Wilo Supreme pump
Self priming mini monobloc Application Water transfer in: Bungalows Farm houses Apartments Solar heater systems Lifting water to over head storage Lawn sprinklers Car washing Ornamental fountains Special features / product benefits Compact design with handle to carry Technical data Flow: upto 38 LPM Head: upto 36 mts Power: upto 0.37 kW (1HP) Pipe Size: 25 mm Volt: 160v to 250 v
...moreWilo Return Line Temperature Controller
Wilo RLTC is used for instant hot water at taps and showers. It is specially designed for apartments, hotels, resorts and commercial establishments. Application Hot water circulator pump controller Special features / product benefits Temperature controller with 7 Segment digital display and keys Thermocouple/RTD (PT100) Sensor Programmable Real time digital timer with LCD display Technical data Wall Mounted IP 54 ABS Enclosures Input Power Supply 230VAC±10%, 50Hz 5A Out Put Power Supply SPDT 230VAC, 10A resistive Ambient Temperature 0 to 40°C Relative Humidity 95% non-condensing Auto-0ff-Manual Switch
...moreWilo DTC pump
Wilo DTC is specially designed for automatic control of hot water circulation in solar application. It controls the circulation of hot water in solar system by switching ON and OFF of the pump based on the difference of the temperature between the solar collector and the storage tank. Application Hot water circulator pump Special features / product benefits Wall Mounted IP 54 ABS Enclosures Out Put Power Supply SPDT 230VAC, 10A max resistive Relative Humidity 85% non-condensing Auto-0ff-Manual Switch Differential Temperature controller with 7 Segment digital display and keys Two Thermocouple/NTC Sensors Programmable Real time digital timer with LCD display (only in advanced version) Technical data Input Power Supply 230VAC±10%, 50Hz Ambient Temperature 0 to 40°
...moreWastewater pump
Design End suction top discharge Mounting: Horizontal Stage: Single Casing with hand hole inspection cover mechanical seal/ gland packing large free passage up to 200 mm Grease lubricated antifriction bearing Application Municipal raw sewage transfer Sewage treatment plants Effluent treatment plants Dirty water in industry Sugar mills Special features / product benefits Mounting: Vertical Delivery flange orientation change possible Bush bearing Technical data Qmax: 8000 m3/hr Hmax: 70 m Temperature: up to 70°C Delivery Size: DN 50 – DN 800
...moreVR HVAC Controller
Variable speed Pump Control unit for HVAC System. Wilo-Mather and Platt Pumps Limited, VR HVAC Controller is specially designed for automatic control of pumps in heating, ventilation and air conditioning applications. The VR HVAC controller is used along with variable frequency drives and differential transmitter to control the differential pressure in a system as a function of the load. VR HAVC controller offers a simplified control and ease of operation. The VR HVAC Controller operates the pumps to meet the changing system demand received by the sensors by varying the speed of the pumps to meet the system requirements and resulting in energy saving operation. Application HVAC Controller Special features / product benefits Encl with or without provision for VFD Communication ports to receive data from Variable frequency drive Technical data Wall Mounted/Floor Mounted Enclosure. Internal Circuit breaker with door interlock. System can control 1-4 pumps max. Automatic pump alteration. Duty and standby selection of the pump. Microprocessor based pump logic controller with built in PID Control Modes Delta PC and Delta PV Embedded logic to prevent pump hunting, pump flow surges and motor overheating LCD with Back-lit Display On screen menu driven functions with rotary switch Emergency operation mode Password protection for security Alarm and fault data login Common failure and operation relays Remote start/stop mode Analogue inputs for Remote set point Each Pump operational data Size (in mm) : 500 h x 500 w x 250 d Approximate Weight : 30Kgs
...moreVertical Turbine Pump
Vertical wet pit Stages: Single / multistage Closed impeller Above or below floor discharge Pumped medium lubricated line shaft bearings Non pull out bowl/ rotating element Antifriction bearings Application Water supply/ irrigation Cooling water for power plant Flood control/ condensate extraction general industry/ fire fighting Special features / product benefits Caission/ cannister construction Tilted pad thrust bearings with cooling arrangement, semi-open impellers Oil / external water lubricated line shaft bearings Pull out rotating element, instrumentation & controls Technical data Qmax : 50000 m3 /hr max Hmax: 450 m Temperature: up to 800 C – higher on request Delivery Size: DN 100 – DN 2000
...moreVertical Sump Pump
Vertical wet pit volute pump with Dry motor Stage: Single Closed impeller Oil lubricated bearing arrangement antifriction bearing Mechanical seal/ gland packing Application Emergency oil pump Dewatering Special features / product benefits Technical data Qmax: 750 m3/hr Hmax: 220 m Temperature: up to 80°C Delivery Size: DN 32 – DN 200
...moreTwin Booster Pump
90,000 - 100,000 Per Piece
Type : Booster Pump
Application : Industrial
Weight : 10-20kg, 20-300kg, 30-40kg, 40-50kg
Voltage : 110V, 220V, 380V, 440V
Power : 10hp, 1hp, 2hp, 3hp, 5hp, 7hp
Driven Type : Electric, Hydraulic
Pressure : High Pressure, Low Pressure, Medium Pressure
Warranty : 1year, 2years
...moreSubmersible Sewage Pump
