Trinity Electrosurgical Unit
Get Price Quote
Trinity Electrosurgical Unit provides consistent performance by using the latest and reproducible technology used to command the functionality as the need of surgical application. It comes with ten programs for different specialties. On site program facility is possible. Three different modes of cut, coag and bipolar can be stored individually in each program. The Trinity Electrosurgical Unit is equipped with True digital power readout with dosage error control. It also has Self diagnostic mode with error display (25 error messages) Spark sensor technology and RS-232 interface. Advanced Performance Features Monopolar-Computer Controlled intelligent cut with Feedback Response System Three Cut Modes ΓΆ€“ (Auto Cut-Optional)Pure cut suitable for under water cutting (TURP, TUVP & TCRE) with URO-CUT, which eliminates lag time in initiating cut especially suited for urological procedure.Three Blend ΓΆ€“ Modes(Program)Low Cut- endocut (Gastro cut)- for G.I. SurgeryThree Coag Modes ΓΆ€“ (Auto Coag-Optional)Desiccation/Soft ΓΆ€“ for low voltage soft coagulation suitable for laparoscopic & delicate tissue work.Fulgurate/Forced ΓΆ€“ non contact Coagulation for minimal smoke generationSpray for non-contact large tissue area coagulation with minimum depth of necrosis.Bipolar-SLS (Computer controlled Self Limiting System-Unmodulated-Auto Optional)Micro ΓΆ€“ for delicate tissue work by controlled desiccation without charring, adhesion or blanching of adjacent tissue. (Ophthalmic & neurosurgery).Macro- for new generation of macro bipolar cutting instrument (Tri-polar) for LAVH procedure etc. when used with BIPOL probes provides excellent tamponade capabilitiesPlasma Bipolar (PB) - Advanced computerized wet field Bipolar works under blood, saline etc. Advanced Safety Features PPCQM- Patient to Patient plate contact Quality monitoring technology ΓΆ€“ monitors the quality & quantity of contact between the patient & the patient plate. If this contact is not proper the unit deactivates & alarms, thus eliminating any risk of Passive electrode Site burns. (Optional)It deactivates the unit & alarms in case of any discontinuity in the patient plate cord. Exclusive PEM (Patient Electrode monitoring)Isolated RF output directs current to return back to the generator to reduce the risk of Alternate site burns & to ensure patient safety in case of any discontinuity in patient plate cord. This current has no reference to ground so it does not cause notice able interference with the ECG monitor, Cardiac pace maker etc.Independent activation of hand switching, foot switching & bipolar output to protect against inadvertent output from an idle accessory lying on or near the patient or surgical staff.Class '2' leakage cancelling, a must for lengthy procedure like Cardiac surgery (CABG) etc.Meets all general requirements of safety for Electromagnetic compatibility (EMC) as per IEC-60601-1-2 including 36.201 (CISPR 11 Group 1) ΓΆ€“ Emissions, 36.202-Immunity and 36.202.1-General. Enhanced Operating Convenience Separate Bipolar generator controls and footswitch with auto selectivity reduces the dependency on the operating room staff during the procedure.Two independent hand switching monopolar outputs and one hand switching bipolar output combined with Laparoscopic Clipons, eliminates the need of footswitches during endoscopic procedures.Ergonomically designed trolley to house diathermy, accessories, argon unit with cylinders and smoke evacuatorComprehensive clinical training network through workshops, seminars, videos & literatures Up gradations 'Vessel Sealing System' both for open and Laparoscopic Surgeries ΓΆ€“ 'TRINITY-LS.Upgradation into Dual Generator system for C.T.V.S. Surgeries with specialized IMA- program (Internal Mammary Artery Harvesting)- and vessel sealing system for Endo Vessel Harvesting 'TRINITY-CT'Easily upgradable into Argon-Beamer with DIV-ARGON ModuleCompatible with DIV-VAC smoke evacuator Upgradable with DIV-BCM Bipolar current monitorCompatible with DIV-AES Active electrode safety system.Compatible with DIV-RFTA Radio frequency thermal ablation Used with CUSA CEM ModuleUnder Saline Bipolar Turp-Trinity-NaCI Specifications TypeModeOutput Freq. (kHz)Maximum P-P VoltageRated Load (ohms)Max. Power (watts)Crest Factor*PER*Duty CycleBipolarMicro/CoagMacro/CutPlasma500500700380480T.D100100T.D99991502.51.5T.D98N/AN/AN/AMonopolar CutPure/Cut 1Blend/Cut 2Endo/Gastro Cut5005005001800260015003005002004002002501.52.41.898N/A75%50%Monopolar CoagSoft/DesiccateForced/FulgurateSpray4504504502300600095001505005001501501504.47.28.09725%6.5%4.6% Weight and DimensionsWeight10kgLength390mmHeight130mmWidth340mmCurrent LeakageHigh Frequency leakage
Surgical Cautery
Get Price Quote
Surgical Cautery, Medical Equipments, Colour Doppler ultrasound
Best Deals from Electrosurgical Units
Electrosurgical Units
Get Price Quote
Electrosurgical Units, laparoscopic electrodes, Loop Electrodes
Surgical Cautery
Get Price Quote
Surgical Cautery, monitors, surgical curettes, xray machine