Transformer Monitoring System
We are offering transformer monitoring system. The mr make advanced transformer monitoring systems which are promoted by easun - mr monitor all parameters of transformer which can be individually adapted to your specific requirements with the option of different add-on modules. It is also possible to flexibly combine and adapt or expand the functions with customized signal assignment of board input outputs. in transformer monitoring system following monitoring functions are included: top oil temperature & winding temperature ambient temperature tap position capture load current load voltage
...moreTap Changer Spares
We offer tap changer spares. Easun - mr (emr) recommend to use genuine spares from easun - mr. This will ensure assured, continued superior performance of our tap changers. In order to ensure quick supply of spares, we have kept a huge stock of various spare parts in our plant service center ready to service you at any point of time. These parts are very economical backed up by our 1 year warranty. Use of genuine easun - mr spares and services also assures you that all the latest development modifications are incorporated while buying from us. It goes without saying that each component supplied by us is fully tested in our works before it is handed over to you.
...moreon-load tap-changer
The on-load tap-changer vacutap® avt with vacuum interrupters and integrated motor drive serves as switching element and for setting the ratio of dry-type transformers under load.
...moreoil surge relay
We are offering oil surge relay. The protective oil surge relay (osr) is used to protect the malfunction developed inside the on load tap changer (oltc). It is installed in the pipe between oltc head and oil conservator. any malfunction builds pressure which leads to increased oil flow. This protective relay triggers the tripping circuit when the oil flow exceed the specified limits, thus making the transformer to be turned off and contain the damager to the oltc and transformer. osr is fitted with special reed switch which assures rust free contacts even after decades after installation thereby is alert for operation. This osr is designed and tested for very intensive seismic levels. osr is a part of the oltc and its properties are subject to iec 60214.
...moreoctc distribution transformer
We are offering octc distribution transformer. Max. Rated through-current (single-phase) 1200a max. Rated through-current (three-phase) 800a max. Rated step voltage 3300kv max. Rated switching capacity single phase 1000kva max. Voltage for operational equipment um 245kv operating positions without change-over selector(linear) 10
...moreMotor Drive Unit
We are offering motor drive unit. N ma-2 step by step operation takes place by snap action switch. Ma-2 motor drive unit can be used "d", "3 x mi", and “1 + 2” type oltc models. 1hp motor is used in ma-2. The drive mechanisms built with a specialized series of gear to arrive at smoother operation. In ma-2 revolution per tap change is 33 rev. Ma-2 is tested for ip-56 protection. Special housing is also available for ip-65 protection.
...moreMA-9 motor drive unit
We are offering ma-9 motor drive unit. Ma-9 motor drive unit step by step operation is by cam action switch. ma-9 can be used for "v", "l" and "m iii" type oltc model. in ma-9 revolution per tap change is 30rev. less mechanical operation takes place in ma-9 gear unit. 0.75hp motor is used in ma-9. ma-9 is tested for ip-56 protection. Special housing is also available for ip-65 protection. the drive mechanisms built with a specialized series of gear to arrive at smoother operation.
...moretap changers
Opening Hours