Design Submersible sewage pump with internal macerator for intermittent operation with grey cast iron hydraulics and stainless steel motor for stationary and portable wet well installation. Application Pumping sewage containing faeces as well as municipal and industrial sewage, also with long-fibre constituents in Pressure drainage House drainage Sewage disposal Water management Environmental and water treatment technology Special features / product benefits Internal macerator Low weight thanks to stainless steel motor Explosion protection as standard Technical data Flow: upto 16 m3/hr Head: up 39 m Mains connection: 3~400 V, 50 Hz Submerged operating mode: S1 Non-immersed operating mode: S2-8 min; S3 25% Protection class: IP 68 Insulation class: F Fluid temperature: 3…40 °C Max. submersion depth: 10 m Cable length: 10 m
...moreSubmersible Polder Pump
Mains connection 3~400 V, 50 Hz Max. fluid temperature 20°C Min. flow at outside shroud not necessary. Up to 10 starts per hour Max. immersion depth 300 m Protection class IP 68 control range for frequency converter 2-pole: 25-50 Hz 4-pole: 30-50 Hz Application Potable and process water from tanks or shallow bodies of water; municipal and industrial water supply; sprinkling and irrigation; lowering the water level; utilisation of geothermal energy and offshore applications Special features / product benefits Technical data Qmax: 1200 m3/hr Hmax: 160 m
...moreSubmersible dewatering
Submersible dewatering Application Dewatering from residential buildings Commercial buildings Industry Hospitals Special features / product benefits Stationary and portable Technical data Flow: upto 1000 LPM Head: upto 30 mts Solid passage: upto 16 mm
...moreSubmersible Dewatering Pump
Vertical submersible dewatering pumps Stage: Single Free flow impeller free passage size up to 45 mm Double mechanical seal Oil barrier chamber with float switch winding temperature indicators moisture sensor Application Dewatering dirty water containing sand Construction sites Fountains Special features / product benefits Stationary / portable installation Level sensor for single phase versions with/ without ceram coating for aggressive liquids Technical data Qmax: 340 m3 /hr Hmax: 68 m Temperature: up to 40°C Delivery Size: DN 32 – DN 150
...moreSubmersible Booster Pump
Application Pumping from: Well Sump Special features / product benefits Compact design Supplied along with control panel Technical data Flow: upto 266 LPM Head: upto 88 mts
...moreStar Rs Hot Water Circulation Pump
Specially designed for hot water circulation Application Hot water circulation in solar system, heat pumps system and other systems Hot water circulation in industrial use Cold water systems and air conditioning system Special features / product benefits Compact design Technical data Flow: 90 m /hr Head: 7.5 m
...moreStandard Horizontal Split Case Pump
Design Mounting: Inline horizontal Stages : Single/ double, single/ double suction Impellers shaft with sleeves Grease lubricated anti-friction bearing Mechanical seal/ gland packing Application Water supply / general industry Building service / fire fighting Spray irrigation / district heating Special features / product benefits Mounting: Vertical Technical data Qmax: m3/hr max 3400 Hmax: 235 m Temperature: up to 120°C; Higher on request Delivery Size: DN 50 – DN 400
...moreSolid Separation Systems
Design Sewage lifting unit with solids separation system for installation in a building or concrete sump Application System for installation in an existing structure (building or concrete sump). Sewage lifting unit with solids separation system for drainage of large residential estates and boroughs or as a replacement system for the refurbishment of existing large concrete sumps. Special features / product benefits Energy saving due to pumps with narrow ball passage, which produces better efficiency than with conventional sewage pumping stations Considerably less susceptible to plugging as the pumps do not come into contact with the solids in the wastewater Uninterrupted operation during maintenance or repair work due to the station’s double-pump design and individual shut-off of the solids separation reservoirs All parts are accessible from outside, so very easy to maintain and hygienic Resistance to corrosion and long life due to construction from PE-HD material Technical data Max. inlet: 600 m3/h Max. useable tank volume: 12000 L Max. delivery head: 80 m Installation depth below inlet floor: 1200 – 2300 mm Mains connection: 3~400 V, 50 Hz
...moreSelf Priming Monoblock Pump
Application Water transfer in: Bungalows Farm houses Apartments Special features / product benefits Compact design Technical data Flow: upto 52 LPM Head: upto 45 mts Power: upto 0.75 kW (1HP) Pipe Size: 25 mm Volt: 230 v
...morePressure Boosting System
Water up to the top floor More comfort with intelligent technology: Where the minimum water pressure from the public water works is not sufficient, a pressure boosting system helps with optimal water supply. Individual Wilo solutions for optimal water pressure Especially for the historical residential areas or in the case of floor expansions, the pressure above and directly below water reservoirs cannot be maintained. Therefore, a pressure boosting system might also be required in multi-family homes, apartments, townships and high rise buildings. Wilo offers you individual solutions here.
