EE 2506 Horizontal Common Mode Choke
Get Price Quote
1 Piece (MOQ)
Notes RoHS 3 compliance is available on most products, subject to our confirmation. Specifications subject to change without notice. Document Number: PEPL-CAT-13 Release: 01/06/2009
High Voltage Ceramic Capacitor
Get Price Quote
500 Piece (MOQ)
Best Deals from Passive Components
Wire Wound Resistors
3 Per Piece
5000 Piece (MOQ)
Choke Inductors
Get Price Quote
100 Piece (MOQ)
MEHVCSDY250A44 Schneider Power Capacitor
8,892 Per Piece
5 Piece (MOQ)
Thermoelectrical Air Conditioners 200 Btu to 5000btu
Get Price Quote
1 Piece (MOQ)
FEATURES Extremely reliable solid state construction with long life span Maintenance free design with no moving components (other than fans) No compressor, refrigerant or filters Compact size, lightweight, convenient to install and operate NEMA 4X construction (Type 304 stainless steel) for indoor or outdoor use Standard models to 140° F (DC version) and 104° F (AC version) (High ambient models available) Through-mount, flush-mount or recessed-mount installation Recommended for vertical mounting only AC or DC power configurations, with built-in adjustable thermostat Built-in condensate drip pan with fittings and drain tubing Mounting gasket and stainless steel fasteners included Complete 12 month warranty OPTIONS Supplemental heating capability Rain shroud – vertical mount Digital temperature controller (remote mount) Recessed frame for mounting entirely inside cabinet Powder coated aluminum construction CE certified units SPECIFICATIONS 200 BTU/HR Cooling Heating Capability Available NEMA 4X (Indoor/Outdoor Applications Vertical Mounting Only 120/220 VAC or 24-28 VDC Power 8-1/4″ H x 6″ W Mounting Flange Made in the USA
Thermoelectrical Air Conditioners 200 Btu To 5000btu
Get Price Quote
Capacitors, Controller, DOL Air Brake Motor Starter
Box Type Capacitor
15 - 30 Per Piece
1000 Piece (MOQ)
Box type Capacitors of all range avaiable.
Aluminum Cylindrical Capacitor
Get Price Quote
We are instrumental in providing supreme quality Aluminum Cylindrical Capacitor to clients across the world. The range of Aluminum Cylindrical Capacitor housings comes with Stud and Flange. These Aluminum Cylindrical Capacitors are extensively used by the TOP capacitor Manufacturers in India. We offer the Aluminum Cylindrical Capacitors at affordable rates to clients. Specifications : Studs upto the length of 30mm Standard M8, M10 and M12 threads Used By : TOP capacitor manufacturers
chip capacitors
Get Price Quote
We keep stock wide range of chip Capacitors kits of sizes 01005, 0201, 0402, 0603, 0805, 1206.
three phase chokes
Get Price Quote
Three phase chokes are used at the input circuits to reduce harmonics. Three phase choke assemblies are also used in esp surge protection equipments. It can be used as dc filter chokes. Ac input three phase chokes are also used for VFD’S
Mylar Capacitors
0 Per Piece
Measuring Capacitor
Get Price Quote
We offer state of the art SF6 gas filled Standard Capacitors, Measuring Capacitors & Coupling Capacitors to our clients. Our Standard Capacitors are suitable for integration with capacitance and Tan Delta Bridge for accuracies in the range of 10-5. The offered Standard Capacitor is customized and available at very reasonable price. Furthermore, the Standard Capacitor provided by us is known for its high performance and durability. In addition we make oil filled measuring & coupling capacitors for HVAC & Partial Discharge measurements in the range of 60kV to 800kV (100pF to 1000pF)other capacitance ratings also available as per customer requirements.Features :As a Standard Capacitor (Reference) for Tan delta measurements. The capacitor is manufactured with state of the art technology reliable, rugged and maintenance free.Available Ranges : Standard Capacitors : 50KV - 300KV, 100pF and 400kV, 50pF Coupling & Measuring Capacitors : 60kV to 800kV in 100pF & 1000pF models. Other capacitance ratings can be designed & supplied as per customer requirement.
ferrite core inductor
Get Price Quote
Rod Core Inductor
5 Per Piece
Aluminium Electrolytic Capacitor
Get Price Quote
For the attainment of the complete clients' credibility, we issue an invoice to them including all the relevant information regarding products as well as agreed price. We are a quality-driven firm and actively engaged in making an available high-quality range of products that are designed and developed using the premium raw material. Aluminium Electrolytic Capacitor has a high-strength body with excellent heat and chemical resistance.
