Flexible Wires
We are engaged in offering single core and multicore Flexible Wires that conforms to IS: 694 and IEC: 60227. These Flexible Wires feature copper conductor of high purity- electrolytic grade, annealed copper 0.5 sq. mm to 300 sq. mm. providing insulation for all applications and 70deg. 105deg c heat resistant PVC for high ambient temperatures like in panel, flame retardant low smoke-FRLS for high density critical installations, halogen free flame retardant- HFFR for fire prone areas. These Flexible Wires are featured with dual insulation (primary-natural PVC, secondary colored skin PVC insulation) for extra smooth finish. Our Flexible Wires have higher volume resistivity of insulation and better ageing characteristic. These wires are available in red, yellow, blue, black and green colors. Features : TV co-axial : attenuation losses contained to minimum. Double shielding- primary-polyester backed aluminium taped shielding with 100% coverage additional shielding with fine tinned copper braid to ensure high quality reception and transmission of signals. RG- 6891159 Telephone cables : 1 pair to 100pairs, un-armored armored with conductor size 0.4 to 0.9mm annealed tinned copper Hard grade copper for long life and stable properties Staggered lays of twisted pairs Optimum values of capacitance, capacitance unbalance, attenuation, characteristic impedance, etc.
...moreMCB Switches
We are providing MCB Switches that is a multi-protection device offering protection against overloading and short-circuit. These switches are packed with the features of MCB, ELCB and partly of VCCB for effective performance. These MCB Switches are inclusive of by-pass switch to avoid nuisance tripping, 4pole module, din channel mounting and up to 10ka rupturing capacity. Features : Earth leakage (ELCB) Over voltage (VCCB) Ratings Available : 5a to 63ain 30ma, 100ma, 300ma sensitivity
...moreResidual Current Circuit Breakerearth Leakage Circuit Breaker
We are offering rccb elcb (residual current circuit breakerearth leakage circuit breaker). 6a-100a , 2pole 240v4pole 240415vac 50hz,din rail mounting, conforming to is:12640-1:2000& iec 6 1008-1provides ground fault protection by monitoring the leakage of the current to ground. Rccb will trip when ground faults are detected in excess of the gf trip rating of it. The product can also detect and trip when there is a current differential between the live line and neutral line ,and therefore protect people from electric shock. These devices provide gf protection and life protection and are used in series with standard mcbs which provide overload and short circuit protection.the product can be used as a main device providing gf and life protection for several mcb branch devices.rcbo16a-100a ,2pole 240v4pole 240415vac 50hz,din rail mounting, conforming to is:12640-1:2000& iec 6 1008-1 16a-63a ,2pole 240vac 50hz,10ka,din rail mounting, conforming to is:12640-2:2001& iec 6 1009-2-1used for protection against electrical leakage in the circuit of 50hz or 60hz, rated voltage 240v415v. When an electric shock or the residual current of the circuit exceeds the threshold value, the rcbo can cut off the power within the time of 0.1s to protect the personal safety and preventing the equipment from the fault resulted by the residual current against overload and short circuit.
...morePrewired
What makes prewired so special is the inherent idea behind the product. That it is a product to revolutionize the way distribution boards are judged is important.designed with the user in mind : prewired addresses almost all the weaknesses of the ordinary dblook at the comparison below to check out for yourselfearthing : uniform grounding with specialized terminalsunlike the stud earthing in dbspecified torque : assembling at site as in the case of db does not allow torque application to the optimum leaving scope for fire hazards whereas in prewired specified torque at factory makes it standard and safe.genuine material : carefully monitored and procured materialgoing through stringent checks make prewired meeting all safety parameters which can not be said about the ordinary dbcolour coding : proper colour coding is vital for electrical connections made. In prewired it is done at the factory but in ordinary db it is ignored since it is done at site
...morePre-Wired Distribution Boards
Adhunik Switch Gears Private Limited is one of the successful Manufacturers, Exporters, and Suppliers of Pre-Wired Distribution Boards. Our Pre-Wired Distribution Board addresses almost all the weaknesses of the ordinary DB.Features Earthing : Uniform grounding with specialized terminals unlike the stud earthing in DB Specified Torque : Assembling at site as in the case of DB does not allow torque application to the optimum leaving scope for fire hazards whereas in prewired specified torque at factory makes it standard and safe. Genuine Material : Carefully monitored and procured material going through stringent checks make prewired meeting all safety parameters which can not be said about the ordinary DB Colour Coding : Proper color coding is vital for electrical connections made. In prewired it is done at the factory but in ordinary DB it is ignored since it is done at site.
...morePower Distribution Board
Adhunik Switch Gears Private Limited is recognized as a dependable Manufacturer, Exporter, and Supplier of Power Distribution Board. Our Power Distribution Board is made with the finest Circa Steel sheet that adds to its strength and finishing. The product is subjected to seven tank process to ensure anti rusting and smooth surface. Our Power Distribution Board is coated with polyester resin based powder paint for scratch proof surface.Features Designed to match the styling of your home decor. Proper earthing by means of additional earth bar Makes it completely shock proof, and protection against corrosive atmosphere. Key holes for mounting or hanging the distribution board detachable gland plate at the bottom with knock outs. For maintenance or repairs the front plate is removable, which keeps the plastering intact. Can be used as surface as well as flush mounting.
...moreMolded Meter Boards
The variety of Molded Meter Boards that we are offering is fully installed and manufactured from recyclable special grade fire retardant engineering plastic making it completely shock proof and fire proof. These Molded Meter Boards are fitted with neoprene rubber profiles on the doors making it water proof. Our Molded Meter Boards are fitted with inside hinges making it tamper proof. Having arrangement to operate the MCB without opening the MCB chamber, these Molded Meter Boards are endowed with independency. Molded Meter Boards feature additional pad locking facility for MCB operative window.