...moreOpenwell Submersible Pump
We are the main supplier of this product.
Type : Submersible Pumps
Application : Industrial
Voltage : 110V, 220V, 380V, 440V
Fuel : Diesel, Electric
Automatic Grade : Automatic, Fully Automatic, Manual, Semi Automatic
Power : 1-3kw, 3-5kw, 5-7kw, 7-9kw, 9-12kw
Pressure : High Pressure, Low Pressure, Medium Pressure
Warrenty : 1 Year, 2 Years
...moreNon Clog Pump
Non clog pump Application Application: De-watering from trenches and pits Sewage pumping Special features / product benefits Compact design Available in options like motor driven/engine driven Technical data Head: 6 – 34 mts Flow: 60 – 4446 LPM
...moreNolta Level Regulator
Type : Hydraulic Regulators
Material : Aluminium, Fiberglass, Glass, Porcelain
Application : Electricity Controlling
Color : Creamy, Green, Metallic, Shiny Silver, Sky Blue
Condition : New, Old
Automatic Grade : Manual, Semi Automatic
Pressure : 10-20psi, 20-30psi, 20-40psi, 50-60psi, 70-80psi, 90-100psi
Feature : Accurate Reading, High Performance, Lightweight Specifications
...moreMultistage Ring Section Pump
Mounting: Horizontal Stages: 3 to 15 Radial flow impellers with vane diffusers mechanical seal/ gland packing Grease lubricated antifriction bearings Application Mine dewatering Descaling in steel mills Boiler feed application Reverse osmosis for desalination plants water supply / general industry Fire fighting Special features / product benefits Mounting: Centreline/ vertical Multi-outlet design Balance valve design for axial thrust bush bearing/ roller bearing Technical data Qmax: 1000 m3/hr Hmax: 1800m Temperatur: up to 1600 C Delivery Size: DN 32 – DN 250
...moreMulti stage inline vertical pump
Multi stage inline vertical pump Application Water supply and pressure boosting Fire extinguishing systems Boiler feed Industrial circulation systems Process engineering Cooling water circulation systems Washing and sprinkling systems Special features / product benefits Stainless steel pump in inline design (only MVI 1.. to 8..) MVI 1.. to 8..: PN16 version with oval flange; PN25 version with round flange MVI 70.. and 95..: PN16 and PN25 version with round flange IE2-IEC standard motor Technical data Flow : upto 140 m3/hr Head: upto 220 m Temperature: up to 120°C Delivery size: DN 25 – DN 100 Minimum Efficiency Index (MEI) ≥ 0.4 Electrical connection: 1~230 V (±10 %), 50 Hz or optionally 220 V (±10 %), 60 Hz (up to 1.5 kW); only MVI 1.. – 8.. 3~230 V (±10 %), 50 Hz (Δ) or optionally 220 V (±10 %), 60 Hz (Δ) up to 4.0 kW, 400 V (±10 %), 50 Hz (Y) or optionally 380 V (±10 %), 60 Hz (Y) or 460 V (±10 %), 60 Hz (Y) from 4.0 kW Fluid temperature of -15 to +120 °C (with EPDM), (-15 to +90 °C with FKM) Operating pressure max. 16/25 bar Max. inlet pressure of 10 bar Protection class IP 55 Flange connections: MVI 1.. – 8.., PN 16; oval flange (G1 – G2) MVI 1.. – 8.., PN 25: Round flange (DN25 – DN40) MVI 1.. – 8.., PN 25: with optional Victaulic connections MVI 70../95.. PN 16/PN 25: Round flange (DN 100) Minimum Efficiency Index (MEI): ≥0.1
...moreJockey Pump
End suction, horizontal split case, multistage – single / multi outlet pumps with electric motor. Enclosure – TEFC / SPDP Voltage – 415V Frequency – 50 Hz