Capacitor
20 - 300 Per Numbers
AC Capacitor i) FanCap 440V Series Capacitor ii) Metal FanCap 440V Series Capacitor iii) Super FanCap 440V Series Capacitor iv) Fan OilCap 440V Series Capacitor v) Ultra Eco MotoRun Cap 250V Series Capacitor vi) Eco MotoRun Cap 250V Series Capactior vii) MotoRun Cap 440V D Series Capacitor viii) MotoRun Cap 250V Series Capacitor ix) MotoRun Cap 440V Series Capacitor x) Metal MotoRun Cap 440V Series Capacitor
toroidal inductor
Get Price Quote
Toroidal inductor, DC – DC Converter Transformers are used in step-up or step-down converters. These transformers can be used in self-saturated or square wave driven applications. These ultra-miniature transformers are made for durability while maintaining their electrical characteristics. Custom designs are available to increase or decrease secondary voltages as well as any specific input voltages. • POWER AND CHIP INDUCTORS • TOROIDAL INDUCTORS • TRANSFORMERS • ROD CHOKES • IRON POWER INDUCTORS • CUSTOM TRANSFORMERS
neutral grounding resistor panel
5,000 - 10,000 Per Piece
We offer the Power+N range of Neutral Grounding Resistor (NGR) Panels up to 66 KV. Ngr’s are used to connect the neutral phase and the earth to limit the earth fault current to a safe value thereby protecting the transformer, generator system. The Typical operation conditions are A No Earth Fault: Continuous current (5 % to 10 % of full load current) may pass through the resistor due to system unbalance or Earth Fault Condition where restricted fault current passes through the resistor protecting the system till automatic protection takes place. Power+N Neutral Grounding Resistor Panels upto 66 KV Purpose: Neutral Grounding Resistor is connected between the neutral & the earth so that it will limit the earth fault current to a safe value [Normally full load current of the generator, transformer, etc. thereby protecting the transformer, generator system].Typical operation conditions:1. No Earth Fault: Continuous current (5 % to 10 % of full load current) may pass through the resistor due to system unbalance.2. Earth Fault Condition: Restricted fault current passes through the resistor protecting the system till automatic protection takes place. The earth pressure (Rated Voltage) is absorbed by the resistor protecting the winding etc. Salient Design features: Enclosure: For outdoors application enclosure designed to give degree of protection of IP 33 is normally used. Enclosure upto IP 65 protection are offered. Enclosure material can be Mild Steel, Aluminium or Stainless Steel. Painting / Galvanizing or Hot Dip Galvanizing or Powder Coating is offered as per requirement. Safety screen enclosure is provided if required. For continuous rating enclosure protection is not above IP 43. Material of Resistor Element: A Neutral Grounding Resistor is a very simple yet technical equipment that is an absolute requirement depending on the design of the installation. Our NGR panels are fitted with resistor elements made from stainless steel or cast iron or CU-NI or NI-CR or any other resistance material as per requirement. From our experience, formed stainless steel elements are best and economical for NGRS. Construction: NGR include resistor assembly, plus required insulators, internal connections and hardware. Options/Accesories: Few of the following are usually incorporated. Current Transformers, Potentials Transformers, Grounding Transformers, Two bushing, Elevating Stands, Manual/ Electrical operated/ Motorized Isolator, Earth Leakage Relay, Lightning Arrestors, Auxiliary Control Wiring Terminal Box with Cable Glands, Termination Kit, Stand Off Insulator, Space Heater with Thermostat Control are also offered. Cabling/ Termination: Suitable arrangement is provided for termination of cable, flats or bus duct as per requirement. Incase of XLPE cable terminal box with suitable clearance and undrilled removable gland plate is provided. Typical Specifications: Rated Voltage: In an NGR this voltage means value of line to neutral voltage (ie System Voltage divided by 1.732) Rated Current: This is the value of initial current that will flow through resistor when it is cold. Normally rated current value is same as full load current. Duty rating or Time Rating:Also referred to as Duty rating, is length of time for which NGR must withstand rated voltage. Short Time Rating: This is dependent on the design parameters of the protection system, normally it is 10 or 30 or 60 seconds. When a fault is immediately cleared and system made healthy then chances of fault repetition should be considered. 30 sec is the typical rating recomemded b y IS-304. Continuous Rating: This is typically 10 % of full load current. For a healthy systems the NGR can be designed for a continuous rating of 5% to 10 % of full load current. Temperature Rise Allowed: Normally Temp. Rise is restricted to 375 deg.c ie as per BS 587. It can be 760 deg.c. As per IEEE-32. We can offer NGR of any other temp. Rise as per the design requirements.
Current Sense Resistors
Get Price Quote
Current Sense Resistors We keep stock wide range of chip resistors of sizes: , 0603, 1206, 2010, 2512