pH Meter
Get Price Quote
1 Piece (MOQ)
SANSEL make digital pH meter is a precise and rugged instrument Carefully designed for the most accurate measurement of pH in Laboratories and industries. The instruments are completely IC version using “MOFSET” input “OP - AMP” and CMOS ICS. It is a met al cabinet of elegant shape. All the controls that are in regular use have been incorporated in the front panel for operational easy. The instrument is capable of measuring millivolts with auto. Polarity for redox potentials and potentiometric tirations. This instrument Operates from 180V to 230V AC 50Hz.Features Highly reliable and accurate meter. Very responsive combination glass pH electrode. Latest ICs used for quick sensing and high accuracy. Adjustable temperature compensation. Input is compactable for any type of electrode. SLOPE 4.00 and CAL 7.00 adjustment controls are provided on front for recalibration of instrument. Accessories Basic Instrument Combined Electrode 4 & 7 pH standard tablet with container Electrode Clamp & stand set Instruction manual Optional Imported certified Standard buffer Solution (Extra charge) Epoxy body imported Combined Electrode (Extra charge) 4 & 7 pH standard tablet with container (Extra charge)
FFT Analyser
Get Price Quote
We are the main supplier of this product.
Best Deals from Elemental Analyzer
INDUSTRIAL PH METER
Get Price Quote
Total Organic Carbon Analyzers
Get Price Quote
The Series 6700 covers a complete range of Total Organic Carbon (TOC) Analyzers capable of addressing a wide variety of industrial applications for process and environmental compliance purposes. Depending on the application, TAI can provide an recommendation as to which technique would be best suited to continuously detect TOC within your process. UV / Heated Persulfate Combustion Ozone Promoted Ultrapure Each configuration is available with an advanced Microsoft Windows-based computer with touch screen control. The robust and reliable Infrared CO2 analyzer is the heart of each design. It provides specific, interference-free CO2 detection, has no moving parts, and is extremely easy to access and service, as required. Depending on your specific needs, TAI is capable of providing a complete turn-key system solution suitable for use in hazardous, outdoor environments. Applications: Boiler feedwater; Cooling water; Wastewater; River water; Pharmaceuticals; Process control
cone type soil ph moisture meter
9,800 Per piece
1 p (MOQ)
soil ph value is a very important factor in the production of quality crops. most cropscannot survive in soil that is too acid or too alkaline. therefore the correct ph reading isessential to achieve optimum results. usage: to measure the ph and moisture value of different kinds of soil.range: ph= 3 - 8 ph moisture: 1 - 810%–80% resolution: ± 0.2 phaccuracy : ± 0.2 ph-suitable for agricultural field and classroom experiments.operating temp: 5-50°c (41-122 degrees fahrenheit).calibration: remove oxidation from metal rings by light polishing.
protein analyzer
Get Price Quote
We are supplying products like as Protein Analyzer KjelTRON: Rapid AUTOMATIC NITROGEN Digestion SYSTEM (ISO 9001:2008 & CE Certified) Consists of MULTIFUNCTIONAL KjelTRON Superior PC Compatible SERIES KDIGB Auto sequencing MACRO & MICRO BLOCK DIGESTION SYSTEM (Kjeldhal, Diacid, Triacid, Trace Metal etc). Application: Suitable for all type Soils, water, plants material, Pesticides, fertilizers, food & feed, Milk & Dairy products Dairy products, Starch, cereals, Animal feeds, Fish feed, & many more). Kjeldahl Nitrogen Digestion system: Model-KDIGB 4M: Superior Auto sequencing Microprocessor Based Four samples Macro tube Digestion Block With Programmable PC Compatible controller Two Line LCD Display System Compatible with AOAC, EPA, DIN approved procedures. Nitrogen Digestion system: Model-KDIGB 6M: Superior Auto sequencing Microprocessor Based Six samples Macro tube Digestion Block With Programmable PC Compatible controller Two Line LCD Display System Compatible with AOAC, EPA, DIN approved procedures.
Diesel Smoke Meter
Get Price Quote
Conforms to IS : 4553 – derived from ISO 6 4 : 999. Measures smoke opacity of diesel vehicles in % opacity and K value. Measurement principle : Partial flow, optics based on folded geometry. Suitable for free acceleration test. Engine RPM measurement – vibration sensor based and Battery based. Engine oil temperature measurement. Operates on 230V AC (or) 2V DC power supply. Portable, Compact & light weight design, suitable for “Road tests” using vehicle battery. Low & High voltage indication for battery operation. Automatic Zero and Span calibration. Automatic Pressure regulation and moisture separation. Handheld, Menu driven LCD remote control unit. Pass / Fail indication and emission limit in printout. Vehicle no., vehicle specification, operator name and test data in printout. RS232C serial port for PC interface.
