SMPS Transformers
Get Price Quote
We are the main supplier of this product.
Constant Voltage Transfermors
Get Price Quote
A ENERGX CVT, the AC mains powers the input which is widely separated physically from the solated output winding. The input winding normally runs at very moderate Flux linkage levels. The output winding exhibits energy characteristic and this energy storage operates in conjunction with mains capacitor to produce self generated AC flux field which is indirectly excited from the winding. The result is instantaneous voltage regulation and spikes. Sine wave output. A perfect answer for every electronic equipment.
Best Deals from Transformers
Constant Voltage Transfermors
Get Price Quote
Silica Gel Breather, spherical silica gel beads, Silica Gel
Tap Position Indicator
Get Price Quote
Started our business operations as manufacturer, supplier, exporter and trader, we are engaged in offering TAP Position Indicator. Suitable for industrial environment, thee indicators are offered with potentiometer provision for trimming, in order to compensate the lead resistance. Apart from this, to ensure robust construction, these indicators are checked thoroughly. Features: Functional accuracy Precise reading Durable finish Details: Visual 7 segment digital display Onoff switch with lamp indication provided for power supply status Potentiometer provision for trimming to compensate the lead resistance Panel mounting with aesthetic value Robust & Rugged i.e. suitable for industrial environment Greater degree of accuracy & consistent reliability Specifications: Auxiliary Voltage 110 or 230 or 415V AC +15%, 50 Hz Resistance Tel-transmitter 1 kilo OHMS per step, 3 wire connection Display 1 to 99 positions 2 digit 7 segment LED display Accuracy Tolerance + 2% Lead compensation Trough a potentiometer adjustment in the front fascia Type of mounting Panel Mounting Operating temperature 0°C to 55°C Break down voltage 2KV, between all live terminal connected together and body for 1min Dimensions in mm 96 mmx96 mmx70 mm (Panel cutout size:90mmx90mm+0.1 -0.00) Applications: OLTC panel to indicate tap position
Single Phase Transformer
1,250 - 2,000 Per NOS
5 Piece (MOQ)
Electrical Transformer
Get Price Quote
2 Amp Transformer
100 Per Piece
100 Piece (MOQ)
Package Series of Voltage Transformers
Get Price Quote
Types : For any specific project including lamination or ferrite cores Any other customer made types Applications : Weighing Scales Ups Voltage Stabilizers Energy Meters
Single Phase Transformer Coils
Get Price Quote
Electronic Ignition Transformer
Get Price Quote
Single Phase Control Transformer
Get Price Quote
Isolation Transformers
Get Price Quote
Features: * Complete electrostatic shielding &grounding. * Reduces power line noise, spikes & transients. * Total isolation from input and output. * Three phase to single phase conversion. Applications: * Analytical and Bio-Medical equipments. * CNC processors and peripherals. * Computer and peripherals. * Digital communication equipments. * Instrumentation and Telemetry. * Special purpose machinery. * Telecommunication equipment.
LV Voltage Transformers
Get Price Quote
We manufacture L.V. Voltage Transformers in Tape insulated & Cast resin types. These are widely used in various industries for measuring & protection purposes. Applications Control panels and switch boards Protection relays/Relay panels Earth fault protection Power control centers
PCB Mountable Transformers
Get Price Quote
PCB Mountable Transformers, conventional transformers, Current Transformer
l t transformers
Get Price Quote
We manufacture LV Transformers that are widely demanded by clients for effective performance, low regulation, high efficiency, good power back up, easy installation and flawless performance. These are insulated with VPIEpoxy Resin to ensure hassle free functioning. We also offer customized solutions to clients as per their varied requirements. It has been used for Isolation, lighting load, control circuit, thyristor, rectifier circuit etc….
