Air Cooled Heat Exchangers
Get Price Quote
Air Cooled Heat Exchangers is carried away by the water and glycol coolant mixture. Air conditioning is the process of altering the properties of air primarily temperature and humidity to more favorable conditions.
Hot Air Preheater
Get Price Quote
An air preheater (APH) is general term to describe any device designed to heat air before another process (for example, combustion in a boiler) with the primary objective of increasing the thermal efficiency of the process. They may be used alone or to replace a recuperative heat system or to replace a steam coil. In particular, this article describes the combustion air preheaters used in large boilers found in thermal power stations producing electric power from e.g. fossil fuels, biomasses or waste. The purpose of the air preheater is to recover the heat from the boiler flue gas which increases the thermal efficiency of the boiler by reducing the useful heat lost in the flue gas. As a consequence, the flue gases are also sent to the flue gas stack at a lower temperature, allowing simplified design of the ducting and the flue gas stack. It also allows control over the temperature of gases leaving the stack. Air pre-heater transfer heat from flue gas to air by means of a rotary matrix in which heat is absorbed by the heating elements passing through the hot gas stream & transferred to the combustion air stream.
Best Deals from Heat Exchangers
Pressure Vessel Heat Exchanger
Get Price Quote
PRESSURE VESSELS We Heat Transfer Equipments Pvt ltd extend our global services with design and manufacturing of all types of pressure vessels for the Industries with (or) with out U stamp as required. Below are some of pressure vessels up to 250 bar pressure can be manufactured in Heat Transfer Equipments Pvt Ltd. DESIGN OF HEAT EXCHANGERS AND PRESSURE VESSELS We HTE is ASME (American Society for Mechanical Engineers) approved manufacturers for Heat Exchangers and Pressure vessel, Our products are Designed, Manufactured and Inspected as per the U stamp vessel Consideration. Our Shell and Tube Heat Exchangers Design Process Contains Two Parts - Thermal and Mechanical Design. We are in Design and manufacturing of the heat transfer equipments as per the TEMA (Tubular Exchanger Manufacturers Association) ASTM Section (VIII) (unfired pressure vessels) BS, DIN Standards. And follows IS 2825, IS 6088, IS 4503, codes. We are ASME certified on June 30th 2011 to manufacturer Heat Exchanger in India. ASME - [The American Society of Mechanical Engineers]. We are U Stamp and S Stamp Certified that Authorized for Manufacturer and Assembly of Power Boilers and Pressure Vessel. Click to view larger. 1. Mist Eliminators2. Filter housings3. Air receivers4. Headers5. Storage tanks6. Column7. Vacuum pre concentrator8. Nuclear waste storage tanks9. Economizer coils10. Feed surge drums etc.
Double Pipe Heat Exchanger
Get Price Quote
A double pipe heat exchanger, in its simplest form is just one pipe inside another larger pipe. One fluid flows through the inside pipe and the other flows through the annulus between the two pipes. The wall of the inner pipe is the heat transfer surface. The pipes are usually doubled back multiple times as shown in the diagram at the left, in order to make the overall unit more compact. The term ‘hairpin heat exchanger’ is also used for a heat exchanger of the configuration in the diagram. A hairpin heat exchanger may have only one inside pipe, or it may have multiple inside tubes, but it will always have the doubling back feature shown. Types of Double Pipe Heat Exchangers :- 1. Counter flow2. Parallel Flow Heat Exchanger 1. Counter flow:-The main advantage of a hairpin or double pipe heat exchanger is that it can be operated in a true counter flow pattern, To get More Efficiency, In the mean Time, it will give the highest overall heat transfer coefficient for the double pipe heat exchanger design. 2. Parallel Flow:-Parallel Flow double pipe heat exchangers are focused to handle high pressures and temperatures applications. Also we can Achieve High Log mean Temperature using this. 3. Double Pipe Heat Exchanger Design:- Determination of the heat transfer surface area needed for a double pipe heat exchanger design can be done using the basic heat exchanger equation: Q = UA ΔTlm, where: Q is the rate of heat transfer between the two fluids in the heat exchanger in Btu/hr, U is the overall heat transfer coefficient in BTU/hr-ft2-oF,Remove term: A is the heat transfer surface area in ft2, and ΔTlm is the log mean temperature difference in oF, calculated from the inlet and outlet temperatures of both fluids. These parameters in the basic heat exchanger equation are discussed in ‘and they are used in an example in ‘ After determination of the required heat transfer surface area, the diameter and length of the inner pipe can be selected and then the diameter of the outer pipe. Finally, the length of the straight sections and the number of bends can be selected. Specifications : Some heat exchanger manufacturers advertise the availability of finned tubes in a hairpin or double pipe heat exchanger. These would always be longitudinal fins, rather than the more common radial fins used in a crossflow finned tube heat exchanger. Applications : A primary advantage of a hairpin or double pipe heat exchanger is that it can be operated in a true counterflow pattern, which is the most efficient flow pattern. It will give the highest overall heat transfer coefficient for the double pipe heat exchanger design. Advantages : Double pipe heat exchangers can handle high pressures and temperatures well. When they are operating in true counterflow, they can operate with a temperature cross. The cold side outlet temperature is higher than the hot side outlet temperature.
