Digital Vibrotest Biothesiometer
1 Piece (MOQ)
Country of Origin : Made in India
Type : Portable
Application : Bedside Testing
Weight : 2.5 Kg
Brand Name : VIBROTEST
Feature : Easy tool to quantify neuropathy, Portable Vibration sense, Full solid state design with PC connection
...moreVD8M Vascular Doppler for ABI
1 Piece(s) (MOQ)
A low-cost pocket Ultrasound Doppler. The Uni-directional Hand Doppler model VD8M offers all the standard features of a traditional Ultrasound Vascular Doppler and, intended primarily for vascular applications.Supplied with gel, neck cord, soft padded carry bag, software for ABI calculation and manual.Features : Interchangeable Doppler Probes Unidirectional Doppler 8MHz Vascular Probe is Standard Continuous Wave Doppler 5 and 8 MHz Vascular probes Rechargeable battery operation Charger supplied free ABI Software to generate report are supplied free
...moreVascular Doppler Recorder for ABI / TBI (Versalab LE)
The Ankle Brachial Index (ABI) is a measure of the severity of atherosclerosis in the legs but is also an independent indicator of the risk of subsequent atherothrombotic events elsewhere in the vascular system. The ABI may be used as a risk marker both in the general population free of clinical CVD and in patients with established CVD.Continuous wave Vascular Doppler ultrasound is considered a reliable tool and was validated and accepted into routine medical practice. The literature recognises the importance of assessment in the management of a patient with chronic lower limb ulceration. The evidence from the medical literature indicates that a "normal" ABI is 0.91 or greater, a ratio below this indicating arterial disease.Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the "normal ABI range" (0.91 to 1.4) or sometimes in the non-physiological range of above 1.4. However, Calcified leg arteries in Diabetes Mellitus or dialysis patients may yield falsely elevated ABI results.Pulse volume recording, also known as air Plethysmography, is a noninvasive test that measures blood flow within the blood vessels or arteries. The first sign of possible abnormality is the absence of the dicrotic notch. More significant occlusions will show a decreased slope of the ascending and descending segments and a rounding of the systolic peak. More serious obstructions will show flattened waveforms.A photoplethysmogram (PPG) is an optically obtained Plethysmogram, a volumetric measurement of an organ. The PPG Toe blood pressure and related Toe Brachial Index (TBI) are performed to assess the vascular condition of the foot by obtaining systolic pressures at the toe. Toe pressures may be useful in cases of unsuspected vascular disease and in baseline diabetic foot assessment where falsely high ankle pressures can occur due to calcification of tibial vessel.VERSALAB Auto is capable of conducting ABI, TBI, PVR, Segmental Doppler, Upper Extremity Exam, Carotid and Penile Doppler studies. The blood pressure for the above measurements are done by a built-in mechanism and the BP measurement are validated by the software and helps the user to correct the BP measurement incase of any patient artifact. This quality control method helps to detect the systolic BP accurately.VERSALAB Auto is compatible with any Windows operated computer for data transfer for storage and patient reports. The software has various configurations to conduct ABI/TBI, PVR, Segmental Doppler for lower extremity, Upper Extremity, Carotid examination and Penile flow studies along with the pressues indicesses.This model is a fully automatic model that capture waveforms and blood pressues on its own for accuracy. The built-in quality control helps to detect the accurate and correct systolic BP of all the limbs. Our clients also call this equipment as diabetic doppler.Features : Automated Ankle Brachial Index and Toe Brachial Index Doppler (C.W) with 8MHz Transducer Photo Plethysmography (PPG) Toe sensor ABI/TBI/PVR/Segmental BP/Upper Extremity Doppler Large LCD screen to display parameter Silent pump measures the systolic BP Segmental cuff sets with toe cuff Penile flow study Software for complete arterial vascular profile Computer connectivity enabled Software for data transfer, storage and patient report Software supports Windows Xp(SP3)/ Win 7/ Win 8/ Win10 Standards matching International standards Product Code : VERSALAB Auto
...moreVascular doppler recorder
65,000 - 70,000 Per No
1 Piece (MOQ)
