static stabilizer
Get Price Quote
TECHNICAL SPECIFICATION RATING Single phase 3 KVA to 15 KVA Three phase 10 KVA to 30 KVA INPUT VOLTAGE RANGE Standard (Single Phase) 160-300 volts ac, 1-phase, 2 wire, 50Hz Standard (Three Phase) 280-520 volts ac, 3-phase, 4 wire, 50Hz Input Nominal Frequency 47 to 63 Hz Input Nominal Voltage 230 volts ac, 1-phase, 2 wire, 50Hz400 volts ac, 3-phase, 4 wire, 50Hz OUTPUT Output Nominal Voltage 230/400 volts ac, three phase wye Output Power Frequency Better than 96% (with 20-100 % load conditions) Output Voltage Regulation Nominal ± 3 % maximum under 0 to 100 % load & input of 185~265 vac Applications Regulation speed 500V / sec Handles crest factor of 5:1 20ms response time A soft start feature
Servo Voltage Stabilizer
Get Price Quote
We are offering servo voltage stabilizer.our organization supplies and exports very efficient servo voltage stabilizer. We understand that in most industries, even a minor fluctuation in voltage can cause the equipment to malfunction or break down. Therefore, our servo controlled voltage stabilizer efficiently controls the fluctuations in the input voltage and provides constant output voltage with +/- 1% accuracy. It also helps in reducing mdi and save power. The vener7 range of stabilizers is known for their consistent performance and the tremendous benefits they bring to the businesses. Our stabilizers are available from 5 kva to 2000 kva in 3-phase and 1kva to 100 kva in single phase. applications information technologyprocess control equipment (nc/cnc machine, plastic moulding machine etc.)all electrical / electronic equipment (motors, lighting, electrical oven, furnace etc.)medical equipment (cat scan, x-ray machines, physiotherapy etc.)data processing equipment (computers)food processing industrychemical plants, cement plants & textile unitsheavy engineering industries (railway, defence etc.)air conditioningcommercial building & complexescommunication & broadcasting equipmentprinting & packaging industries core core is made from best grade imported cold rolled grain oriented silicon steel lamination with the latest technique of annealing. Interleaved and mitered joints reduce the core losses and magnetizing current considerably. Core is specially designed to sustain over-fluxing up to 12.5%. Core is clamped with steel channels rigidly to reduce the cartite sound level and earthed with electrical grade copper sheet. winding the winding cab be of any type (i) spiral (ii) crossover (iii) helical (iv) disc, designed to withstand the optimum electrical, mechanical, dynamic and thermal stresses depending upon the current and voltage. The coils are wound with electrolytic grade high conductivity, annealed wire and strips covered with high quality insulation. All coils are reinforced, insulated to withstand the effect of short circuits and impulse voltage shocks. Cooling ducts are provided to minimize the hotspot temperature and temperature gradient between winding and oil. insulation and oil the insulation material like pre-compressed boards, blocks, corrugated cylinders, bakelite tube, insulating tapes, empire sleeves, glass sleeves varnish, epoxy bushing, porcelain bushing etc. Are used of best quality to ensure long life to the transformers. Oil used as a coolant and insulating medium is of the best quality conforming to is: 335. Before filling into filtration plant’ and tested to ensure free from moisture and dust. tank and radiator the tanks are made from premium quality mild steel sheets, plates and pipes by electrical welding. Proper bracing and stiffeners are provided for robust construction. The tank are tested at specific pressure for leakage at joints/welds. Sufficient cooling radiators are provided for maximum dissipation of heat during extreme ambient temperatures. The radiators are made from best grade pressed steel fins or elliptical tubes. painting tank surface exposed to atmosphere is painted with two coats of red oxide paint to provide maximum resistance to corrosion and two coats of epoxy based anti-corrosive enamel paint. Surface in contact with oil is treated with two coats of ‘oil and heat resistant paint’. This paint has more effective resistance compared to ordinary enamel paint against corrosion and oil/heat reactions. vector group various vector groups can be provided as per demand. temperature rise our transformers are designed for maximum temperature rise at full rated load 40 degree c/50 degree c for oil/winding for aluminium wound transformers and 45 degree c/55 degree c for copper wound transformers. overloading our transformers are designed for overloading excess than normal rating as per is:6600. fitting and accessories standard fitting recommended in is 2026-1977 are provided. Extra fittings like buchholzrelay, dial type thermometer, winding temperature indicator, marshalling box, h.v. & i.v. Cable boxes, prv and osp are provided as per the requirement of the customers.
Best Deals from Voltage Stabilizer
Servo Stabilizer
Get Price Quote
Servo Stabilizer, Distribution Transformers