Marine Heat Exchanger
Get Price Quote
Hitech Equipments range of heat exchanger are marine heat exchanger, industrial heat exchanger and heat exchanger that Marine Heat Exchangerswe present has been designed and developed in adherence with various international quality Marine Heat Exchangersstandards. These have a compact design and style of construction of the plate arrangement, which allows enhanced performance in Marine Heat Exchangers.
Rcc Cooling Tower
Get Price Quote
We are Specialist in the establishment of Reinforced Concrete Cooling Towers. We Do RCC Cooling Towers Design and Construction for both in Cross Flow RCC Cooling Towers and Counter Flow RCC Cooling Towers, With Long life Compare to FRP and Timber Cooling Towers. RCC Towers made of Concrete cell. All Internal Parts are As per Other Cooling Towers. The Performance of Cooling Tower is Pre Determined and Over Designed based on Long Life Approach. Also Our style of construction is Completely User Friendly and Attractive suitable for huge wate flow application plants like RCC Cooling Tower Applications power plants, sugar plants, Cement plants, Boilers and water treatment plants etc., RCC COOLING TOWER DATA We manufacture high quality Induced draft Cooling Tower in RCC Construction also both in Cross Flow and Counter Flow design that require easy maintenance and low recycle cost. As a result our industrial RCC cooling tower is highly demanded by a number of companies. With our hard work we have been able to enlist ourselves among the leading RCC cooling tower manufacturers and exporters in India. Since the structure of Cooling Tower is complete with RCC, the tower life will be more than timber as well as FRP. Available in two designs: Cross Flow design Counter Flow design Capacity of RCC Cooling Tower : The ranges of our RCC Cooling towers are 500 m3/hr to 3000 m3/hr per Cell Applications : Power Plants Sugar Plants Chemicals Plants
air cooled aftercoolers
Get Price Quote
We are dealing in air cooled after cooler to reduce / cool the compressed air temperature to desired level, so the condensation takes place and vaporized moisture and oil in the air gets converted to liquid droplets which further separated by moisture separator.
Tube Heat Exchanger
15,200 Per Piece
tube bundle heat exchangers
Get Price Quote
We are the leading manufacturers of Tube bundle heat exchanger in India and available in a variety of designs and materials of construction. makes three different models of tube bundle heat exchangers Which are designed for either horizontal or vertical use and Water Makers are made up of U tube Heat Exchangers. We manufacture the Cross flow tube bundle heat exchangers are often used in highly fouling environments such as lignite utility boilers.
Double Pipe Heat Exchanger
Get Price Quote
A double pipe heat exchanger is one of the simplest form of Shell and Tube Heat Exchangers. Here, just one pipe inside another larger pipe. To make an Unit very Compact, The Arrangement is made Multiple Times and Continues Serial and Parallel flow. One fluid flows through the inside pipe and the other flows through the annulus between the two pipes. The wall of the inner pipe is the heat transfer surface.This is also called as a hairpin heat exchanger. These are may have only one inside pipe, or it may have multiple inside tubes, but it will always have the doubling back feature shown. In some of the Special Cases the Fins also Used in Tube side.