...moreMiniature Circuit Breaker
The circuit breaker must detect a fault condition; in low voltage circuit breakers this is usually done within the breaker enclosure. once a fault is detected, contacts within the circuit breaker must open to interrupt the circuit; some mechanically stored energy (using something such as springs or compressed air) contained within the breaker is used to separate the contacts, although some of the energy required may be obtained from the fault current itself. Small circuit breakers may be manually operated; larger units have solenoids to trip the mechanism, and electric motors to restore energy to the springs. At adhunik basics of the all the devices are very strong and unique. Body is made of “polybutaline terapythalate polyesterpolymer chip ”which has highly desirable thermal & electrical properties such as fire get extinguished when it moves from one molecule to another in such kind of material. “action is look like of fire proof materials” making breaking fixed and moving contact- moving- brass plate inlayed by pure silver making room for electrons to flow in a large area with minimum resilience. Fixed contact specially designed to make sure that there is no air gap between the two contacts even after large no of operations, make brake is perfect ,no secondary arc can develop - “action is a weld free mechanism” a common problem with many other designs arc chute tri coating (once with zinc twice with nickel gold) on arc splinters creates a suction effect quenching arc much faster than other mcbs -“action is a safe mcb”. mcb capacity includes 2amp to 63amp and also includes b & c series, sp, spn, dp, tp & tpn.
...moreMCCB Switches
MCCB Switches that we offer conform to IS: 13947-1, 2 & IEC 60947-1&2 with 10ka to 65ka breaking capacity also complying with IEC 68-2-6 vibration test and IEC 68-2-27 shock test, IEC 60529-ip degree of protection, IEC 62262-ik degree of protection against mechanical impact. Models of MCCB Switches are available with source changeover system (main source and alternate source), communication option and optimized auxiliaries. We offer different frame sizes as per suitability of installation, thermal magnetic electronic and microprocessor trip units-as per suitability of application, power supply can be connected from top or bottom reverse feeding in selected models. Short circuit current is limited to very low values due to reflex tripping feature. In case of fault occurrence only the circuit breaker immediately upstream from the fault will trip, due to limited breaking capacity of these MCCB Switches. This discrimination feature allows cascading among number of MCCB installed, thereby upstream circuit breaker protect all circuit breakers placed downstream as well as other feeders will remain active in case of fault occurrence in one of output feeders. Salient Features : 0a-1250a, 2pole, 3pole, 4pole with configuration240415vac50hz Clear on-off trip indications, high electrical and mechanical endurances, line load reversibility, push to trip facility, terminal suitable for al & cu, phase barriers as standard, field fitted accessories Add on features : front face and centralized overload adjustment, extended rotary handle and door interlock with ip-54 protection, spreaders provided as standard wherever necessary rom, shunt obligery contract, spreaders & extended terminal links.
...moreLuminaire Lights
We are involved in offering a wide variety of Luminaire Lights. Our Luminaire Lights are exclusively designed by keeping in consideration the modern designs. These are included with special flexible clamps for mounting in different conditions. Our Luminaire Lights feature channel made up of special high grade fire retardant PVC, lamp holder made of white poly carbonate, phosphor bronze contacts and push-fit arrangement. The end caps of these Luminaire Lights are made of high grade abs along with special dual prismatic cover for anti-glare effect. We also provide LED luminaries with electronic and conventional ballasts. Features : T-5 luminaries 0.9> pf >0.9 and thd less than 30%, 20%, 10% Operating voltage 80v ac to 300 v ac Available in 1428 for t-5 & 1836 watts for t-8
...moreLT Panel
We are offering LT Panel of 415v 50Hz with 3phase and 4 wire system. Our LT Panel is CPRI tested for 4000a rated current and short circuits withstand strength 50ka conforming to IS: 862393 degree of protection IP-42 to IP-56 as per application and requirement. This LT Panel is fabricated by special 79 tank process sequenced as de-greasing, rinsing, de-rusting, rinsing, phosphatising, rising and passivation followed by oven heated powder coat with a paint thickness of 60 microns and above. Our LT Panel is unique and provides extraordinary smooth surface in all the panels making them very attractive in appearance and extraordinary in performance. Compartmentalized structure of this panel ensures complete operator safety. All the compartments including bus chamber, cable alley and connector compartment are dust and vermin proof. High grade copper bus bars are joint-free and fully insulated with internationally color coded plastic sleeves supported on non-hygroscopic, noncombustible, anti-tracking, and F-class insulators. Load bearing members are not less than 2.0mm thick. It features a modular design with user-friendly operation and extensible on both sides change. Feeder and cable alley doors open in different directions providing ample space for working. In Draw Out Modules : Similar sized modules are interchangeable Electrical indications available for different positions such as test service isolation. User-friendly operating handle of the highest unit is not more than 1.7mt. overall height not exceeding 2.7mt. Removable gland plate provided for each cable entry
...moreCirca Steel Sheet
We are offering circa steel sheet. Fabricated using the finest circa steel sheet for lasting strength and fine finishing.subjected to seven tank process to ensure anti rusting and smooth surfacecoated with polyester resin based powder paint for scratch proof surface.designed to match the styling of your home decor.proper earthing by means of additional earth barmakes it completely shock proof, and protection against corrosive atmosphere.key holes for mounting or hanging the d. B.detachable gland plate at the bottom with knock outs.for maintenance or repairs the front plate is removable, which keeps the plastering intact.can be used as surface as well as flush mounting.
...morepre wired distribution boards
Be first to Rate
Rate ThisOpening Hours