Jumbo Humidity & Temperature Indicator
Get Price Quote
1 Piece (MOQ)
Measurement of relevant Climatic data is becoming more and more important.This Humidity & Temperature Indicator offer Very Accurate Measurement of Relative Humidity and Temperature by Excellent readability of the very High intensity Seven Segment LED Display. The Humidity & Temperature Indicator Housed with roughest Case allow the use in tough industrial environments, Latest Technology and well Proven Sensor Guaranteed Highest Accuracy and Long Term Stable Measurement.Features : 4 Digit 2 Line 2”, 4” , 8” Seven Segment LED Display Temperature Range from - 40 to 125ºC Humidity Range from 0 to 100% RH High Resolution 0.01 or 0.1ºC / 0.1 % RH High Accuracy ±0.3ºC / ± 1.5 %RH Optional 2 relay Output with Individual H / L Set Optional Opto Isolated Retransmission Output Easy Mounting Compact Size and rugged Supply 230 V AC Specifications : Display 4 +4 Digit 2" or 4" or 8" Seven Segment LED Display (Display size depends up on customer requirement) Range "* 0-60°C / 0 -100%RH (Depends on Sensor) Resolution * 0.1 or 001°C / 0.1°/0RH Accuracy "* " Depends on Sensor Mounting Wall Mountable Operating Temp.& Humd. 0 - 50°C / 20 to 95 % RH Non Condensing Power Supply 230V AC / 50Hz Weight 5 kg (Approx.) Optional : Temperature and Humidity Sensor / Transmitter 2 Relay Output with individual High / Low set point Retransmission 4-20mA
Temperature Scanner
Get Price Quote
ICD Temperature Scanner Model No. SCN525 is capable to measure and control the Temperature upto 16 points. It accepts temperature sensors like RTDs, Thermocouple, mV and mA signals from Transmitters. The Scanner is completely user programmable like High/Low set point control action, Auto/Manual operation, Channel grouping, Hold, Pause etc. The Scanner is a single board construction with the latest integrated circuit, so as to reduce component counts. Fast A/D converter is used for quick refreshing of all the channels input and output. Digital Zero / Span calibration eliminates trim pot adjustments and settings are made through key pad. Maximum 4 relay outputs are given for Alarm & Trip controls. Channel grouping optional and control modes are programmable.The Scanner scans all the channels continuously on the background while displaying and generates the Alarm & Trip outputs after comparison with respective settings. The Scanner has two modes of operation:1. Operator Level and,2. Superior Level The operator level permits channel display selection in Auto, Manual, Hold mode and Alarm acknowledge. Whereas supervisory level access, Alarm & Trip setting, group configuration, output delay adjustments, channel pause function, scan time etc. Optionally, external relay box containing Max. 32 relays can be connected through serial link. The scanner is housed in 96 x 192 x 250 mm flush mounting enclosure. FEATURES Microcontroller based design Accepts RTD, Thermocouple, mV, mA High Accuracy with software linearisation Multiplexing by Analog switches Channel pause & Hold facility Two set points per channel Over range & Open sensor indication Programmable scan time, set point & channel pause Alarm and Trip indication for each channel Error compensation at site Digital calibration for each channel Optional : PC Interface Optional : Relay output - Max.32 through external relay unit Compact in size / Modular construction EERAM storage, no battery required Protection against EMI/Stray noise Built-in Watchdog Timer 2 or 4 Relay output APPLICATION Winding temperature monitoring of High Rating Motors,PowerGenerators and transformers Various parts of Engine bed,Ball bearings, Water and Steam pipe of boilers Various points in Sugar mills, Food processing, Chemical, Cement,Fertilizer & Pharmaceutical Industries
Best Deals from Temperature Controller
Temperature Controller
4,000 - 6,000 Per Piece
Temperature Controller
Get Price Quote
4 Digit Micro Controller Based Linearized and High Accuracy Selectable Inputs J, K, R, S, T, Pr-100,/ Programmable Range & Resolution Avoid the Jumper selection from TC to RTD conversion Front Key Programming and Configuration Universal Supply 90 to 270V AC 15A Relay output Selectable On Off/Time proportional/Auto tune PID All type of Temperature Sensors with different dimensions are available on request
Digital Temperature Controller
2,500 Per Piece
Programmable Temperature Controllers
Get Price Quote
Chiller Temperature Controller : A special action for -50.0ºC to 50.0ºC range having independent setting for tember as well as delay time (time m for which Comres- sor has to rest before restarting) Hysteresis is also settable between 0.2ºC to 9.9ºC. The delay time is helpful in increasing the working life of the compressor. This is also available for two compressors ( independnet temperatures and the settings) and three compressors.Temperature Controller with Soak : For heat treatment apipilication addiptional time setting time setting is available to maintain the temperature of the furnace or ovan for the desired set time (0.999min) after the temperature has reached the set value.BOD Controllers : For controller of ovan temperature below or above m ambient temperature. The heating or cooling realy will turn on depending on whether wt temperature is above or below the ambjent temperature. Second sensior for sensing ambient temperature is provided. Both relays have independent hysteresis sellings (by keyboard).Temperature Controller With : The facilitynis used in heat treatment or settable rate of rise of temp material testing equipments .Rate of rise is settable by keyboard from 0 to 10ºC/minProfile Temperature Controller : This is useful in obtaining variable temperature profile in an ovan or furnace for heat curing application. The time and temperature data can be led by the keyboard, control action can be on/off or time propotional. this is also useful for testing purpose in Laboratory (Calibration Bath).PID Temperature Controller (Proportional, Integral & Derivative) : This is useful for precise control of temper ature in an ovan, furnce, plastic machinery etc. when job requires high heating during initial period & low heating when temperature stabilizes. Derivative action overcomes sudden changes in temperature due to load changes, integral action corrects the accumulated error.Derivative time constent and intergal time constant have to be set suitable for the machine whose temperaturemis to be controlled, initially, trial and error methodmis required to select these parameters, but once they are set the action gives better control of temperature.Relay output for control of contractor or pulse output for control of SSR is provided. Optionally 0 - 10V output can also be provided for control of SCR firing units.Controller with Analog Input : This is useful in application where transducers are used (i.e. load cell, flow sensor, pressure sensor etc.) The signal can be ) -10V or 4-20m A D.C. Like in other controllers, single set point and two point models are available. These relays can also be used as alternative settings, Calibration through key board is possible.
Temperature Indicators
Get Price Quote
Sensors, Rf Transmitter, converters, controllers, Temperature Controllers
Temperature Controller
Get Price Quote
Thermocouple
Get Price Quote
Electric Furnace
Thermocouple
Get Price Quote
industrial infrared heaters, electric heating equipment
Temperature Indicator
Get Price Quote
Temperature Indicator, Environmental Monitoring System, INDUSTRIAL PH METER