Plate Fin Heat Exchanger
20,000 - 40,000 Per Piece
1 Piece (MOQ)
Wooden Cooling Tower
Get Price Quote
Based on the leading-edge cooling technology, the Wooden Cooling Tower, which we offer, is manufactured in confirmation to the set industrial standards. We offer the best Wooden Cooling Tower at the best rates. We are a dependable Manufacturer, Supplier and Exporter of Wooden Cooling Tower. Why Our Wooden Cooling Tower? High cooling efficiencyCompatible sparesEasy maintenanceLow noise Timber : All timber is Pine wood and is treated with Chromate Copper Arsenates. All plywood components are treated marine grade water proof plywood. All sections are fully machined prior to treatment. Structural Framing : Structure is bolted and is designed to withstand all operational loads and wind pressure. Hardware : Hardware such as nuts, bolts, washers, ring connectors etc. shall be Hot dip galvanized steel. Internal Fill & Fill Support : Rectangular Fill splash bars are designed to offer maximum splash and wetted surface in such a manner that it permits no dislocation of splash bars and yet allows them to expand or contract with changes in moisture content of wood without cracking, warping or sagging. Splash bars are supported in GRP grid supporters, which are firmly attached to structural girt members. Drift Eliminators : These are made of treated timber planks supported on grooved treated plywood Eliminator frame in herringbone pattern or PVC in Construction. Casing & Air Inlet Louvers : These will be made of corrugated AC Sheet or FRP Sheet. Tower corners are covered by FRP boards. Casing is water tight sealed. Air inlet Louvers are of corrugated AC Sheets or FRP Louvers. Distribution System : Cross flow towers employ a swamped pan distribution. The open pan covering the entire fill area distributes hot water evenly over the fills by means of PVC nozzles. Fan Deck : The fan deck is of FRP OR MS/HDG Construction with Motor frame & Fan Guard. Fans Dynamically balanced Cast Aluminium Alloy / FRP Fan Motor TEFC-IP 55 With EN -8/9 Shaft & Class F insulation.Direct Drive Ccs Timber Cooling Tower
Wire Wound Heat Exchanger
Get Price Quote
Round Cooling Tower
Get Price Quote
Plate Fin Heat Exchanger
Get Price Quote
We are offering Plate fin heat exchanger is one of the most efficient compact heat exchanger. The gaps between constitute a fluid layer. A core is made of a great number of layers. The exchanger can be made of one or more cores. The number of plate and fin layers, the size of the plates and fin, the height of the fin and the type of fin are engineered for optimum performance. The core is assembled (stacked) and typically held together by tack welding a weld rod to the top and bottom layer of the core. The stacked core is then placed within a fixture that exerts force on the individual pieces to keep them in contact. The part is then vacuum brazed in an environmentally-controlled room to ensure high quality and reliability. After brazing the core is typically heat treated or aged in order to increase its strength. Manifold ducting and mounting brackets are then welded in place as required, and any required paint or coating can be added.
Tube Bundle
Get Price Quote
Tube Bundle, Air Cooled Condensers, Air Cooled Heat Exchanger
Marine Heat Exchanger
Get Price Quote
Marine heat exchangers are the most common way to cool a boat's engine, using the lake, river or ocean water in which the boat floats. Since this water may be corrosive, the engine may be cooled by a sealed mixture of distilled water and antifreeze. Heat from the water–antifreeze mixture is then transferred to the ocean (or lake or river) water which flows into a heat exchanger. To protect the marine heat exchanger from corrosive salts, a sacrificial zinc anode is screwed into the heat exchanger. This anode must be periodically replaced as part of regular maintenance. Because the water the boat floats in may be contaminated with floating particles such as wood or other detritus most boats will have a filter (often stainless steel mesh) to remove these particles before they flow through the heat exchanger. This filter must be periodically cleaned or else the flow of water to the heat exchanger will become obstructed and the engine will overheat.
Air Blast Coolers
Get Price Quote
Gireesh airoil heat exchangers have been made to be used in the return line of the hydraulic systems. The cooler element is made from alum-alloy, which is a highly conductive material. The braise welding process of the, gives a high thermic exchange and a good pressure rating. mineral oils, hl, hlp, water-oil emulsion. we recommend that a bypass valve is installed in parallel to the heat exchanger, to protect it during the starting. Make sure there is no obstruction to the air flow. features • these are continuous flat fin and tube heat exchangers having compact and sleek design. • ideal for oil cooling applications where there is a scarcity of water and fir economy of operation. • provided with axial flow fan and motor of requisite capacity together supplied as a completely packaged unit. • standard sizes available from capacities ranging from 500 kcal hr to 10,000 kcal hr. • higher sizes and custom built units can be offered as per customer's requirements. • designs with copper tubes aluminium fins and copper tubes copper fins available. • available for working pressures up to 15 bar and working temperatures up to 150° c.
