Sf6 Breaker Panels
5,000 - 10,000 Per Piece
Rated Current : 630A,800A,1250A,2000A,3150A
Dimension : W800 x D1350 x H2100 mm
Breaker : SF6 breaker (HPA)
Supply Voltage : 3.3kV,6.6kV and 11kV
Short Time Current Rating : 40 kA
Degree of protection of panel : IP4X,IP5X
Panel Model : SF6 Indoor Panel (Power + F)
Busbar : Electrical grade Aluminium or 99.9% Oxygen Free Copper
The Power +F are an Indoor SF6 Switchgear Panels. For compactness in panels rated up to 2000A special bus raiser panel is provided with bus coupler panel extended in the rear side. IP4X degree of protection is provided externally and IP2X between compartments. Panels shall have adequate space for terminating large cable sizes. Features: Modular & compact for better strength and flexibility in extension. Fully Compartmentalized construction for optimal safety and protection For compactness in panels rated upto 2000A special bus raiser panel is provided with bus coupler panel extended in the rear side. IP4X degree of protection is provided externally & IP2X between compartments. Our design enables adequate space for large cable sizes. Even larger cables and additional runs rear extension is provided for cost effectiveness. Independent exhaust vents for all HT compartment are provided for natural cooling and exit for any flue gasses. Dedicated Circuit breaker compartment as per internationally proven ABB design. Cassette mounted ABB Circuit Breaker with draw out feature for easy maintenance and fail-safe safety. Live parts covered by automatic metallic shutters when breaker is racked out. Electrical anti-pumping design avoids mishaps due to mishandling of the breaker. Additional feature includes a separate Racking in/out mechanism which is provided in the breaker which can change from test to service positions and vice versa with the cubicle door closed. Only Branded and type tested sub components are used in our panels. Current and Voltage transformers are placed in chamber below Circuit breaker to avoid any kind of flashovers which may damage the breaker. Wiring done with flexible copper cable affirming to IS 694 for Longitivity and Durability. Optional integral earth switch can be provided on the cable side for Earthing. We provide Foundation frame as standard supply All hinged doors are provided with gaskets to keep away dust and water from the electrical components. Multiple guides are provided for safe and sure engagement of fixed and moving contacts. Breaker trolley shall be given along with the breaker panel for maintenance. Our Design Standards: Breaker IEC 62271-100 Current transformer IS 2705/1992 and IEC 60044-1 Potential transformer IS 3156/1992 and IEC 60044-2 Busbar IS 5082 for Aluminium Sheet Steel: IS 513 Cables IS 694