cooling water system
MIN � 1C38 is a specially formulated chemical for cooling water system. It is very effective where water is hard. It prevents scale & corrosion formation caused by calcium and magnesium bicarbonates in the cooling system. IT is also effective in preventing the deposition of silica, sulphates and chlorides on metal surfaces of cooling systems. Min-IC38 Cooling Water Chemical also in the case of soft water. Specifications : Color : Colorless Specific gravity : 1.35-1.45 pH : 2 � 5 Flash Point : None Odor : Mild Pungent Dosage : 30-40 ppm. However the actual dosage will be suggested by Mina service Engineers after studying the system. How To Apply : MIN � 1C38 should be applied to the tower basin at a point of maximum circulation. Tower bleed of valve should be closed to permit a retention time of four hours. Handling : Keep the container closed when not in use The product should not be swallowed Prolonged contact with skin should be avoided Avoid breathing vapor and wear face mask and rubber gloves while handling product Note : To ascertain the correct dosage, please contact Mina Services.
Country of Origin : India
Type : Water Cooling Systems
...morecooling water systems
MIN � 1C39 is a specially formulated chemical to prevent biological growth in cooling water systems. It also prevents rusting in the system. Our MIN � 1C39 is widely used in preventing and removing the growth of fungi and algae. MIN � 1C39 contains chemical to prevent algae and fungi formation in the cooling water system. It is also very effective against Iron bacterial and thus prevents rusting. Specifications : Color : Colorless Liquid Specific gravity : 1.35 � 1.45 PH : 9.60 Flash Point : None Odor : Slight Dosage Instructions : Apply initially 75 to 100 ppm of MIN � 1C39. Repeat until control is achieved. When microbiological control is evident, reduce the dosage to 50 ppm. How To Apply : MIN � 1C39 should be applied to the tower basin at a point of maximum circulation. Tower bleed of valves should be closed to permit a retention time of four hours. Handling : Keep the container closed when not in use. The product should no be swallowed and prolonged contact with skin should be avoided. Avoid breathing vapor and wear face mask and rubber gloves while handling this product. Note : To ascertain the correct dosage, please contact Mina Services.
Country of Origin : India
Type : Water Cooling Systems
Certification : CE Certified
Application : Home Use
Weight : 10-20kg20-40kg
...moreBe first to Rate
Rate ThisOpening Hours