Brazed Plate Heat Exchangers
Get Price Quote
We Manufacturer and Exporter of all types of Brazed Plate Heat Exchanger (BPHE) in India, Established in the year of 1989. We are a genuine, reliable and durable Cooling Solution for all types of industries in India as well as overseas. Brazed Plate Heat Exchanger Applications Heat-pump Boilers Evaporators Hydraulic oil cooling District heating Thermal power stations Refrigeration Oil coolers Air conditioning Outdoor wood boilers, stoves, furnaces Domestic water heating Solar energy and chiller applications Brazed Plate Heat Exchanger Advantages We provide high quality Compact design Three way design for heat pumps Higher Heat Transfer High corrosion resistance Low investment costs for BPHE Simplify maintenance and repair with BPHE Versions for standard and high pressure operation
Frp Cooling Towers
Get Price Quote
Since years in this domain, we are engaged in manufacturing and offering a wide range of FRP Cooling Towers. Offered towers are manufactured by our skilled professionals using FRP materials and modern techniques. These are mainly used in oil refineries, power plants and petrochemical plants. Our towers have the capacity to withstand adverse impacts of contaminated water from the process industries. Additionally, FRP Cooling Towers are light in weight and hence, convenient for roof installation. Features Excellent functionality Application specific design Energy efficient
Air Cooled Condenser
Get Price Quote
We are leading manufacturers and suppliers, exporters of air cooled condenser in india and the condenser types are Natural Convection,Forced Convection and also manufacture the Water cooled condenser. Coal based and All Thermal power plants, Solar Power Plants, Nuclear power plants, Gas Based Power Plants.
Natural Draft Cooling Tower
Get Price Quote
Features of Natural Draft Cooling Tower No requirement Fan, Motor and PVC fills. Well planned and designing Power saving and Low maintenance Superior Cooling good organization Installed for various type of cooling applications Easy to cleaning and maintenance Environmental Friendly No Mechanical Noise Safety of operation
Heat Exchangers
Get Price Quote
We are Supplier of this product.
Heat Exchanger
Get Price Quote
Dear sirmadam, greetings for the day… we jc equipments pvt ltd take pleasure to introduce ourselves as one of the leading designers, manufacturers & exporting of all kind of cooling towers,heat exchangers pressure vessels columns, storage tanks, air cooled condensers, etc.. In india. Jc equipments pvt ltd started in the year of 1989. We have wide knowledge in this field and we have regular customers throughout the world. We are authorized manufacturers of asme and we have “u, s & r” stamp certification also. We are corporate member of cti, usa. We are a world class manufacturers and we never compromise in quality. We assure our product will be best quality and competitive price. Herewith we have enclosed the product profile for your kind reference. Kindly refer the attachment. Looking forward your valuable enquiry for us to quote our best and competitive offers, with assuring you of our best quality and prompt service at all times.
Plate Heat Exchangers
1 Per -
Ladle Preheater
Get Price Quote
Natural Draft Cooling Tower
Get Price Quote
Dry Cooling Tower
Get Price Quote
Dry Cooling Tower, Plate Type Heat Exchanger, Natural Draft Cooling Tower
Heat Exchanger Unit
500,000 Per Piece
We are offering highlight of our heat exchanger fins are used to increase the effective surface of area of heat exchanger tubing. Finned tubes are used when the heat transfer co efficient on the outside of the tube is appreciably lower than that on the inside. When an extended surface is needed on only one fluid side or when the operating pressure needs to be contained on one fluid side. Owing to the excellent heat transfer ability, these finned tube heat exchangers are highly in demand our product specification: s.no description moc size 1 fin material aluminium, stainless steel, copper, carbon steel 2 tube material stainless steel, galvanized iron, carbon steel, copper 3 tube size as per design requirement fin specifications hot dip galvanized finned tubes: these finned tubes are used where air is corrosive or having more moisture. This gives longer life of finns. Finned tubes with g.i. Finns: these finned tubes are having g.i. Finns which is used for longer life of finns against corrosion. S. S. Finned tubes: s.s. Finned tubes are having s.s. 304 & 316 tubes & finns. These finned tubes are widely used in pharmaceuticals & food industries. These tubes have no corrosion problem & longer life.
Heat Exchangers
Get Price Quote
Heat Exchangers, Cooling Towers, industrial oil coolers, Oil Coolers