Aqology Teknix Gangotri Enclave, Delhi

GST Number : 07AAQFA8322B1ZN
Contact Supplier Request A Quote
  • zero liquid discharge system

    zero liquid discharge system

    Request for Price

    Type : Zero Liquid

    Voltage : 220V

    Automatic Grade : Automatic

    Power : 1-3kw

    Driven Type : Electric

    Weight : 100-1000kg

    ...more
    Get Best Price
  • Water Purifier RO SYSTEM

    Water Purifier RO SYSTEM

    Request for Price

    We offer systems with pressure upto 120 bar, so as to obtain a higher recovery than with conventional spiral wound construction. Also, this construction works well with higher turbidity & biological impurities and is easier to maintain.

    Application : RO Industry

    Voltage : 220V

    Automatic Grade : Automatic

    Power : 1-3kw

    Driven Type : Electric

    Industrial R O System : 1000-2000kg

    ...more
    Get Best Price
  • UV Germicidal Irradiation System

    UV Germicidal Irradiation System

    Request for Price

    For energy saving and improvement in Indoor Air Quality in Air Handling Units. Contaminated air passing through the cooling coil deteriorates the indoor air quality. Condensation of moisture around the cooling coils leads to growth of bacteria, viruses and other forms of microbes, reducing the heat transfer efficiency & air flow in the AHU--thereby increasing the power consumption. Ultraviolet light penetrates cell walls of microbes, damaging their DNA structure so that they cannot grow, thus keeping cooling coil clean on continuous basis and saving power and protecting air quality. 10-15% Power Saving Destroys airborne microbes Improvement in IAQ (Indoor Air Quality) Enhanced Cooling Coil & HEPA Filter Life Reduced Maintenance & Downtime Minimizes physical cleaning, pollution caused by cleaning agents and water wastage, and associated costs.

    Body Material : Mild Steel

    Power : 0-3 Kw

    Power Source : Electric

    Industrial Use : Industrial

    Voltage : 220

    Control Type : Automatic

    cleaning system : RO

    tank type : Horizontal, Vertical

    ...more
    Get Best Price
  • Suspended Solids Filtration System

    Suspended Solids Filtration System

    Request for Price

    In circulating cooling water : Induced air brings in with it suspended matter continuously and its concentration in circulating water keeps rising. Its deposits on condenser tubes/plates and cooling tower internals cause a rise in compressor power consumption. By keeping the heat transfer surfaces clean from suspended matter, the filter ensures that compressor power consumption doesn't go up. Kindly see the attached note and our current client list.     In circulating chilled water : Corrosion products, scale, and algae deposit on heat transfer surfaces of cooling coil, reactor and affect the heat transfer efficiency. Chilled water flow has to be increased to get the temperatures required-raising the power consumption. Filtration also minimizes erosion by corrosion products, maintenance, water treatment chemicals consumption, and blowdown of costly chilled water.      Israeli technology - Fully automatic, zero maintenance, negligible water consumption. Installations are already in 23 Indian States.  

    Material : Metal

    Shape : Round

    Packaging Type : Corrugated Box

    Pore Size : 0.22

    Filter Length : 2 Inch, 5 Inch, 8 Inch

    Filtration Capacity : 10 Microns, 20 Microns, 30 Microns

    Usage : Water Filter

    ...more
    Get Best Price
  • Multiple Effect Evaporator System

    Multiple Effect Evaporator System

    Request for Price

    To treat RO reject. Better Steam to Evaporation Ratio with lesser maintenance/fouling/choking of tubes.  

    Material : Stainless Steel

    Application : Industrial

    Feature : High Grade Material, Low Maintenance, Rust Proof

    Voltage : 220V

    Finishing : Polished

    Automatic Grade : Fully Automatic

    Phase : Tripple Phase

    ...more
    Get Best Price
  • Industrial Heat Pumps

    Industrial Heat Pumps

    20,000,000 Per Piece

    Custom engineered systems for generating hot water at a low cost. With COP of the order of 3, input energy (Power/fuel) required is only a fraction of the conventionally consumed energy. Systems can be offered for generating hot water up to 120deg C, a unique feature.

