Deluge Valve
1 - 1 Per piece
1 Piece (MOQ)
Deluge Valve
42,000 Per Piece
Best Deals from Deluge Valve
Deluge Valve
35,399 Per Piece
1 Piece (MOQ)
Deluge Valve
5,000 Per Piece
DELUGE VALVES, ALARM GONG BELL
38,000 Per piece
5 Nos (MOQ)
Deluge Valve
65,000 Per Piece
SC-7001 Deluge Valve
Get Price Quote
Deluge Valves Models 7001 are manufactured with Dry Trim (Pneumatic Actuated) and Wet Trim (Hydraulically Actuated). Both options are available with Electrical Trim Solenoid Actuated (Model 1110). All trims are factory piped on the Valve itself. It also has Manual Station as Test Trim, Manual Override and Drain Line. The valve opens on demand to provide water flow to the fire protection sprinkler system. Pilot system can be hydraulically, pneumatically or manually operated. Opening of the Valve is by electrical signal to solenoid valve/loss of control pressure. The Pilot and Diaphragm design has many advantages as... Quick respose/fast opening Low friction High flow capacity Minimum maintenance Imported Diaphragm & Patented Quad Seal Ring for zero leakage. Size : 25NB - 400NB
Deluge Valve
Get Price Quote
Deluge Valve
50,000 - 500,000 Per piece
1 Nos. (MOQ)
Deluge Valve
Get Price Quote
We offer wide array of fire fighting equipments like hydrant valve, nozzles,hose coupling and more at the most reasonable price. Features: I. Deluge Valve is known as a system control valve in a deluge system, used for fast application of water in a spray system. II. Deluge valve protects areas such as power transformer installation, storage tank, conveyor protection and other industrial application etc. III. With the addition of foaming agent deluge valve can be used to protect aircraft hangar and inflammable liquid fire.
Deluge Valve
Get Price Quote
The Deluge Valves manufactured by us finds application in Fire detection, Fire extinguishing systems. Manufactured using Cast Iron / Cast Steel parent materials, it is also tested for flow capacity in our factory where we have set of pumps, pipe line. Deluge Valve is manufactured in adherence to International UL Standard and in case of fire its supplies water immediately. Features : Durable Quick action Smooth operation Highly efficient Required For : Water motor alarm Fire extinguishers Pre-action system Water spray project system Drench system Size : 50 mm to 150 mm General Manufacturing Standard : UL : 260
Deluge Valve
Get Price Quote
The assistance of our sophisticated packaging system and skilled personnel, we are able to meet the standard as well as customized packaging requirements of the clients with ease. As we are backed by a well-developed network and modern transit facilities, we are able to meet the requirements of the customers located in Vadodara(India).
Deluge Valve
Get Price Quote
Safex Deluge Valve are designed to minimize the friction loss inside and inner parts such as clapper are made of cast bronze to offer excellent corrosion and pressure resistance.
Deluge Valves
Get Price Quote
Construction :CI / CS / DI / Al. Br. ➣Max Pressure :12 Bar ➣Size :80 NB to 200 NB ➣Accessories : a) Wet / Dry Pilot Trimb) Water Motor Gong ➣Approval :UL
Deluge Valve
Get Price Quote
Deluge valve that is opened by the operation of a smoke or heat detection system. The detection system is installed in the same area as the sprinklers. When the detection system is activated water discharges through all of the sprinkler heads in the system. Deluge systems are used in places that are considered high hazard areas such as power plants, aircraft hangars and chemical storage or processing facilities. Deluge systems are needed where high velocity suppression is necessary to prevent fire spread.
