Dental Solution Janakpuri, Delhi

  • X Ray Tube

    X Ray Tube

    Request for Price

    toshiba rotating anode x-ray tubes are applied to various kind of diagnostic applications. Toshiba rotating anode x-ray tubes are divided into several types by maximum tube voltage, anode heat capacity, focal spot size, etc. The rotating anode is constructed with specially processed rhenium-tungsten faced molybdenum target. Toshiba can supply x-ray tubes with or without housings. Since using iec60526 type high voltage cable receptacles, we can replace for other manufacturers' x-ray tubes.

    ...more
    Get Best Price
  • X-Ray Collimator

    X-Ray Collimator

    Request for Price

    Description The x-ray field is defined by 6 pairs of shutters, four of which are lead-lined. The six pairs of shutter move perpendicularly within the x-ray field. Two pairs of bronze shutters are located near the focus, two are located near the entrance window and two are located near the exit window of the x-ray beam from the collimator. The latter shutters serve to accurately define the x-ray field edges. Shutter movements are manual and controlled by two knobs silk-screened into the Lexan window and projected on the light field by the light beam. To activate the light field, press the area marked with the light symbol on the front of the device. The light will switch ON for 30 seconds and an electronic timer will switch the lamp OFF automatically. Average illumination is not less than 160 LUX; edge contrast ratio is minimum 4:1. Field size at the different Focus Film Distance (FFD- SID) settings is shown on the front panel. Features : External adjustment of mirror angulation High luminosity provided by a quartz iodide lamp Timer limiting projection lamp exposure time to 30 seconds thus extending lamp life by preventing overheating Radiation shielding: 125kVp - 4mA Minimum inherent filtration 2 mm aluminum equivalent (1 mm on request) Continuous film coverage from Min. 00 x 00 cm to Max. 43 x 43 cm at 100 cm FFD (SID) Optional Items: Mounting flange, leaded fixed type, 20 mm thickness Spacers, iron, 1.5 mm thickness for mounting flange Mounting flange, rotating type, diam 136, 18 mm thickness Mirror, 0.8 mm thickness - 1mm Al equivalent Single laser for collimator alignment with Potter Bucky Spacers, x-ray focus/patient Lead protection for external cover: 150kVp Upper cover for installation on fixed or rotating anode x-ray tubes The square-field X-Ray beam Limiting Device is designed for installation on rotating or fixed anode X-Ray tubes (EN 60601-1-3 par 29.202.3); manual controls provide for the adjustment of the X-Ray field dimension to the size of the image receptor or to that of the anatomical area of interest. Adjustment to the area under investigation is possible by using the knobs on the front panel. Direct visualisation of the X-Ray field is provided by a light beam which corresponds to the x-ray beam, within a tolerance of two percent of the selected FFD (SID) value. The light-field centre is provided by the intersection of two perpendicular lines. Contact Details   Claymount Assemblies Philippines Inc.Buildings 9, 10 & 11 Harvard AvenueEZP Business ParkCalamba Premiere International ParkSpecial Economic ZoneBatino, Calamba City4027 Laguna, PhilippinesT + 63 49 502 4520T + 63 49 502 4521F + 63 49 502 4500ph.office@claymount.com   Claymount High Voltage Technology (Beijing) Co., Ltd.Kang Sheng Industrial ParkBuilding # 2, 11 Kang Ding StreetBeijing Economic & Technological Development AreaBeijing 100176, ChinaT + 86 10 6780 2708T + 86 10 6780 2129F + 86 10 6780 2966