The Ankle Brachial Index (ABI) is a measure of the severity of atherosclerosis in the legs but is also an independent indicator of the risk of subsequent atherothrombotic events elsewhere in the vascular system. The ABI may be used as a risk marker both in the general population free of clinical CVD and in patients with established CVD.Continuous wave Doppler ultrasound is considered a reliable tool and was validated and accepted into routine medical practice. The literature recognises the importance of assessment in the management of a patient with chronic lower limb ulceration. The evidence from the medical literature indicates that a "normal" ABI is 0.91 or greater, a ratio below this indicating arterial disease.Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the "normal ABI range" (0.91 to 1.4) or sometimes in the non-physiological range of above 1.4. However, Calcified leg arteries in Diabetes Mellitus or dialysis patients may yield falsely elevated ABI results.VERSADOP Dx, ABI vascular doppler is compatible with any Windows based computer and get connected through an USB port. The software supplied helps to transfer the waveform data from the unit to the computer for storage and patient report generation.Features : Doppler (C.W) with 8MHz Transducer Software to measure ABI ABI measurement as per TASC II guidelines Penile flow study Arterial and venous examinations made simple Software for complete arterial vascular profile Product Code : VERSADOP Dx
Country of Origin : India
Type : Vascular Doppler Recorder
Certification : ISO13485
Application : Clinical Use, Diagnostic Centre, Hospital
Color : Off-white
Voltage : 230V AC
Condition : New
Power Source : Electric
Equipment Type : Ultrasound Machine
Measurements : Blood Flow
Brand Name : DFCIndia
Item : Versadop Dx
...moreThermometry Hot/Cold - HCP
Loss of thermal perception leads to early stage of diabetic neuropathy and detecting at this stage helps the patient for better control. Our thermometry hotcold products are available with following special features : Non invasive testing of pain thresholdEasy operation with hand remote1 degree to 50 degree C temperature rangeRate : 1 degree C per secondHelps to find cool, warm, hot, and cold perception thresholdsHelps detecting diabetic polyneuropathy at an early stage
...moreSimple Plantar Pressure System (Podiascan)
Feet provide the primary surface of interaction with the environment during locomotion. Thus, it is important to diagnose foot problems at an early stage for injury prevention, risk management and general wellbeing. Although plantar pressure data have been recognized as an important element in the assessment of clients with diabetes and peripheral neuropathy, information derived from plantar pressure data also can assist in determining and managing the impairments associated with various musculoskeletal and neurological disorders. Plantar pressure measurement systems identify and quantify areas of high pressure, helping you diagnose the root cause of lower extremity problems and design more effective offloading devices.The Foot Scanner Podiascan system provides podiatrist and biomechanists with an economical and efficient method to measure static / dynamic plantar foot pressure distribution. The Footscan Podiascan system produces instantaneous and permanent high resolution image of the pressure distribution across the plantar surface. The Foot Scan system Podiascan consist of a Harris mat / Foot Imprinter model FM1111, Windows based image analysis software and patient reporting software. HP make Scanner copier printer model HP 2050 series or equivalent is an optional item. By using our Harris mat in conjunction with scanner and image analysis software, the system produces an enhanced full colour representation of the sole of the foot. We introduced this Original concept in India as early as 2005.Features : Uses Foot Imprinter recording paper Low cost device Software supports Windows Xp, 7, 8 and 10 operated computer Footwear measurement can be entered in the software ABI, VPT, MF scores and measurements can be added in the report Software converts even a very light image without dropping the image Export in pdf option Patient report can be directly emailed from software to a footwear supplier Data backestore Original design Diagnostic uses include : Identifying areas of potential ulceration Pre and Post surgical evaluation Determining the degree of pronation and supination Screening diabetics and other neuropathy patients Monitoring regenerative foot disorders Determination of orthotic efficacy PODIASCAN system is supplied with Foot Imprinter Harris Mat(with accessories), An interface box to computer, A licensed software with hardlock to capture and convert the gray scale image inot a multi color scale and generates a patient report.Product Code : Podiascan
...morePortable Vibration Sense Machine
5 Piece(s) (MOQ)
VibraTip: a wipe-clean, pocket-sized and disposable device for testing vibration sense. Vibration sense is typically one of the first sensory modalities to be impaired as peripheral neuropathy develops. Graduated tuning forks (e.g. Reidel-Seiffer) and calibrated electronic devices (e.g. Neurothesiometer,Bio-Thesiometer (Vibrometer) are recommended to quantify the integrity of vibration sensation. VibraTip is a wipe-clean, disposable, key fob-sized device that provides a constant and reproducible source of vibration. The spherical head facilitates application from any angle and its pocket size means that it is easy to carry and therefore likely to be available at the point of use.
