LV Voltage Transformer
Get Price Quote
transformer oil filter machine
Get Price Quote
We are offering transformer oil filter machine.
Best Deals from Transformers
audio transformer
Get Price Quote
In other words, the transformer transforms the Impedance of the speaker, so that the impedance which it presents to the primary winding is equal to the load of the Output stage active element (tube to transistor). The purpose of this Transformer is to match the Impedance of the loudspeaker or a number of loudspeakers to the optimum load of the tube or transistor.
Dimmer Stat
Get Price Quote
We are manufacturer and exporter of continuously variable Auto Transformers, Variacs and Dimmer stat which operates on a nominal voltage of 240 V A.C & can give output voltage anywhere between 0 – 270 V, by a simple transformer action. The basic Auto Transformer is meant for operation off a nominal voltage of 240 V A.C & can give output voltage anywhere between 0 – 240 V or up to 270 V, by a simple transformer action. Three such Variable Auto transformer when connected electrically in star & mechanically in tandem, became suitable for operations of 415 V 3 Phase A.C. supply & to give output of 0 – 415 V or up to 470 V.
Three Phase transformer
Get Price Quote
Apart from online payment processing methods, we also facilitate payment through offline mediums. We follow strict quality procedures that are as per the guidelines, help us in presenting dependable and cost-effective product range. We offer high quality three phase transformer. Additional Information : Item Code - TPT-01
Transformer Wire
Get Price Quote
Transformer Wire
converter transformer
Get Price Quote
One of the main differences from other types of transformers is that the load currents contain higher harmonics due to the distorted waveform. The converter to the transformer causes the distorted current waveform. This has to be considered current leads to higher losses & temperatures in the transformer. Network regulations also require reduction of harmonic distortion. These transformers are used in applications where a variable speed is required on the motor shaft. They are used in a wide variety of applications such as rolling mill drives, ship propulsion systems, mine hoist drives, wind tunnels drives etc. The figure below shows a basic circuit diagram for a system configuration for a wind tunnel. The transformer is a 12-pulse unit that feed two 6-pulse rectifiers, which are connected to two inverters, which in turn is connected to a synchronous motor. The transformer is also equipped with a tertiary winding, which is to reduce the harmonic voltage distortion in the HV supply system as increasing the power factor of the load.
Ferrite Series of Voltage Transformers
Get Price Quote
Types : Ee, Ei, Ec, X Drum Core Etc. Pot Cores Any other Customers Made Applications : Smps Transformers Matching Transformers [i/p & O/p] Loading Coils Coupling Transformers Telecommunication Power Supplies, Control and Switching Applications.
Furnace Transformers
Get Price Quote
We offer a qualitative range of furnace transformers that are designed and manufactured using cutting edge technology, meant to be used with arc or induction furnaces.
UI Transformer
Get Price Quote
Miracle Electronic’s UI Transformer consists of a range of high quality low profile encapsulated isolating transformers with twin 115V AC 50/60 HZ primary windings which are connected in series for 230V or parallel for 115V operation. Miracle Electronic’s UI Transformers / Low Profile Transformers come with Double section glass fibre reinforced polyamide bobbins. Our UI transformers are 100% electrical and Flash tested, have low radiated nose and possess low inter-winding capacitance. Miracle Electronic’s UI Transformers: Making the most of devices. Miracle Electronic’s UI Transformers are extremely durable, come with superior wiring, varnishing, connection terminators. Our UI Transformers are indeed highly efficient and provide excellent regulation with minimal temperature rise. All our UI Transformers are RoHS Compliant, High and Reach Compliant. General Product Features & Inclusions Low Profile Low Inter winding Capacitance 5 KVA Primary /Secondary Insulation CRGO core UI cores Cold Rolled Grain Oriented steel cores Thermal fuse – Optional Class B / F Insulation Epoxy PCB Mounting arrangements Product Variants available: Range of 2 VA, 4 VA, 6 VA, 10 VA, 14 VA, 18 VA, 24 VA 120 /240 V 1 Phase, 50 Hz Miracle Electronics also undertakes requests for custom design and development of UI Transformers. Please contact our Customer Support Team for more details.
Oil Immersed Transformer
Get Price Quote
2000kva11kv433v , 50hz copper wound Oil immersed Power Transformer as per Is2026.