Power Quality Analyzer
Get Price Quote
Fluke 438-II Power Quality and Motor Analyzer Overview The new Fluke 438-II Power Quality and Motor Analyzer adds key mechanical measurement capabilities for electric motors to the advanced power quality analysis functions of the Fluke 430 Series II Power Quality Analyzers. Quickly and easily measure and analyze key electrical and mechanical performance parameters such as power, harmonics, unbalance, motor speed, torque and mechanical power without the need of mechanical sensors. Fluke 434-II, 435-II and 437-II Power Quality Analyzer users can add motor analysis capabilities to their existing units with the Fluke-438-II/MA Motor Analyzer upgrade kit. How it works Using proprietary algorithms, the Fluke 438-II Power Quality and Motor Analyzer uses three-phase current and voltage waveforms to calculate motor torque, speed, load and efficiency at a 1 second update rate. The motor air gap field, as observed via the voltage/current waveforms, provides the basis for the measurements. Mechanical sensors and intrusive no-load motor testing are not required, making it faster than ever to analyze overall electric motor performance. Motor Types The Fluke 438-II can analyze both direct-on-line motors and motors powered by variable frequency drive (VFD) systems. The VFD must be a voltage controlled system (VSI) with a voltage / frequency range of 40 to 70Hz, and a carrier range of 2.5kHz to 20kHz. Electrical motor analysis The Fluke 438-II provides a complete breakdown of electrical parameters. Prior to beginning motor analysis, it's recommended to make base line power quality measurements to assess the state of harmonics and unbalance on the electrical service output as these two properties can have a serious negative impact, on motor performance. When in Motor Analysis mode, results are summarized for electrical performance, mechanical performance and derating (according to NEMA recommendations). The easy to understand four-level color severity scale indicates motor performance in relation to the recommended electrical parameter levels including rated power, power factor, unbalance and harmonics. For mechanical power you can instantly view the mechanical output power along with motor torque and speed. The mechanical output power is instantly compared with electrical power to provide you with live efficiency measurements. With this feature you can easily measure machine performance during each operation cycle. The NEMA derating screen is updated as the load and the electrical conditions change, and each new measurement is plotted on the tolerance graph as a "+". In this example we can see that motor is within tolerance but is close to the service factor. This indicates that there may be a need for power quality mitigation, motor maintenance or some other performance improving adjustment. By frequently performing these tests over time, known benchmarks and performance trends can be created, enabling informed maintenance investment decisions.
Fuji Electric Gas Analyzers
8,000 Per Units
ph testers
Get Price Quote
ph testers, Wind Speed Sensor, temperature calibration bath
Gas Analyzers
Get Price Quote
SICK offers a broad range of gas analyzers based on a variety of powerful measurement principles. With its in-situ and extractive measurement technology for equipping complete facilities, SICK can also provide solutions for a variety of systems and complex measurement tasks.
oxygen analyser
Get Price Quote
Oxygen Monitor offers exceptional flexibility and reliability with large hi-bright LED display Developed using state-of-the-art design and the latest manufacturing techniques The microprocessor based Oxygen Monitor offer a range of unique standard features that set these models apart from the competition Low Power draw allows the units to operate continuously for 20 hours in the rechargeable battery. Low battery alarm, Sensor Fail alarm, Calibration error alarm. Oxygen sensor providing superior long-term stability and accuracy. Constructed from high impact resistant materials, these rugged instruments provide unparalleled performance under the harshest conditions Ideally suited for use in Neonatology, Respiratory care, and Anaesthesia applications.
high performance liquid chromatograph
Get Price Quote
high performance liquid chromatograph, Analytical Instruments
orp meters
Get Price Quote
orp meters, ultrasonic level transmitters, multi channel dataloggers
Analytical Instrument
Get Price Quote
Analytical Instrument
ph electrode
Get Price Quote
ph electrode
ph indicators
Get Price Quote
ph indicators, Temperature Indicators, ultrasonic level indicators
Table-Top Adwa PH Meter
Get Price Quote
Table-Top Adwa PH Meter, Lint Free Wipes, Laboratory Vortex Mixer
Quantum Analyzer
Get Price Quote
Quantum Analyzer, Sheep Placenta - Remove Wrinkles & Whitening Skin
protein analyzer
Get Price Quote
protein analyzer, Kjeldahl Acid Neutralizer Scrubber, fibre extraction system