Brand Name : McCallan
...morePodiatry Kit (Full)
The Podiatry Kit (Full) comprises of simple and essential podiatry instruments that are used for removing corns, callous, nail cutting, nail trimming and corn shaving. All the instruments are made from high quality stainless steel which may be autoclaved. The additional tools help the podiatrists manage the foot well. The full kit consists of 10 essential podiatric tools.Features : 4.5 " Corn Shaver Cuticle nipper 4.75" Nail cutter barrel spring handle 5.5" Nail cutter Moon-shape double spring Spoon with probe Pusher with elevator Nail File 4.5" Toe nail scissor straight 4" Nail Cutter Straight shape Double ended Scalpel with #10 and #15 surgical blades Product Code : FULL
...morepodiatry instruments
11,000 - 11,500 Per Piece
1 Piece(s) (MOQ)
The podiatry full kit comprises of simple and essential podiatry instruments that are used for removing corns, callous, nail cutting, nail trimming and corn shaving. All the instruments are made from high quality stainless steel which may be autoclaved. The additional tools help the podiatrists manage the foot well. The full kit consists of 10 essential podiatric tools.
Type : Podiatry Instruments
Material : Stainless Steel
Application : Clinical, Hospital
Country of Origin : India
...morePodiatry Chair
1 unit (MOQ)
Condition : New
Waterproof Type : Waterproof
Model Number : PC302
Brand Name : DFCI
Weight : 95 kg
Feature : Sturdy construction, Seamless finish, Compact design
...morePC Based Vascular Doppler Recorder VERSALAB LE
One of our fast moving manual Ankle Brachial Index machine with 8 MHz Doppler and Toe PPG sensor. Along with ABI, we can also measure Toe Pressure with this unit. Most of the diabetes patients will have an elevated ankle pressure and the ABI will be more than 1.3. The only way to assess the blood circulation during this is the measurement of absolute Toe pressure, which is possible with this unit. This unit is PC compatible and PC enabled. The software is very comprehensive and it allow the user to have ABI study, Simple Vascular study where 16 different blood vessels can be selected for screening and also the complete Vascular study where the user can select upto 51 different blood vessels to screen. Features : 8 MHz unidirectional doppler transducerPhoto plethysmography (PPG) for toe pressure measurementSegmental cuffsets with manometer for ankle brachial indexPC software for storage and printout on A4 size plain paperLight weight and portableManual ankle brachial index studyMonitoring & Recording of velocity & pulse volume waveformsPenile flow studyGets connected on to any computer (computer not included) through RS232 serial portUSB to Serial converter cable available
...morePC Based Vascular Doppler Recorder VERSALAB Dx
VERSALAB Dx incorporates all the features of VERSALAB LE and additionally a built-in thermal printer enables the user to print the waveform on a standard thermal paper which is used for the ECG or EKG machines whenever it is not connected to PC. Features : Doppler 8 MHz transducer3 pieces segmental BP cuff setLCD monitor and chart recorderScreens peripheral arteries, venous and cerebro vascular disordersPrognosis of healing of ulcers using PPGGets connected on to any computer (computer not included) through RS232 serial portPhoto-Plethysmography (PPG) for Toe Pressure measurementVelocity and pulse volume waveformsAnkle Brachial index (ABI) studyStudy of stiffness of arteryAssess penile erectile dysfunctionPC software for printout on A4 size plain paper
...moreNA03 Neuropathy Assessment Kit
Peripheral neuropathy is the prime pathogenic ingredient in the recipe for diabetic foot ulceration. Ulceration, in turn, is the key factor that may precipitate a cascade of events leading to lower- extremity amputation. Clearly, identifying the presence of neuropathy (or more pragmatically, clinically significant loss of protective sensation) and taking action before any breach in the epithelium is of enormous import in any screening and treatment program designed to prevent amputation. Several modalities have been advocated to assist in this endeavour. Current research promotes early detection of neuropathy so that secondary prevention measures, such as intensive foot-care education and treatment, can be used for individuals.We have packaged three important simpler devices for the effective management of diabetic neuropathy. They are TipTherm, VibraTip and Monofilament 10gm.TIP THERM is an early diagnostic device for symmetrical polyneuropathy which measures temperature sensitivity of the skin. TIP THERM was developed to give the clinician and patient a convenient and easy to use method of testing. It works up to a temperature of 23o C.VIBRATIP is a device resembling a small key fob that provides a near-silent vibration of consistent amplitude at a frequency similar to that of a calibrated tuning fork. It is intended for use when testing a person's vibration perception during routine checks for diabetic peripheral neuropathy (DPN) in people who have type 1 or type 2 diabetes. Monofilaments are an effective, convenient, easy to use, relatively inexpensive way of testing for loss of protective sensation in the feet in daily clinical practice.
