neph+TURBILIZER (Serum Protein Analyzer)
24 Piece(s) (MOQ)
We offer neph+turbilyzer serum protein analyzer features: nephelometry technology double channel measurement method lot specific - smart card calibration no calibration failure. No reagent wastage. No manual errors. three step assay procedure: 1. Insert smart card 2. Pipette (r1) reagent + sample 3. Pipette (r2) reagent and print result assay panel: rf crp aso hba1c microalbumin cystatin – c ige ferritin lp (a) d-dimer & many more
...moreHEMONEU (Hemoglobin Meter)
100 Pound (MOQ)
Hemoneu hb meter photometric hb test gold standard hicn reagent individually packed hb test use capillaryarterialvenous blood 5 ul whole blood specimen measuring time 5 sec cal-1 (l) & cal-2 (h) for calibration no biological standard required for testing, meter pre-set store data to the cloud through usb tansfer to the computer �reference standard� for all non hicn tests for comparison.
...moreFOTOMETER
10 Piece(s) (MOQ)
We offer FOTOMETER. FOTOMETER 2011 Semi Automated Biochemistry Analyzer (microprocessor controlled static filters) Advanced & Unique Optics Technology combines the proficiency of eight individual photometers and ensures long life and high precision. FEATURES: • Large adjustable LCD for better egronics • Real time curves for Kinetic Chemistries on the LCD • Filters with individual signal amplifier • Filter selection microcontroller based and not mechanical • Pump tubing easily accessible for check and for easy maintenance • 6 Filter wavelengths: 340, 405, 505, 546, 578, 630nm. (8 Filter with additional 450& 690nm). • Large memory to store 1000 test results • Excellent QC function QC chart can be stored, displayed and printed.
...moreAutomated Erythrocyte Sedimentation Rate Analyzer
24 Piece(s) (MOQ)
We offer Automated Erythrocyte Sedimentation Rate Analyzer. ESR 2010 Automated Erythrocyte Sedimentation Rate Analyzer FEATURES: Modern Infra Red microtechnology. Quick Turn-around time: Easy set up of tests 1. Add specimen to tube 2. Place tube in analyzer 3. Results within 30 minutes Random access analyzer. Use any open chamber to automatically measure, time and report result. Measuring time: 30minutes. 20 tests per hour. Reduced contact with potentially infectious and hazardous blood specimen. Completely "Closed Analysis System" (while using Vacuum ESR tube for testing) prevents the user from potentially hazardous blood specimen.
...moreBilirubin Meter
10 Piece(s) (MOQ)
We offer Bilirubin Meter. Total Bilirubin Meter Bilirbin Meter FEATURES: Best suited for quantitative determination of total bilirubin in blood, for newborn infants. Measurement Principle: Direct Photometric using white-LED as light source. Result in 10 sec. Bi-chromatic reading, 405nm (M) and 578nm(S) filter. Sample Volume: 50µL whole blood for newborn baby bilirubin test. Total Bilirubin in 10s directly, no reagent needed.
...moreA1c Meter
24 Piece(s) (MOQ)
We offer A1c Meter. Description A1c Meter & A1c reagents PROCEDURE: Preparation of Hemolysate: To determine HbA1c, a hemolysate must be prepared for each sample: -Dispense 1ml Hemolysis Reagent into tubes labeled: Control, Patients, etc. -Place 20ul of well mixed whole blood into the appropriately labeled lyse reagent tube. -Mix. -Allow to stand for 5 minutes or until complete lysis is evident. Hemolysates may be stored up to 10 days at 2-8°C. To test sample (hemolystae): 1. Dispense Reagent-1 (R1): 150 uL, into the specail patented 'reaction cuvette' 2. Place the cuvette into the 37 0C incubator (optional accessory, strongly recommended) for 5 min or Stand the cuvette at room temperature for 15 minutes 3. Dispense Hemolysate (pre-processed Sample): 4 uL, into the cuvette 4. Insert Magnetic Card into the machine for multi-point auto-calibration 5. Place cuvette with R1 and Sample into the cuvette holder (~7 sec Onboard AutoMix) Mixing will be followed by inbuilt process of incubation for 30 sec 6. Dispense Reagent-2 (R2) 50 uL, into the cuvette, preferably using the switch micropipette with sensor (optional accessory) with sensor (~7 sec On-board AutoMix) If not using the the switch micropipette with sensor, CONFIRM so that the auto-mixing takes place on board. 7. Result will be displayed on the LCD in 90 sec, and as a printout STORAGE: Store all Reagents refrigerated at 2-8 0C. Store the Reaction Cuvettes in dry and clean place. Do not wash and re-use. Store the Magnetic Card in dry and clean place. Do not try to use it for reagents other the lot no., stated on this card. PERFORMANCE CHARACTERISTICS: Measuring range: 2-14% Lower detection limit: 2% Linear up to 14%
...moreBe first to Rate
Rate ThisOpening Hours