    Type : Industrial Pump

    Material : Stainless Steel

    Voltage : 220V

    Power : 100-500W

    Driven Type : Automatic

    Pressure : High Pressure, Low Pressure, Medium Pressure

    ...more
    Get Best Price
  • Energy Efficient Chiller System

    Energy Efficient Chiller System

    Request for Price

    ROI Benefits through Continuous Condition Monitoring:   Operational Benefits: By detecting any failure early in its cycle, it can help you achieve the following operational benefits Higher Equipment Uptime  Longer Mean-time between maintenance (MTBM) Enhanced component lifetime Higher Equipment availability  By monitoring the condition of your equipment, you can operate the machines until required maintenance instead of scheduled maintenance, thereby directly helping your organization achieve the maximum output (production) from your production lines by giving you the best operational equipment efficiency (OEE)      Maintenance Benefits: By helping you move to predictive maintenance, our product can help you achieve the following maintenance benefits Targeted maintenance Short Mean Time To Repair (MTTR) No cascading damage to other components It will help you target the maintenance activities towards the root causes of failures and therefore directly help you reduce the MTTR. In addition, as you will be able to detect and act upon the upcoming failures, you will be able to avoid the extended damages which one component causes to the other upon failure, thereby not only saving you cost but also reducing equipment downtime. These benefits will directly help your organization lower maintenance costs and increase output from your production lines       Safety & Risk Avoidance:  Easy real-time access to non-accessible equipment - which directly improves safety at your workplace Risk avoidance - By correcting failures right at the start and ensuring high OEE, you will avoid the risk of business loss through downtime (can be directly calculated by the time lost multiplied by the cost of loss in production, manpower, and spare parts)      Salient Features: Here are a few salient features that make it stand out compared to the competition: Cost-Effective: Compared to the other tri-axial equipment in the market, our tri-axial (horizontal, vertical, and axial) sensor costs 5-6 times lower Auto Diagnostics Feature: It is the only one in the market which has an in-built diagnostics feature - which means that the sensor not only analyses the vibration pattern but also detects the source of the vibration and helps you take relevant corrective actions to eliminate it. The best part is that you do not need any additional software to access the diagnostics feature - you get all these benefits built right into your dashboard! Cloud Connectivity: Its sensors connect to the cloud via Wi-Fi and give you real-time analysis, diagnostics, and prognosis on your dashboard, which you can access from a computer or a mobile phone anywhere in the world! Alarms: You can set multiple alarms for your equipment for any parameter. Whenever there is any breach in any parameter, you will be alerted through an SMS or mail   Plug & Play: It can be up and running on your equipment within 1 minute! You can opt for various mounting mechanisms like (i) magnetic mounting and (ii) magnetic + stud mounting Temperature: It not only monitors the vibrations but also monitors the temperature of the equipment to detect problems (eg improper meshing, amount of greasing low, etc) before they start to magnify and damage the equipment Acoustics: Another stellar feature is that it has in-built acoustics monitoring to detect issues before they start to magnify and damage the equipment  Signal Energy: It helps to detect issues related to bearings in your equipment early on and help you take corrective action Integration with PLC / SCADA: With the help of the RS485 communication module, it can easily integrate with your PLC / SCADA systems and help you trip your equipment / generate alarms basis any of the vibration, temperature & acoustics readings from the sensor Report generation: Its dashboard gives you access to historical and current reports as per your requirement in an excel format Remaining Life Analysis (RLA): It can detect the remaining serviceable life of a bearing and can help you undertake predictive maintenance, thereby helping you get the maximum out of the installed equipment We have attached a detailed presentation and a few case studies with the mail below for you to get a feel of what it can do for you.   We would be glad to help you improve the uptime of your critical equipment and get the maximum return for your investment through a POC (Proof of Concept) Trial at your facility. For the first system, you will pay only once the performance is proved.   Assuring you of our best services at all times.  

    Material : Stainless Steel

    Finishing : Polished

    Overall Length : 35mm, 45mm

    Usage : Water Cooling, Air Cooling, Oil Cooling

    Specialities : Rust Proof, Long Life, High Performance

    Cooling Capacity : 10-50Ltr/h

    ...more
    Get Best Price
  • Electronically Commutated Blower

    Electronically Commutated Blower

    Request for Price

    Latest 5th generation technology which provides reduction of the order of 40% in energy consumption. Maintenance Free, designed with HQ bearings so the bearing maintenance is nil, modulation through an in-built controller hence no need of additional VFD, designed to withstand a highly corrosive environment.

