Volume Control Dampers
Dampers are available in 16g or 18g G.I multi blade construction fitted with galvaniszed 12.5 mm dia shaft and self lubricated bronze bushes provided with aluminium jam seal (compression type) to make damper low lekage operated with non spring return on off type actuator equipped with control panel.
...moresmoke damper
Both wall mounted & duct mounted dampers are available in heavy gauge G.1 multi blade construction fitted with galvaniszed 12.5 mm dia shaft and self lubricated bronze bushes also provided with S.S. jam seal (compression type) on side to prevent spread of smoke and fire. This is a motorized either spring return or non spring return acuator damper which activates on a signal from either an electronic thermal sensor (74 degree c UL stamped) mounted in the air stream or from the smoke detection system. the dampers are equipped with a 24 volts well designed control panel suitable with the acuator.
...moreslot diffusers
Attractively designed diffusers made of extruded aluminum mainly for installation into ceiling or sill. Can also be installed on walls, with or without Hit & Miss Dampers. Attractive Powder coated finish
...morePneumatic Air Damper
650 Per Square Feet
Material : Galvanized Steel (GI)
Shape : Rectangular
Mild Steel Fire Damper
Material : Mild Steel
Application : Fire protection
Linear Bar Grill
Manufactured by a mechanical assembly to ensure rigidity and maintain straight appearance. Available in 0°, 15° & 30° deflection. Made from high grade aluminium extrusion for maximum strength, corrosion resistance & dimensional stability. Also available in removable core form.
...moreLEAF ROUND DAMPERS
Dampers are available in all sizes starting from 150 mm dia to I000 mm dia constructed out of 20 g G.I machine grooved round sleeve & 20 g G.I. single round blade fitted on 12.5 mm dia galvanised shaft & self lubricated bronze bush available in both manual & motorized type.
...moreLaminar Flow Diffusers
Specially designed for clean room application with a perforated outlet to ensure a uniform and soft flow.
...moreIntake Louvers
G.I. rain protection intake louvers are available in both flange type and casette type with bird screen.
...moreInspection Windows
G.I inspection windows are available in single skin & double skin thermally acoustically insulated with thermocole or puf slab with hinges & and required locking arrangements.
...moregravity louvers
G.I. Gravity louvers are available in both duct type & wall mounted type constructed out of G.I. frame and light weight G.I. blades fitted on 9 mm dia shaft & plastic bush also available weight operated gravity louvers.
...moreGEAR DRlVEN DAMPERS
Dampers are available (Both Consealed type and Exposed type) in extruded aluminium section multi blade construction operated with abs gear & neoprene gasket at tips of blades to make dampers low lekage available in both manual & motorized type.
...moreFan Coil Units
our vast experience and specialisation in designing, performance and application problems in characterised by a superior range of units and such diverse conditions as coll, temperate and humid ones. casing available either in 18 / 20 g.i. Powder coated or 18 ggi duly painted blower made or aluminium is statically & dynamically balanced for smooth operation. fan motor sturdy three speed permanent split capacitor type fixed on proper resilient mounts. fandeck easily removable to facilitate speedier removal of motor or adjustment of fan wheel. drain pan liberally sized to cover the complete coil, water valve & fitting to catch the moisture from them. It is double skin in construction with 15mm tf insulation between 22 outer & 18g inner pan. option of s.s. Also available pans are with unique left/ right reversible connection feature. the unit can be installed with either left or right connection just by reversing the tray. cooling coil heat transfer cooling coil mode out or 10mm copper tubes and aluminium fins complete with purge.
...moreevaporative cooling machine
Direct Expansion Cooling Coil
CFC free PUF injected {25 mm43} panels in Double skin. CASING STRUCTURE (Thermal break on request.} Extruded alluminium hollow profiles frames self-supporting type.Designed for complete water drain inside made of alluminium304 stainless steel with alluminiumss drain nipple.
...moreIndustrial Dampers
Dampers are available in 16g/18g/20g/22g G.1 multi blade construction fitted with galvaniszed 12.5 or 9.00 mm dia shaft and self lubricated bronze or plastic bushes smoothly operated with bakelite knob fitted on quadrant.
...morecollar dampers
Aluminum extruded construction / M.S. Painted, with key type operation to regulate the air volume at individual grilled / diffusers. Plastic bushes provided for smooth operation
...moreair handing unit
Type:Horizontal, vertical, ceiling, suspended as per customer's requirement. Applications:Suitable for cooling, heating, humidification, ventilation PanelsCFC free PUF injected {25 mm/43} panels in Double skin.CASING STRUCTURE (Thermal break on request.}Extruded alluminium hollow profiles frames self-supporting type. Drain Pan:Designed for complete water drain inside made of alluminium/304 stainless steel with alluminium/ss drain nipple. Filter:Synthetic media filter are provided as standard microvee & Hepa Filter can also be provided on request. Coil Section:Optimum circuit designed coils are provided for maximum heat transfer as per duty requirements. Fans:Nicotra or Kruger centrifugal fans are used either SISW or DIDW type with forward curve or backward curved driven with V belts as per static pressure requirements. Inspection Doors:Provided with limit switch for safe maintenance of blower and blower motor. Optional Attachments:Mixing chamber with box type opposed Louvre dampers.Microvee filter chamber with Microvee filter.Hepa chamber filter with Hepa Filter.
...moreair grille
All extruded aluminium construction with adjustable blades, secured in nylon bushes to ensure quiet, smooth & rattle free operation, Suitable for any degree of deflection. Engineered to provide advantage of corrosion resistance & light weight construction.
...morefusible type dampers
fresh air intake louvres
fresh air grille
Registers
Be first to Rate
Rate This