    ...more
    Get Best Price
  • lead aprons

    lead aprons

    Request for Price

    TECHICAL SPECIFICATIONS: 1. Hind (G-101): These are the belt type ergomicaly designed lead aprons for Indian market witha lead equivalence of 3.5mm. the open back allows freedom of movement, maximum flexibility and increased comfort. Available in Blue vinyl. 2. Care velcro (G-201) : These have been smartly designed with bouble colours and are wearable from both sides. They are the maximum selling aprons with lead equivalence of .50mm lead equivalence. Availble in marron and grey color they are worth the money. 3. Ortho (G-301): As the name suggests Ortho lead Aprons with .5 and 1.0 lead equivalence are best suited for surgeons specailly orthopaedicians who are exposed to long duration of X-Ray radiation. their wrap around concept gives complete coverage from the back and the double flap leaved no room wahtsoever for radiaition leakage. ortho featured extra wide shoulders distributing weight over a greater are to reduce fatigue. Available in Dark Red colour. 4. Radiograque (G-401) : These lead aprons come with .5lead equivalence and are most popular with radiologists and radiographers. the lower is joined separetely to give maximum comfort to the sholders and can be detached conveniently as per the requiremnt of the medical personnel. The lower can be used as skirt by female radiographers with the vests and are available in bright red color. 5. Global (G-501): Global .5mm Pb equivalence lead Free Aprons are intoduced once lead was considered a hazardous waste. The lead free attenuatuion effectiveness and desnsity over ranges from diagnostic imaging up tp Cobalt-60 energies (1.2 mev). Choosing appropruate materials for the energy range of intrest can offer improvedattenuation for the same garment weight than the traditional ones. the optimum methodical material used for the everlasting effect is Bi in Global aprons. The Bi absorption edge strongly absorbs at energies above 37.4 Kev, but with dramatic increase in efficiency below the edge. 6. Xtra Care (G-601) : A.5mm lead equivalence lead aprons Xtra Care is an artisan design noted for it's durability. Wherein the thyroid has been permanently attached to the Care velcro (G-201) Lead Apron. It gived complete front protection to the medical personnel and is available in Dark Green Color.

    ...more
    Get Best Price
  • intensifying screens

    intensifying screens

    Request for Price

    Outline Intensifying screens are made of highly sensitive phosphors and used with photofluorography. When we are X-rayed, they reduce irradiation to one hundredth of the ordinal irradiation without intensifying screens.     Advantages Our intensifying screens have high sensitivity and high sharpness by our technology that makes a high-density phosphor layer and prepares optimal grain size distribution. Sensitivity and sharpness are further improved by our structural designing that ensures effective light reflection and X-ray absorption characteristics. The surfaces of intensifying screens are protected with a special film to prevent darts and scars and to render handling easy.       Types and phosphor materials of intensifying screens Types and phosphor materials of intensifying screensTO-type screens use gadolinium oxisulfide with terbium (Gd2O2S:Tb) for orhto-type phosphor emitting green light. (Toshiba Ortho Type) E- and D-type screens use calcium tungstate (CaWO4) emitting blue light. Q-type screens use barium fluoro chloride with europium (BaFCl:Eu) emitting blue light Features: Adopts special plastic connecting angles, anti-pounding It is contacted evenly with its specially made high-elasticitysponge pad Imaging stably and clearly The imaging layer is clear as well The sponge pad is specially treated It can protect the intensifying screen not to be damaged Adopts the entire plane grid chart testing technique to insurethe quality of products   Specifications: 12.7 x 17.8cm (5 x 7") 20.3 x 25.4cm (8 x 10") 25.4 x 30.5cm (10 x 12") 27.9 x 35.6cm (11 x 14") 30.5 x 38.1cm (12 x 15") 35.6 x 35.6cm (14 x 14") 35.6 x 43.2cm (14 x 17")

    ...more
    Get Best Price
  • FLAT PANEL PENDULUM MOTION BUCKY SYSTEMS

    FLAT PANEL PENDULUM MOTION BUCKY SYSTEMS

    Request for Price

    The Pendulum Motion Advantage   Anti-scatter grid with Variable Pendulum Motion keeps grid lamellae 100% parallel to the X-Ray beam Potentially lower dose imaging depending on the techniques being used High remnant beam transmission for even density and shorter exposure times Line-free imaging with exposures as short as 10 mSec   The Claymount Pendulum Motion Bucky features our precision-controlled Variable Speed Drive Technology. Operating with the on-board software, the grid rapidly accelerates to its highest speed following synchronization contact and prior to emission. This ensures that the grid moves through its entire arc of travel during exposure which helps provide high contrast line-free images at a potentially lower dose. Each grid is fitted with encoder tabs that allow the control to detect the focal distance, ratio and line count of the grid, and optimize the Pendulum motion profile during exposure.