Deluge Valve
Get Price Quote
Fast application of water in spray Pre-action and foam system Size: 50, 80, 100, 150 & 200 mm. (2″, 3″, 4″, 6″ & 8″) Cast iron body & cover Maximum service pressure 12 bar (175 PSI) Bronze Seat Flanged connection dimensions to ANSI B 16.1 Diaphragm operated with rubber to metal drip-tight positive sealing Reset without any tools Service without removal from line Easily trimmed for actuation by manual, remote solenoid valve & with dry or wet pilot Internal and external surfaces epoxy coated for extra protection
Deluge Valve
Get Price Quote
Specifications * Pressure Ratings : Class:150-300 # * Temperature Ranges : -40 to 90 deg. C. * Standard Materials : Stainless Steel * 150-400 mm ASTMA 216 Gr. WCB & Alloy Steel
Deluge Valve
Get Price Quote
Model DV-5, Deluge ValveDeluge Valve, External Resetting Diaphragm Style – 11/2" thru 8" Model DV-5 Deluge Valves are diaphragm type valves designed for vertical or horizontal installation for fire protection system service. They are used as "automatic water control valves" in deluge, preaction, and special types of fire protection systems such as foam-water systems. When properly trimmed, the DV-5 Valves provide actuation of fire alarms upon system operation. The unique diaphragm style design of the DV-5 Valve allows external resetting. Deluge or preaction systems can be reset without having to open a valve handhole cover and manually reposition a clapper or latch mechanism. Simply repressurizing the diaphragm chamber resets the valve. The one-piece, diaphragm style design of the DV-5 allows standard internal and external coating of the valve to provide corrosion resistance. The internal corrosion resistance offered by the Rilsan coating makes the DV-5 suitable for most seawater and brackish water supplies when utilized in deluge systems. The external corrosion resistance of the Rilsan coating permits the use of the DV-5 in corrosive atmospheres associated with many types of industrial processing plants and outdoor installations. Tech Data TFP1305 Tech Data TFP1305A – Aluminum Bronze Alternative Materials of Construction • Available sizes: 11⁄2" (DN40), 2" (DN50), 3" (DN80), 4" (DN100), 6" (DN150), and 8" (DN200) • Vertical or horizontal installation • One internal working part • No linkage or clapper assembly • Light weight ductile iron body • Available with deluge and single & double interlock preaction trim • Internally & externally coated • Features external resetting • Diaphragm operation • For most seawater & brackish water supplies • For deluge, preaction & foam systems • Available as Flange x Flange, Flange x Groove, or Groove x Groove body styles • Rated for 250 psi service • Listings and Approvals: UL, C-UL, & FM
Deluge Valve
Get Price Quote
Deluge Valve
Get Price Quote
Deluge Control Valves
Get Price Quote
Deluge valves are hydraulically actuated, pilot operated diaphragm control valve.Two basic designs are available FT100-straight pattern & FT 1100-angle pattern. All internal parts and cover are 100% identical in both the designs.
Deluge Valve
Get Price Quote
Deluge valve, Deluge Valve Control Panel: Client: THERMAX, Project: Mahan Aluminum Project (MAP), Project: Singrauli, Infrastructure Electrical & Panel Assembly of Panels. Fabrication (at present outsourcing) HV testing kit 0-5KV ACDC (1 set) Meggeer and all other electrical measurement & testing kit.
STRAIGHT TYPE DELUGE VALVE
Get Price Quote
FLOW TEK DELUGE VALVE are intended to deliver large quantities of water over a large area in a relatively short period of time. The flow tek Deluge Valve is UL approved to 250 psi G. (17.5 bar) in sizes 2", 2½", 3", 4", 6", 8", 10", (50,65,80, 100, 150,200 & 250 MM ). The FLOW AGE deluge Valve is compact, lightweight, and is provided with a preassembled trim - all of which minimize the installation time and make it simple and easy. The FLOW AGE Valve opens fast, yet smoothly, preventing water hammer. The FLOW AGE Valve design prevents false tripping and it can be reset by a thumb-activated knob. STRAIGHT TYPE DELUGE VALVE DETAIL -UL Listed Local Resetting - Once the deluge valve operates, it is latched in an open position Remote Resetting - The FLOW TEK Deluge Valve can be remotely reset. The FLOW TEK Deluge Valve is designed to allow for a variety of detection and release systems: Hydraulic Actuation ( WET PILOT TRIM) Wet pipe systems are the most common fire sprinkler system. A wet pipe system is one in which water is constantly maintained within the sprinkler piping. When a sprinkler activates this water is immediately discharged onto the fire. Advantages to using a wet pipe fire sprinkler system include: System simplicity and reliability - Wet pipe sprinkler systems have the least number of components and therefore, the lowest number of items to malfunction. This produces unexcelled reliability which is important since sprinklers may be asked to sit in waiting for many years before they are needed. This simplicity aspect also becomes important in facilities where system maintenance may not be performed with the desired frequency. Relative low installation and maintenance expense - Due to their overall simplicity, wet pipe sprinklers require the