...moreNeuropathy Analyzer
120,000 - 125,000 Per unit
1 Piece (MOQ)
Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988).Small-fiber Test provides an easy-to- use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy.Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of foot. Digital Biothesiometer helps us to quantitate the threshold and monitor progressive changes or trends on following up testing.Sensory neuropathy increases the risk of foot ulcerations by seven folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major casual factors in the development of foot ulcerations among diabetic subjects.Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high risk group This model is a Proprietary item and solely manufactured by us in India.Our product VIBROTHERM Dx is one of our Proprietory Equipment.Features : Full solid state design with PC enabled Easy Tool to quantify Neuropathy Digital Biothesiometer and Thermometry HCP combined Digital 0 ~ 50 Volts Vibration output 1 ~ 50o C temperature output range 1o C rate of change per second Remote keypad helps easy operation Single probe delivers both Hot & Cold temperatures Automatic interpretation based on set values Early detection of Small Fiber Neuropathy Software supports Windows XP(SP3) / Win 7 / Win 8 / Win10 Patient report storage, export, pdf options available USB interface Product Code : VIBROTHERM Dx
Country of Origin : India
Type : Neuropathy Analyser
Certification : Iso13485:2016
Application : Bedside Testing, Clinical, Hospital
Voltage : 220V
Condition : New
Display Type : Digital
Frequency : 50 Hz
Power : 30-60W
Driven Type : Electric
...moreNeuropathy Therapy Stimulator Instead
Keeping up with the latest trends, we strive to achieve utmost customer satisfaction. We, as a Manufacturer, Exporter and Supplier, of Neuropathy Therapy Stimulator Instead, deliver immaculate quality to our customers. It is flawlessly formulated by our experts using top notch raw material and modern technology. The quality we provide is ensured to be in synchronization with industrial standards of quality. Our valued customers can avail this impeccable quality from us at industry leading prices. Details : Item Code: Neurostim-Home The NeuroStim is an electro-therapy has proven to be highly effective in treating a number of conditions, such as: Diabetic Nerve Pain Peripheral Neuropathy Diabetic Peripheral Neuropathy Carpal Tunnel Syndrome Chronic Inflammatory Demyelinating polyneuropathy Muscle Spasms Peripheral Arterial Disease Stroke Rehabilitation NeuroStim helps in healing by accomplishing the following : Stimulates leg muscles to contract and relax thereby increasing blood velocity and volume with fresh blood to the nerves and muscles Stimulates all the afferent and efferent nerves in the lower extremities Draws axon and dendrite nerve endings closer together to facilitate proper nerve transmission Builds residual pain relief each time the system is used Causes the brain to release endorphins that reduce global pain and anxiety Promotes the healing of non plantar surface diabetic skin ulcers and sprains Increases muscle strength for safe, pain free walking Reduces edema as muscle contractions encourage lymphatic drainage and movement to the proper nodes Increases collateral circulation, stimulating vasculogenesis Production Capacity : 250 per month
...moreNeuropathy Therapy Stimulator Hospital Model
1 Piece(s) (MOQ)
To cater to the customers’ needs with excellence, we are engaged in offering Neuromuscular Stimulator Therapy Hospital Model. As a leading Manufacturer, Exporter and Supplier, we offer a premium quality range. It is made of top drawer raw material. Its accurate design, durability and high performance make it an irresistible proposition for the customers. For our esteemed customers, we make it available at easy on the pocket rates.The NeuroStim has proven to be highly effective in treating a number of conditions, such as : Diabetic Nerve Pain Peripheral Neuropathy Diabetic Peripheral Neuropathy Carpal Tunnel Syndrome Chronic Inflammatory Demyelinating polyneuropathy Muscle Spasms Peripheral Arterial Disease Stroke Rehabilitation NeuroStim helps in healing by