NICU Equipments Dealers in Sahakar Nagar, Bangalore

(2 products available)
  • Infant Warmer with Fixed Baby Cradle

    Infant Warmer with Fixed Baby Cradle

    Get Price Quote

    Infant Warmer made with hi quality unique FRR (Fire Retardant Resin) design for ultimate safety from fire and electric shocks. Neokraft Radiant Warmers are full featured NICU equipment to meet Neonatal critical care requirements for new-born baby those in need of temperature maintenance Microprocessor based servo controlled temperature controller, Modes with Skin /Air and Manual Control with LCD Screen, Independent Hi temperature sensor for Hi Temp Cut off at 39 degree. German make ceramic heater with parabolic reflector to maintain uniform temperature across the mattress with swivelling source box easy to take x-ray and procedures Unit made with high quality FRR [Fire Retardant Resin] grade fibre material for extra safety from fire, electric shocks and corrosion. Newly designed oval shape baby tray with four sides collapsible clear acrylic panels. Head up & down tilting facility for baby tray. Clear acrylic base for bottom surface Phototherapy with X ray cassette compartment

    more..
  • Infant Incubator

    Infant Incubator

    1 Per Piece

    1 Piece(s) (MOQ)

    Model bjpx-3101 power supply ac220-230v50hz,1300va maximum heater output power 350w240v auxiliary power output ac220-230v50hz,3a heater instructions 0ï½�100% temperature control mode box temperature mode; infant mode box temperature control temperature range 25ï½�37â��ï¼�37ï½�39â��(leapfrogging mode) skin temperature control temperature range 34ï½�37â��37ï½�38â��ï¼�leapfrogging modeï¼� sensor temperature display range 5ï½�65â�� warm-up time(ambient temperature is generally + 22 â��)* no more than 40 minutes temperature variability* no more than 0.5â�� temperature uniformity * (the mattress is in a horizontal position) no more than 0.8â�� temperature uniformity * (the mattress is in an inclined position) no more than 1.0â�� the difference between average incubator temperature and control temperature no more than 1.0â�� skin temperature sensor accuracy â±0.2â�� humidity control the running time of the water tank is filled with distilled water after humidity below 70%rh, at least 24 hours tank capacity 1200ml humidity display range 0%rhï½�99%rh humidity control range 0%ï½�90%ï¼�adjust 1% each timeï¼� humidity control precision â±5%rh humidity display accuracy (ambient temperature 25â��, ambient humidity 45%rh + 5% rh) â±5%rh.

    more..
  • Best Deals from NICU Equipments

Filter by Locality
top