    Application : Industrial

    Voltage : 220V

    Automatic Grade : Semi-Automatic

    Power : 1-3kw

    Driven Type : Electric

    ...more
    Get Best Price
  • Electrolysis Based Water Treatment System

    Electrolysis Based Water Treatment System

    Request for Price

    Takes care of scaling, biofouling, algae, corrosion without chemicals. Virtually nil downtime.

    Capacity : 1000-10000L

    Body Material : Stainless Steel

    Power Source : Electric

    Industrial Use : Industrial

    Voltage : 220

    Control Type : Automatic

    ...more
    Get Best Price
  • Cooling Tower Fan

    Cooling Tower Fan

    Request for Price

    We are now also offering Cooling Tower Fans which have been giving more than 20% power savings in >600 plants in India and in 33 other countries. Kindly see the attached ppt for information about the technology and the company.    

    Usage/Application : Air Conditioning

    Color : Silver

    Country of Origin : India

    ...more
    Get Best Price
  • Automatic Tube Cleaning System

    Automatic Tube Cleaning System

    300,000 - 5,000,000 Per Numbers

    We are offering automatic tube cleaning system (atcs). deposits occur on condensers of water cooled chillers, and other heat exchangers. These cause power loss, downtime, long-term wear & tear, maintenance cost--even capacity-loss. atcs keeps the condenser tubes clean automatically and on-line--without having to take the equipment out of service.

    Type : Condenser Tubes

    Material : Mild Steel

    Application : Industrial Use

    Weight : 100-1000kg

    Voltage : 380V

    Condition : New

    Power : 1-2kw

    Warranty : 1year

    Country of Origin : India

    Brand Name : Whirler

    Country of Origin : Made in India

    ...more
    Get Best Price
  • condenser tube cleaning system

    condenser tube cleaning system

    Request for Price

    For keeping heat exchanger clean from scaling/fouling. Industrial chilling and air-conditioning are most of the time the biggest power guzzlers in process industry & centrally cooled buildings such as hotels, hospitals, malls, office buildings. And within, chillers consume the most. Chiller compressors would easily be consuming more than 1/3rd of the total in the plants/premises. This equipment keeps Chiller Efficiency at peak all along.   On-line automatic removal of scale from condenser : The scale that deposits on condenser tubes continuously causes a rise in compressor power consumption. The automatic Tube Cleaning System keeps the tube clean from scale and has a unique, pump-less design. Reduces power consumption, downtime & maintenance.   Some Features : Saves 10-25% Compressor Power Eliminates Need of Chemical & Manual Cleaning No Dip in Cooling Throughput During Cleaning Protects Condenser Life Common System for Multiple Chillers, Saving Initial Cost No Wearing Parts The Automatic Condenser Tube Cleaning System introduced by us is saving several plants substantial power. Now we bring you the option which is most economic, both in Capital Cost and Operating Cost.    The proprietary pump-less design saves:  power,  space & maintenance                          You can view the working principle on the youtube link: https://youtu.be/2kXluUxShxQ      If you opt for a pump-based system, we have that too in range and its price will be the same.   The Hallmark of performance is repeat clientele across the country, including industry leaders such as L&T Infotech, TCS, Dr Reddy's Labs and many more.   It is working on chillers of all leading makes.  THE WHIRLER™ Benefits :       Use the  WHIRLER™ Forget  Cindenser  DE-SCALING!   Fully automatic system! Keeps the condenser cleaned all the time!   Reduce your energy consumption up to 30 %.    Enhance condenser tube life by eliminating/reducing condenser descaling!   Please let us have the following data, soon after receipt of these we will send you our offer and estimated payback period calculations :   Chiller Rating (TR) Number of Chillers in a common room Condenser Inlet & Outlet Size Power Tariff IkW/TR