transformer coil
Get Price Quote
transformer coil, Pcb Mount Transformer, Commercial Led Lightings
Electrical Laminations
Get Price Quote
Electrical Laminations
Three Phase Isolation Transformer
Get Price Quote
We are a reputed firm engaged in offering precision-engineered Three Phase Isolation Transformer. It is a continuous duty rated, 600 volt class, convection cooled, dry type, isolation transformer to support harmonic rich non-linear loads while maintaining safe operating temperatures. This transformer includes superior transverse and common mode noise attenuation. Designed as per NEMA TP 1-2002 dry type transformer efficiency standards, our transformer is acknowledged for high performance and reliability. We provide Three Phase Isolation Transformer in variegated specifications to meet diverse applications. Standards : The power conditioning system is designed in accordance with applicable portions of the following standards NEMA TP 1-2002 Dry Type Distribution Transformer Efficiency Standards American National Standards Institute (ANSI C57.110 & C62.41-1991) Institute of Electrical and Electronic Engineers (IEEE 519-1992) National Fire Protection Association (NFPA) 70, National Electrical Code (NEC) Federal Information Processing Standards Publication 94 (FIPS Pub 94) UL Listed to Standard 1561 C-UL listed to CSA Standard C22.2, No. 47-M90 Input Specifications : Nominal AC input voltage ratings: 600 VAC, 480 VAC, 240 VAC or 208 VAC, 3 phase for transformers below 225kVA,and 600 VAC or 480 VAC, 3 phase for transformers 225kVA and above. All are designed with sufficient margin tosustain a constant input of +10% without saturation. The nominal operating frequency: 60 hertz + 3 hertz. The power conditioning system’s primary is configured in a three phase delta. Transformers below 500kVA include full capacity taps at 2½ % increments, two (2) above and four (4) below the nominal voltage tap. 500kVA transformers include full capacity taps at 2½ % increments, one (1) above and two (2) below the nominal voltage tap. Energizing inrush current will not exceed 10 times the full load input current for ½ cycle. Output Specifications : Output Voltage : Sinusoidal with no flat topping when high crest factor (3.0 : 1), non-linear loads are present at the output. Audible Noise Measured at 1 Meter from the Unit : ≤ 50dBA for 15 KVA to 112 KVA ≤ 55dBA for 150 KVA to 225 KVA ≤ 60dBA for 300 KVA to 500 KVA Electrostatic Shielding : Incorporates two, or an optional three, solid copper foil electrostatic shields which minimize inner winding capacitance, transients, and noise coupling between primary and secondary windings. Common Mode Noise Attenuation : 126 dB with two shields, or 146dB with optional three shields. Transverse Mode Noise Attenuation : 3 dB down at 10kHz, decaying 20 dB per decade. Efficiency : 98% typical and meets NEMA TP 1-2002 dry type transformer efficiency standards on models 15kVA and above. The power conditioning transformer is designed to achieve NEMA TP 1-2002 Table 4-2 efficiencies listed below under a K-4, K-7, or K-13 non-linear load at or between 35% to 50% load and at an operating temperature of 75 degrees C. KVA Efficiency : 15* 30 97.00% 97.50% 50 97.70% 75 98.00% 112 98.20% 150 98.30% 225 98.50% 300 98.60% 500 98.70% *15kVA model efficiency applicable to K4 and K7 loading only. Optional TVSS : Incorporates a fused (with front panel mounted, blown fuse lamp indicator) 3 phase, secondary connected, 6 mode spike suppression network. The TVSS is comprised of high energy metal oxide varistors with less than a 5 nanosecond response time and a maximum peak current handling capability of 40,000 amps (8x20μsec) per mode. The suppression network system will remain functional when subjected to ANSI/IEEE C62.41 Category B-3 waveforms. The spike suppression network increases the transverse mode noise attenuation to 3 dB down at 10kHz, decaying 40 dB per decade. Main Transformer : Transformer Windings : All copper conductor construction, with separate primary and secondary, isolated windings. The transformer conforms to NEC article 250, that specifies a separately derived power source. The neutral conductor is sized for 200% of the ampacity of the phase conductor. Terminals are provided for isolated three phase output conductors, neutral conductor and ground. All leads, wires and terminals are labeled to correspond with the circuit wiring diagram. Basic Impulse level : No less than 10,000 Volts. MTBF : ≥ 200,000 hours. Transformer Steel : Grain oriented, M6 grade, silicon steel. Flux Density : ≤ 15k gauss. Core Losses : ≤ 0.6% of the KVA rating. Insulation : Class N, 200OC with a maximum temperature rise of 115OC above ambient, not exceeding 130OC under nonlinear loading per UL 1561. Cooling : Natural convection. Cabinet : Enclosure : NEMA type 2 general purpose, floor mounted, and indoor enclosure. Construction : Cabinets are manufactured from 14 gauge steel with base sub-structure suitable for fork lifting.
Low Voltage Transformers
Get Price Quote
Low Voltage Transformers, Electrical Transformers, Transformer
Single Phase Transformer Coils
Get Price Quote
Power Transformers, Control Transormers, Isolation Transformers
Get Price Quote
We are offering power transformers, control transormers, isolation transformers.
Power Distribution Transformer
Get Price Quote
Power Distribution Transformer
Dry Transformers
Get Price Quote
Dry Transformers, AC Electric Motors, dc electric motors
Single Phase Pad Mounts Transformers
Get Price Quote
Single Phase Pad Mounts Transformers, Single Phase Pole Mounts