accomplishing the following : Stimulates leg muscles to contract and relax thereby increasing blood velocity and volume with fresh blood to the nerves and muscles Stimulates all the afferent and efferent nerves in the lower extremities with a signal larger than normal to re-establish the pathways for subsequent normal signals to follow Draws axon and dendrite nerve endings closer together to facilitate proper nerve transmission Builds residual pain relief each time the system is used Causes the brain to release endorphins that reduce global pain and anxiety Promotes the healing of non plantar surface diabetic skin ulcers and sprains Reduces edema as muscle contractions encourage lymphatic drainage and movement to the proper nodes Increases collateral circulation, stimulating vasculogenesis
...moreIR LED Light Therapy Professional
1 Piece(s) (MOQ)
Actively engaged in offering a wide array of IR LED Light Therapy Professional, we are a renowned Manufacturer, Exporter and Supplier. This product is made of using supreme grade essential material and advanced tools & machinery so as to protect its optimal quality principles & norms. The quality is measured against industrial standards by our qualified team of auditors. Our product is available at reasonable price for our valued customers.Details : Patients with diabetes and subsequent poor circulation are difficult to treat when a patient presents with a history of falls, repeated infections, neuropathic pain and ulcers. It is clear that clinicians who face their patients daily, who present with pain, circulation deficits and psychological issues, need a simple, cost-effective method for the patients to experience relief. Neurolite Therapy is a medical device that emits infrared light at a wavelength of 890 nm along with visible LED light at a wavelength of 660nm, and can be applied to any area of the body, which may provide a relief for the patients. Neurolite Therapy device can be utilised safely by a Medicare Professional or by the patient themselves at home. Neurolite Therapy device deliver monochromatic infrared light and visible LED light through therapy arrays, each treatment pad containing 30 super luminous IR diodes and 20 LED diodes. Positive results are expected after 6 treatments of 30-40 minutes duration. There are different sizes pads cater to different applications. Neurolite Therapy device helps the patient if they can use early on to relieve pain, increase microcirculation, promote healing and relieve muscle spasm, it is possible to decrease pain levels, decrease the number of falls, the number of injuries and the necessity for amputations. It is also possible to increase the patient’s level of activities and quality of life, (due to reduction in pain) as well as overall patient compliance and satisfaction. Clinical applications include treatment of acute pain/injuries, chronic pain and or poor circulation in the extremities, diabetes, vascular diseases, muscle spasm/ stiffness and many more applications. Features : Infra-red LED and RED led activated Continuous or Pulsed (292Hz) operation Increase vascular efficacy Stimulate the production of collagen Stimulate the release of tri-phosphate (ATP) Stimulate fibroblastic activity Stimulate tissue granulation and connective tissue projections Stimulate acetylcholine release Reduce the excitability of nervous tissue Benefits Pain and Numbness in Extremities Stimulate the production of collagen Increase lymphatic system activity
Warranty : 1 year
Feature : Improving lymph circulation, Anti-aging, skin rejuvenation
Certification : CE Certified
...moreInfrared LED Light Therapy
Infrared Light Therapy, or photo-biomodulation, is a unique therapy that harnesses the healing powers of infrared light. It emits specials wavelengths of light energy that dramatically increase circulation to injury sites and areas of chronic pain. The result is a rapid relief of discomfort, improvement in sensation, and regeneration of damaged tissues.. The greatest physiological responses are achieved through a unique combination of power, wave length, duty cycle, viewing angles, voltage, frequencies, LED densitysq.cm and overall coverage.
