Reaction Vessel Lamp
1 Piece (MOQ)
Country of Origin : Made in India
pH Controller
Feature : Compact designs,Easy to use,Durable
Hpg Systems
Power Supply : 230 V + 10% 50 Hz. AC
Range : 0.01 uS/cm to 200mS/cm
Accuracy : + 0.5% of range + 1 digit
Range : 0 to 100°C
Accuracy : + 0.5% of range
...moreFlameproof Temperature Scanner
Technical Specifications: Functions Temperature Indicator No. of Channel Six Channel Simultaneous display Display 3 12 digit LED with over range indication Range -199.9 to +199.9 °C OR any other range Accuracy + 0.5% of range + 1 digit Resolution 0.1°C Input 3 wire PT100 OR any other Sensor e.g. Thermocouples)
...moreFlame Photometer
Features: Microprocessor Based with Printer Interface Auto Gas Cutoff Auto Flame Failure Detection Four Measurements in Single Aspiration Setup Storage Facility Sample Data Storage Facility
...moreDissolved Oxygen Meter
Technical Specifications: Function DO & temperature simultaneously Display 16 character x 2 lines alphanumeric BL LCD Power supply 230 V ± 10% 50 Hz AC DO Range 0 to 20 ppm Resolution 0.1 ppm
...moreDigital Temperature Indicator
Technical Specifications: Functions Temperature Process Display 3 12 digit LED with over range indication Range -199.9 to +199.9 °C OR any other range Accuracy + 0.5% of range + 1 digit Resolution 0.1 °C Input 3 wire PT100 OR any other Sensor (Please Specify such as mA. Thermocouples)
...moreConductivity Sensor
Technical Specification: Sensor Type Conductivity Range 0-200mS Resolution 0 .001uS Operating Temperature 0 to 70 °C Accuracy 0.5% of full scale
...moreChannel Scanner
Technical Specifiactions: Display 16x2 LCD with backlight No. of channel 4 Input Type 3- Channel Pt100 and 1 channel 4-20 mA Range -500C to 850 0C for PT100 -1999 to 1999 for mA Resolution 0.1 0C for PT100 0.1 for mA Accuracy 0.2 %
...moreAquaponics Multi Parameter Kit
Features: 1. Float based and timer based control for fish tank and sump tank. 2. Hi, Low, and Sensor failure alarm for all parameters.(No sensor failure alarm for DO) 3. Alarm logs with date and time for all parameters. 4. Parameter logs with date and time. 5. PC connectivity using RS-232 port
...moreTURBIDITY METER
echnical Specifications: Function Turbidity & temp. simultaneously Display 16 character x 2 lines Alphanumeric BL LCD Power supply 230 V ± 10% 50 Hz AC Turbidity Range 0-1000 NTU in Two Ranges Resolution .1 NTU in lowest Range
...moreDigital Conductivity Meter
Functions Conductivity, Temp.(optional) Display 3 12 digit LED with overload indication Power Supply 230 V + 10% 50 Hz. AC Conductivity Range 0.01 uScm to 200mScm Resolution 0.01 uScm on the lowest range Accuracy + 0.5% of range + 1 digit Cell const. adj. Digital 0.1 to 2.00
...moreDigital Tds Meter
Functions TDS, Temp.(optional) Display 3 12 digit LED with overload indication Power Supply 230 V + 10% 50 Hz. AC TDS Range 0.00 ppm to 200 ppm Resolution 0.01 ppm on the lowest range Accuracy + 0.5% of range + 1 digit Cell const. adj. Digital 0.1 to 2.00
...moreDigital Ph Meter
Functions pH, mV, Temperature Display 3.5digit LED, with over range indication Power Supply 230 V + 10% 50 Hz. AC
...moreIncubation Controller
Turning: Automatic and manual turning with user select-able interval and duration. Ventilation: Elite 2000 controls the ventilation automatically based on the temperature and humidity inside the chamber. The ventilation is proportionally opened or closed based on the set values while maintaining the minimum ventilation using complex algorithm.
...moreWeb Scanner
Functions Temperature & RH Display 128x64 graphical LCD No. of channel 16 Channel (8 temp & 8 Humidity)with skip facility Input Type 4-20 mA Range -50°C to 850 °C for PT100 0 to 100 % for RH Resolution 0.1 °C for PT100 0.1 % for RH Accuracy 0.2 % for PT100 3% for RH
...moreDigital Temperature Controller
Technical Specifications: Functions Temperature Process Measurement & Control Display 3 12 digit LED with over range indication Range -100.0 to +200.0 °C OR Any other range (Please Specify) Accuracy + 0.5% of range + 1 digit Input PT100 3 wire OR (Please Specify such as mA, Thermocouples)
...moreTemperature Controller
Technical Specifications: Process Process Range -50 °C to 400.0 °C for Pt100 -1999 to 9999 for mA Accuracy 0.5% Set points 1- 2 as per requirement Hysteresis 0-2 as per requirement Relay Control 1-2 as per requirement(option to set relay control below or above set point) Calibration 2 point manual
...moreOnline Ph Indicator
Functions pH (online) Display 3.5digit LED & over range indication Power Supply 230 V + 10% 50 Hz. AC pH Range 0 to 14 pH continuous Resolution 0.01 pH Accuracy + 0.02 pH (relative) Repeatability + 0.01 pH Input Resistance 1014 ohms
...moreOnline pH Controller
pH Range: 0 to 14 pH Resolution: 0.01 pH Accuracy: + 0.01 pH + 1 digit
...moreFlameproof Flow Totalizer
Functions Flow totalizer calibration pass word protected Display 16X2 Alphanumeric Backlit LCD Programming Through 4 keys Prog, Shift , Inc, reset Flow rate 0-20000 field programmable through software Totalizer 8-digit Accuracy + 0.5% of range + 1 digit
...moreLevel Controller
Technical Specifications: Functions Level Control(LO or HI) Type Conductivity based or Magnetic float based Indication Visual indication of Control relay & Mains Input Conductivity based level sensorfloat type sensor output
...moreLevel Sensor
Technical Specifications: Sensor Type Magnetic Float Based Size As per requirement Diameter 8 mm or as per requirement Material Stainless Steel Fitting 12”, 34” or according to the Flange size ( please specify)