siddharth II - Linear Accelerator
15 - 20 Per cr
1 c (MOQ)
Here is Siddharth II a ring gantry based, SBRT Enabled Linear Accelerator capable of performing treatment modalities like 3DCRT, VMAT, IMRT, SBRT and SRS. The Dual KV in-gantry imaging enables the clinicians to perform the Image Guided Radiotherapy in recorded time, increasing the throughput of Hospital With the In-built beam stopper the machine can be accommodated in an existing cobalt bunker itself 6D couch guides the clinicians for couch shift corrections and maintains accuracy of treatment Wide bore ring gantry facilitates claustrophobic free environment and accommodates multiple fixtures
Type : Ring Gantry
Brand Name : Panacea Medical Technologies Pvt Ltd
Certification : CE,FDA
...moreLilac
2,000,000 Per Piece
1 Piece(s) (MOQ)
Lilac- Full Field Digital Mammography Unit with tomosynthesis is capable of performing wide angle and faster tomosynthesis ensuring lowest dose to the patient. Its available in cassette version, digital and full field digital system.
Type : Medical Equipment
Application : Medical Use
Condition : New
...moreFlat Panel Radiotherapy Simulator - IMAGIN
Imagin simulator is used for localization of treatment areas and for verification of treatment plans prior to starting treatment. Therapy simulator helps in localizing the radiation port onto target tumor location and give a quality assured radiotherapy for better treatment outcome. Imagin has advanced cbct imaging capability for accurate image acquisition and reconstruction in one gantry rotation. Salient features: asymmetric collimator: jaws moves in both in asymmetric and symmetric modes. field delineating wires: for clarity in light and radiography fields. fad: wide focus to axis distance of 80 to 120cm to cover all therapy machines. digital radiography: high resolution images with minimum dose to patient. digital fluoroscopy: fluoroscopic mode is used to view real-time image of the moving organs and foot switch control at the control console. versatile patient support: fully motorized, pit mounted iso-centric patient support couch. couch with 4 motorized motion-longitudinal, lateral, vertical and iso-centric rotation. table top with carbon fiber with radio-lucent. high frequency generator for low ripple image and high quality image with low dose to patients. Imaging unit: radiological imaging unit provides 43x43cm amorphous silicon flat panel detector to visualize anatomical structures by converting a pattern of x-radiation into a visible image through electronic amplification 2874x2840 pixel. 30 frames per sec allows image acquisition and display of undistorted live images.
Type : Radiotherapy Simulator
Application : Medical Use
Condition : New
...moreCobalt - 60 Radiotherapy Unit - Bhabhatron II
Bhabhatron II, 4th generation cobalt Unit. The latest Bhabhatron II has a best in class provision to carry out 3D Conformal treatment technique. Bhabhatron II is equipped with enhanced features like motorized wedge, auto-setup, asymmetric collimation, computer console, advanced radiolucent patient couch, R&V compatibility, electromechanical and software based anti-collision device, auto-closure mechanism during emergency and remote diagnostic facility to assist proactive maintenance schedule. Its radiolucent couch design, without any metallic part is especially made with a view not to obstruct radiation beams, makes Bhabhatron II an ideal cobalt teletherapy unit for implementing arc therapy and non-coplanar beam based treatment plans for better treatment outcome. Salient Features: Source Head, Safe and Future ready, Capacity up to 250RMM of cobalt-60. Treatment Couch: Fully Motorized Pit mounted iso-centric treatment couch with 4 motorized motions Vertical Longitudinal Lateral Iso-centric Indexed fiber couch top helps accurate and repeatable patient positioning. Fully closable collimator for radiation safety in case of emergency. Automation allows complete control over the treatment and operational parameters. Intuitive and simple workflow that adapts easily to the department's processes. Salient Innovation of BHABHATRON-II Source Head Capacity: 250 RMM Minimum Collimator 3x3cm at 80cm Iso-centre Maximum Collimator Field Size 35x35 cm Safety Interlock System Automatic Collimator closure Arc Treatment Dual Speed motions Auto set up of collimator 8 Hrs Battery backup Computerized Control Console Patient Image display in the control console Auto collision detection wedge sensing Iso-wedge: computerized motorized wedge Super Iso-Wedge Asymmetric Collimator
...moreBe first to Rate