    more..
  • MCC Panel

    MCC Panel

    Get Price Quote

    Since our inception in 2013, we have been actively engaged in manufacturing and supplying a wide array of MCC Panels in Bangalore. Manufactured using qualitative raw material, these panels are also known for their reliable usage, excellent performance, diverse applications, low maintenance, resistant against corrosion etc. These panels are extensively used in many sectors and they are available in various sizes, grades and other specifications as per their needs and requirements.

    more..
  • Outdoor Motion Sensor

    Outdoor Motion Sensor

    Get Price Quote

    • Type: Wired Wireless Intruder Alarm Systems
    • Brand Name: HONEYWELL
    • Brand Name: DSC
    • Color: White
    • Operating Temperature: -40 deg.C to 70 deg.C
    • Power Source: Battery
    • Mounting Height: From 1.5 to 3
    • Frequency: 868MHz
    • Range: 12m
    • Detecting Angle: 90 degree
    • Weight G: 600g
    • Dimensions: 157 x 147 x 124
    • Battery Type: 2 x CR123 3V
    • Tamper: Back contact
    • Features: Visual alarm verification in day and night, Auto-setup for brightness and contrast via the control panel
    more..
  • Control Desk

    Get Price Quote

    Global Infotech being a well-established organization, we are presenting a wide range of Control Desk Panel. We design these Desk Panel by using contemporary machinery utilizing the premium grade necessary material. Moreover, a series of tests is done on these Desk Panel to make sure that we are offering a completely defect-free variety. These Desk Panel are presented in numerous specifications. 

    more..
  • Ac Drives

    Ac Drives

    Get Price Quote

    Category: VF,Vector and Direct Torque Control (DTC) Incoming Voltage: 200-230 VAC( +10% -15%), 380-480VAC (+10% -15%) Incoming Frequency: 5060 Hz, +-5% Power Rating: 0.5 -450HP in Vf mode and 1MW in DTC mode Braking torque: 100% upto 15HP (Built in) Ambient: 0-45 Deg C ( 0-40 Deg C with Ip40 Cover) Communication: Profibus DP, DeviceNet, CANopen, Modbus, ControlNet

    more..
  • J Type Thermocouple Sensor

    J Type Thermocouple Sensor

    750 Per Piece

    • Features: Easy installation, Corrosion free, Optimum finish
    more..
  • data instrumentation cables

    data instrumentation cables

    Get Price Quote

    Instrumentation cables are widely used in all industries in ‘process control’ equipments, and spreading towards all industrial applications for carrying , communicating signals of voice and data, interconnection of equipments and instruments in particular to those located in plants where the transducer generated signals are transmitted to panels. Clear signals are provided from electromagnetic interference, with the protection of electrical screening.

    more..
  • Control Panel

    Control Panel

    Get Price Quote

    It is a flat, vertical where control or monitoring instruments are displayed or an enclosed unit that is the part of a system that users can access, as the control unit of a system.