Operation of Timer based Direct ON Sump pump controller for sump tank and OH tank · Fully automatic water level controller connecting sump tank and over head tank maintaining full OH tank as long as water available in the sump · 1 sensor will be put at OH tank at 90% (High) just below overflow level · 2 more sensors will be put in sump tank at 10 % just above suction head called low and at 20% called high levels · Pump starts in timer mode when water is available above 20% in the sump and OH tank is not Full. Pump runs for the preset ON time OR stops when water reaches Full before preset ON time. · Pump goes to OFF for the preset OFF time · Pump also stops if water falls below low sensor in the sump as preventive dry run protection. · Pump does not start after preset OFF time if water is not above 2 sensors in the sump · Pump will not start if any of the 3 sensor wires is broken · No airlock or dry RUN since pump stops before water falls below suction · It comes with Micro controller Technology, maintenance free magnetic sensors, FR4 doubled sided 1.6mm PCB with green mask and 70 micron thick copper tracks. · 12 months warranty, direct from manufacturer including controller and sensors