least amount of installation time and capital. Maintenance cost savings are also realized since less service time is generally required compared to other system types. These savings become important when maintenance budgets are shrinking. Ease of modification - Wet pipe fire sprinkler systems are advantageous since modifications involve shutting down the water supply, draining pipes and making alterations. Following the work, the system is pressure tested and restored. Additional work for detection and special control equipment is avoided which again saves time and expense. Short term down time following a fire - Wet pipe sprinkler systems require the least amount of effort to restore. In most instances, sprinkler protection is reinstated by replacing the fused sprinklers and turning the water supply back on. Pre-action and dry-pipe systems may require additional effort to reset control equipment. Disadvantages to using a wet pipe fire sprinkler system include: Wet pipe systems are not suited for sub-freezing environments. There may also be a concern where piping is subject to severe impact damage and could consequently leak. Pneumatic Actuation (DRY PILOT TRIM) A dry pipe sprinkler system is one in which pipes are filled with pressurized air or nitrogen, rather than water. This air holds a remote valve, known as a dry pipe valve, in a closed position. Located in a heated space, the dry-pipe valve prevents water from entering the pipe until a fire causes one or more sprinklers to operate. Once this happens, the air escapes and the dry pipe valve releases. Water then enters the pipe, flowing through open sprinklers onto the fire. Advantages of using dry pipe fire sprinkler systems include: Dry pipe sprinkler systems provide automatic protection in spaces where freezing is possible. Typical dry pipe installations include unheated warehouses and attics, outside exposed loading docks and within commercial freezers. Many people view dry pipe sprinklers as advantageous for protection of collections and other water sensitive areas. This perceived benefit is due to a fear that a physically damaged wet pipe system will leak while dry pipe systems will not. In these situations, however, dry pipe systems will generally not offer any advantage over wet pipe systems. Should impact damage happen, there will only be a mild discharge delay, i.e. 1 minute, while air in the piping is released before water flow. Disadvantages of using dry pipe fire sprinkler systems include: Increased complexity - Dry pipe systems require additional control equipment and air pressure supply components which increases system complexity. Without proper maintenance this equipment may be less reliable than a comparable wet pipe system. Higher installation and maintenance costs - The added complexity impacts the overall dry-pipe installation cost. This complexity also increases maintenance expenditure, primarily due to added service labor costs Lower design flexibility - There are strict requirements regarding the maximum permitted size (typically 750 gallons) of individual dry-pipe systems. These limitations may impact the ability of an owner to make system additions. Increased fire response time - Up to 60 seconds may pass from the time a sprinkler opens until water is discharged onto the fire. This will delay fire extinguishing actions, which may produce increased content damage. Increased corrosion potential - Following operation, dry-pipe sprinkler systems must be completely drained and dried. Otherwise remaining water may cause pipe corrosion and premature failure. This is not a problem with wet pipe systems where water is constantly maintained in piping. With the exception of unheated building spaces and freezer rooms, dry pipe systems do not offer any significant advantages over wet pipe systems. Electric Actuation VALVE WILL BE OPERATED BY SOLENOID VALVE, WHICH WILL BE OPERATED BY ANY POWER SUPPLY 220 V , 230 V , 24 V DC, ETC..
Deluge Valves
Get Price Quote
Features Model H2 - Cast Steel ASTM A216 WCB construction Rated for maximum 17.5 Bar (250 PSI) operating pressure Size: 50, 80, 100, 150 & 200 NB Globe pattern Vertical or Horizontal mounting UL Listed
Deluge Valve
Get Price Quote
Aarush Fire Systems Pvt. Ltd are the service provider of Deluge Valve. These products are manufactured using superior-quality basic material and contemporary technology under the watchfulness of skillful crew of personnel. Features High performance Longer service life Easy installation
Deluge Valve
Get Price Quote
UL listed Made out of Cast Iron Rated pressure 175 PSI Test Pressure 350 PSI
Deluge Valves
Get Price Quote
Deluge Valve
Get Price Quote
we are dealing in this product.which Specification are:- Main Valve Body Ductile Iron ASTM A536 Main Valve Bonnet Ductile Iron ASTM A536 Disc Guide Bronze ASTM B 62 Seat Bronze ASTM B 62 Disc Buna N Rubber Diaphragm Nylon reinforced Buna-N
Deluge Valve
25,000 Per Piece
Deluge Control Valves
Get Price Quote
Deluge valves are hydraulically actuated, pilot operated diaphragm control valve.Two basic designs are available FT100-straight pattern & FT 1100-angle pattern. All internal parts and cover are 100% identical in both the designs.