    Voltage : 220-240 V

    Phase : Single Phase

    ...more
    Get Best Price
  • Automatic Backflush Side Stream Filter

    Automatic Backflush Side Stream Filter

    Request for Price

    Working Principle:- Pressurized water enters the filter Inlet (1) and travels through Fine Screen (2)where suspended particles are filtered. Clean water then exits the filter through Outlet (12). As particles deposit on the screen, pressure drop across the screen increases, and is continuously sensed by Differential Pressure Indicator (10). When it reaches 0.5 bar, the Electric Control Unit (3) triggers the Solenoid Valve (11) to open the Hydraulic Flushing Valve (4) and the upper, Hydraulic Motor Chamber (6) gets exposed to atmospheric pressure. With the lower chamber being at line pressure, water escapes from it to the upper chamber through the Dirt Collector (7). For this, water is sucked by Suction Nozzles (8) which dislodge & suck dirt deposited on the inside surface of screen. As water passes through the Hydraulic Motor (9), it gives the suction nozzle assembly rotary motion (like sprinklers in lawn irrigation). Simultaneously the Hydraulic Piston (5) raises the suction assembly. With these two motions together, nozzles clean the whole periphery & height of the screen. The flush water flows through the dirt collector and out to the flushing valve to atmosphere. After a preset time, the flushing valve closes and the cleaning cycle is complete. Dirt collector then settles down by gravity.   The entire cleaning cycle takes approximately 15 seconds.  Even during the back-flush cycle, filtering continues interrupted.   Benefits of Circulating Cooling Water On-line Filtration:  Following are various effects of TSS build up in circulating cooling water. Many of them would apply to you: • Power consumption: o chiller compressor power consumption goes up due to fouling/scaling of condenser and cooling tower internals o deposits in piping cause restriction to flow, causing more pumping power for maintaining same flow o reduced heat transfer efficiency in heat exchangers/reactors/condensers necessitates increase in cooling water flow rate, for evacuating same amount of heat, consequently more pumping power. • Production loss: o Reduced throughput in reactors/process-condensers, due to slowed down cooling o Downtime for removal of scale from condenser/heat exchanger/reactor and Cooling Tower internals   • Maintenance cost: o Cost of manpower o Cost of descaling chemicals o Replacement of cooling tower fills & nozzles o There are even instances of collapse of film fill assembly, due to increased dead weight   • Water consumption: o CoC can be increased by keeping cooling water clean from suspended solids   • Water treatment chemicals' consumption: o Goes up with rise in turbidity of cooling water, for maintaining the chemicals' efficacy   • Others: Corrosion due to scaling and bacteria finding shelter between scale & tube surface (known as under-deposit corrosion), reducing life of tubes o Every time chemical descaling is done, some parent material is eaten away, reducing life of tubes o Increased rate of erosion of pump seals & valve seats o Erosion also happens due to continuous bombardment of suspended matter carrying abrasive content o Particles may also scratch away metal-oxide or other protective films o Suspended matter provides surface for microbial growth, which is carried with humid & hot discharge air. It can spread contamination in neighborhood as heavy air descends-- causing health hazard (there have been casualties abroad caused by this phenomenon called Legionella) o Organic suspended matter causes growth of biofilm & slime which also leads to corrosion and insulation of heat exchange surfaces. On-line Cooling Water Filter of innovative design is a small-in-cost, big-in-benefits solution for these problems, already working in 17 states of   India.      

    Application : Filtration of Suspended Solids from Cooling Tower Water, Raw Water, Effluent ,Treated Water

    Filter Type : Self Cleaning Screen Filter

    Type Of Machines : Automatic Backflush

    ...more
    Get Best Price
  • Articmaster Condenser

    Articmaster Condenser

    Request for Price

    It improves efficiency in HVAC and saves energy by a minimum of 20% in Air-cooled condensers and 10% in Water-cooled condensers, average annualized. Kindly see attached Catalog. Total savings in power with the implementation of the above could be well above 25%. Besides, there will be a substantial reduction in downtime & maintenance.    Further, we also bring you the following energy/water / environment-saving technologies

    Type : Condensers

    Weight : 100-1000kg

    Power : 1-2kw

    Warranty : 1year

    Material : Mild Steel

    Application : Industrial Use

    Voltage : 220V

    ...more
    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Exporters / Wholesale Suppliers
  • Year of Establishment 1990
  • No. of Employees 11
  • Annual Turnover Rs. 5 to 25 Crore Approx.
  • Ownership Type Partnership
  • GSTIN Number 07AAQFA8322B1ZN

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Promoting NEW technologies in Cooling Tower and other Water treatment--maintenance free, energy saving, chemical free.
Read More »

Contact Information

Aqology Teknix

  • Mr. Ajai Agarwal
  • C-40-A, Alaknanda, Gangotri Enclave, Delhi
top