...moreL150R Hand Held Vascular Doppler
The L150R Hand Held Vascular Doppler is an instrument that detects blood flow using the principles of the Doppler effect. It can be a very useful tool in assessing how good the blood flow is to the foot or hand. ABI Hand Doppler test is a painless test and very similar to taking blood pressure using a stethoscope. It is particularly useful for assessment of arterial disease but can also be used for venous problems. This Doppler Ultrasound system is imported from Summit Doppler, USA.Supplied with gel, soft padded carry pouch, ABI BP cuff with Manometer, software for ABI calculation and manual.Features : Interchangeable Doppler Probes Unidirectional Doppler 8MHz Vascular Probe is Standard Continuous Wave Doppler 4, 5 and 8 MHz Vascular probes Rechargeable battery operation Charger supplied free BP cuff with Manometer for ABI measurement ABI Software to generate report are supplied free The LifeDop L150R features a non-display, hand held vascular Doppler with superior sound quality, extended battery life, enhanced probe sensitivity, interchangeable probes and one year full warranty. It includes a battery recharging system so you don't have to worry about overcharging or draining of the batteries.Applications : Ankle Brachial Index Study Arterial and Venous blood flow examination Carotid Bifurcation Penile artery study Specifications : Dimensions (H,W,L) - 140 x 70 x 35mm Weight - 320 grams Battery Life - 1000, 1 minute operation Battery Voltage - 3 Nos. (AA, NMHI, 1.5Volts) Audio bandwidth - 350Hz ~ 2KHz Product Code : L150R
...moreFoot Scanner Model Podiastat
1 Per
1 Piece(s) (MOQ)
Country of Origin : Made in India
FM1111 Foot Imprinter Harris Mat
16,800 - 17,500 Per piece
2 Piece (MOQ)
Early identification of feet 'at risk' for ulceration is important in preventing plantar lesions in diabetic patients with insensitive feet. Plantar pressures are higher in diabetic neuropathic patients than non-diabetic and non-neuropathic Counterparts. As high plantar pressure is a proven risk factor for foot ulceration, effective screening for high plantar pressures in diabetic patients could have a major influence on the incidence of diabetic foot ulceration.In order to identify high-risk patients in a clinical setting, a simple system for screening is needed which is easy to use, reliable and gives results which are easy to interpret and can be immediately available to both the patient and staff. Our Foot Imprinter Harris Mat FM1111 has been developed as a simple, inexpensive and practical foot pressure measurement device intended for routing clinical use. It is a semiquantitative footprint mat which quantifies plantar pressure by visual comparison between the greyness of the footprint.Features : Measures and display patient weight disbursement in grey scale Detects the area of the greatest concern for ulceration Useful to identify Charcot arthropathy Arch of the patient can be detected More the darker colour represent the high pressure Excellent tool for motivating the patient to upgrade to a better and functional footwear. Full Kit include FM1111 Harris Mat, Rubber roller, Ink pad, Ink and Recording Paper(100 sheets).Product Code : FM1111
Country of Origin : India
Type : Foot Imprinter Harris Mat
Material : Rubber
Shape : Rectangular
Style : Modern
Application : Clinical Application
Color : Green
...moreFoot Imprinter Harris Mat
In order to identify high-risk patients in a clinical setting, a simple system for screening is needed which is easy to use, reliable and gives results which are easy to interpret and can be immediately available to both the patient and staff. Our Foot Imprinter Harris Mat FM1111 has been developed as a simple, inexpensive and practical foot pressure measurement device intended for routing clinical use. It is a semiquantitative footprint mat which quantifies plantar pressure by visual comparison between the greyness of the footprint.Excellent tool for motivating the patient to upgrade to a better and functional footwear.
...moreFoot Imprinter
16,500 Per Unit
Application : Clinical, Hospital
Brand Name : Podiascan
Electronic Foot Pressure Plate (Podiastat)
Podiastat is a diagnostic tool for early recognition of altered pressure patterns in the individual with diabetes. It was documented that during the roll-over process, the neuropathic forefoot displayed increased and longer loadings than the healthy forefoot. The neuropathic patients also exhibited a "slap" gait. The load on the heel and toes was lower the areas of highest risk for tissue breakdown.Podiastat has 1600 array of sensors across the sensor plate that can accurately measure Static, Dynamic, multi-Dynamic and Postural measurements. Software helps to show the gait movement in 2D, 3D with provision to measure angle and draw in the measured data. A video camera can be connected to generate a video of foot movement in sync and serves as a mini gait lab.Features : Resistive platform based sensor Prints screen copy or 1:1 foot size Number of sensor 1600(40 x 40) Active sensor area 400mm x 400mm Maximum Pressure 100N per cm2 2D and 3D pictures of pressure point Displays foot roll-over frame by frame Displays Gait line(centre of pressure) Generates Maximum pressure picture (MPP) Measures and records foot pressure in static, Dynamic and Postural modes