    ...more
    Get Best Price
  • CA1-type X-ray cables Connector

    CA1-type X-ray cables Connector

    Request for Price

    Claymount CA1 medical high voltage cable assemblies are X-ray cables terminated with 3-pin (O3) Federal Standard terminations rated for up to 100 kVDC. These assemblies fully comply with IEC 60526 and NEMA XR-7 standards, and are type tested under the severest life (aging) conditions. Features : A wide choice of small diameter, highly flexible cable types with 95% shielding coverage, rated for up to 100 kVDC. High temperature 100�C rated plugs, with replaceable spring contact pins. Maintenance-free plugs if silicone washer version is used. Small diameter flange - cable assemblies are slipped in easily - ring nut and bolted type divided flange for positive grounding to be mounted later.     Installation For maintenance-free installation of the plug into its receptacle, our silicone washer & oil set is recommended. First, the silicone washer is lubricated with silicone oil, and placed on top of the termination over the contact pins. Then, the connector is inserted into the receptacle, and the ring nut is tightened and secured with the grub screw. The silicone washer will absorb the applied silicone oil and swell, filling up the space between the top of the connector and the bottom of the receptacle and building up the necessary pressure, for adequate electrical insulation. In combination with our special connector and receptacle materials, the silicone washer is able to provide full 75 kVDC rated high voltage insulation. The washer is extremely simple to use, and unlike grease it is not messy at all. Moreover, common grease problems (especially at higher temperatures) like leaking, migration, and drying out, are non-existent when using the silicone washer. Therefore regreasing is not necessary, resulting in maintenancefree installation. The washer only needs to be replaced after the ring nut has been loosened. Of course, silicone grease is also available, or as an alternative transformer oil can be used. This plug can be installed with Claymount patented oil-seal mounting flange set to suit CT and likewise systems. Standard installation hardware for one Claymount cable assembly consists of two ring nuts, two divided flanges that can be mounted together with screws, two rubber sealing gaskets and two silicone rubber washer/oil sets. For 100 kVDC operation, installation with silicone grease or transformer oil is required.   Cable types The following cable types can be terminated with CA1-type   Description The plugs are made from a UL 94 5VA approved high insulation thermoplastic material and are filled with an insulation compound. The metal parts (directly moulded inserts, spring contact pins and grounding flange) are made from brass for a good conduction. As a unique feature, the contact pins are replaceable by means of a special tool in case of damage. The small outer diameter of the plugs allows an easy feed-through in C-arms and cable hoses. For long-lasting flexibility the soft PVC-sleeve is directly moulded on to the plug.

    ...more
    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
With its modest beginning as suppliers of X-Ray films since 2000 our Group is working on the policy to assure the quality and reliability of all the products that they sell. Working ardently since past 12 years in this direction has made Global Imaging a well known name amongst the small and big manufacturers in India. We are an ISO certified organization credited for providing high quality Imaging machines' spares and dental products. Our company holds the advantage of launching Leadglasses in 2001, Chinese tubes and Toshiba Image Intensifiers in 2005, Claymount Cables in 2006, Toshiba Intensifying Screens and AEC in 2007, ODI Grids and CCD detector in 2008, Toshiba Fixed DR Panels in 2009, H/F Generators in 2010, Smit Carbon Fibre Grids for CR and DR in 2011 and VDL Phantoms and Carbon Fibre Table tops for Cath Labs in 2012. Our sales research team is now working continuously towards expanding our horizons in India and abroad with Sensors and H/F Dental X-Ray. Our technical expertise and years of experience has helped us to carve a niche for ourselves in the market. The efforts have yielded results with our company as pioneers and leaders in Indian manufacturers segment. Performing at top since inception, the group has consistently doubled its sales and profits every two years. The pioneering management has spared no efforts in making the group as one of the few planned solution providers in the market.
Read More »

Contact Information

Dental Solution

  • Dental Solution
  • WZ-12B, Asalatpur Market A3 Block, Janak Puri New Delhi-110058, Janakpuri
top