dimmerstats
Get Price Quote
dimmerstats, Transformers, Batteries, Inverters, Ups, Power Supply
Three Phase Transformers
Get Price Quote
Three Phase Transformers, Auto Transformers, CONTROL TRANSFORMERS
Single Phase Isolation Transformer
Get Price Quote
Single Phase Isolation Transformer is available in variegated technical specifications. We hold expertise in manufacturing, exporting and supplying quality transformer that are used on all systems that require grounding on the load. Our isolation transformer is a copper wound, multi-shielded, single phase, K-factor rated, high efficiency, power conditioning isolation transformer. It is duty rated and belongs 600 volt class. This isolation transformer supports harmonic rich non-linear loads while maintaining safe operating temperatures. Easy to install and maintain, this isolation transformer is reckoned for its high quality, efficiency and reliability. Standards : The power conditioning system is designed in accordance with applicable portions of the following standards: American National Standards Institute (ANSI C57.110 & C62.41-1991) Institute of Electrical and Electronic Engineers (IEEE 519-1992) National Fire Protection Association (NFPA) 70, National Electrical Code (NEC) Federal Information Processing Standards Publication 94 (FIPS Pub 94) UL Listed to Standard 1561 C-UL listed to CSA Standard C22.2, No. 47-M90 Input Specifications : Nominal AC input voltage ratings: 480 VAC, 240 VAC or 208 VAC, 1 phase, with sufficient margin to sustain a constant input of +10% without saturation. The nominal operating frequency: 60 hertz + 3 hertz. The power conditioning system’s primary is configured single phase, two wire, plus ground, and includes full capacity taps at 2½ % increments, two (2) above and four (4) below the nominal voltage tap. Energizing inrush current will not exceed 10 times the full load input current for ½ cycle. Performance Specifications : Load Regulation : Maintained within +2.5% or less of nominal, from no load to full load. Overload : 500% for 10 seconds, and 1,000% for one cycle. THD : ≤ 1% added to the output voltage waveform under a linear load. Output Voltage : Sinusoidal with no flat topping when high crest factor (3.0 : 1), non-linear loads are present at the output. Audible Noise Measured at 1 Meter from the Unit : ≤ 50dBA Electrostatic Shielding : Incorporates two, or an optional three, solid copper foil electrostatic shields which minimize inner winding capacitance, transients, and noise coupling between primary and secondary windings. Common Mode Noise Attenuation : 126 dB with two shields, or 146dB with optional three shields. Transverse Mode Noise Attenuation : 3 dB down at 10kHz, decaying 20 dB per decade. Optional TVSS : Incorporates a fused (with front panel mounted, blown fuse lamp indicator), secondary connected, 3 mode spike suppression network. The TVSS is comprised of high energy metal oxide varistors with less than a 5 nanosecond response time and a maximum peak current handling capability of 40,000 amps (8x20μsec) per mode. Thesuppression network system will remain functional when subjected to ANSI/IEEE C62.41 Category B-3 waveforms. The spike suppression network increases the transverse mode noise attenuation to 3 dB down at 10kHz, decaying 40 dB per decade. Main Transformer : Transformer Windings : All copper conductor construction, with separate primary and secondary, isolated windings. The transformer conforms to NEC article 250, that specifies a separately derived power source. The neutral conductor is sized for 200% of the ampacity of the phase conductor.Terminals are provided for isolated single phase output conductors, neutral conductor and ground. All leads, wires and terminals are labeled to correspond with the circuit wiring diagram. Basic Impulse level : No less than 10,000 Volts. MTBF : ≥ 200,000 hours. Transformer Steel : Grain oriented, M6 grade, silicon steel. Flux density : ≤ 15k gauss. Core losses : ≤ 0.6% of the KVA rating. Insulation : Class N, 200OC with a maximum temperature rise of 115OC above ambient, not exceeding 130OC under nonlinear loading per UL 1561. Cooling : Natural convection. Cabinet : Enclosure : NEMA type 1, floor mounted, and indoor enclosure. Construction : Cabinets are manufactured from 14 gauge steel with base sub-structure suitable for fork lifting. Paint : Baked on, powder coat paint finish with proper pre-treatment. Provisions exist to hardwire input and output power connections to terminals located within the unit enclosure. Input and output conduit landing locations are available on the rear of the unit enclosure. Environment : Operating Temperature Range : -20OC to +40OC. Humidity : 0 to 95% non-condensing. Altitude : Up to 5000 feet above sea level without de-rating. Warranty : Manufacturer guarantees equipment to be free from defects in material and workmanship for a period of 2 years following shipment from the factory
halogen transformers
Get Price Quote
halogen transformers, Electronic Chokes, pulse ignitors, open type ballast
Tap Position Indicator
Get Price Quote
Prok dv’s make TAP POSITION INDICATOR (TPI) uses state-of-the-art dedicated hardwareto indicate the transformer tap position through two digit Seven segment LED displays, whileconnected to a remote transformer work, Tap position from 1 to 99 steps will be indicated bythe unit, increment of the readings will be in steps of one (each step represents 1 k- ohm),A potentiometer has been provided in front fascia of the unit, which can be used tocompensate the connecting lead resistance at site, ON/OFF switch provided in the front fasciawhich indicates the power on status of the unit.Note: If Terminal point 17- Variable point of tap position is open shows decimal point in theSeven segment displayPotentiometer shall be set to marking in the front faciaTAP Specification Transformer TAP- Steps Indication by means of 2 digit,Seven Segment Display. ON/OFF Switch in the Front facia with lamp indication to display the power input status Leads compensation through Potentio meter fine adjustment in the front facia Flush mounting Robust and rugged design, suitable for industrial environment