  • Digital Fluorometer

    Digital Fluorometer

    28,000 Per piece

    1 piece (MOQ)

    • Model: 781R
    • Display: 3 Digit Bright Red Seven Segment Led Display
    • Excitation Source: 12v, 50w Tungsten Halogen Lamp
    • Sensitivity Ranges: Adjustable In 4 RangesSensitivity Ranges
    • Primary Filters: Corning 5840 And Corning 5113 Mounted On Holders
    • Secondary Filters: Coming 4308, Corning 3486, Corning 3385 Mounted On Holders
    • Detector: Highly Sensitive Wide Range Photodiode/Dell
    • Samples Test Tube: 15mm (D) X 80 Mm (H)
    • Minimum Sample: 4ml
    • Power: 230v + 10%, 50 Hz. Ac
    • Dimensions: 262x340x165 Mm (Approx.)
    • Weight: 5kg.(Approx.)
    • Accessories: Primary And Secondary Filters :- A Set Of 5, Test Tube:- A Set Of 5,
    more..
  • Qubit 4 Starter Digital Photo Fluorometer with WiFi

    Qubit 4 Starter Digital Photo Fluorometer with WiFi

    Get Price Quote

    1 1 kit (MOQ)

    Sample Volume 1 to 20 µL Includes Fluorometer, Assay Tubes, Wi-Fi Dongle, Assay Kit Excitation Wavelength 470 nm (Blue LED), 635 nm (Red LED) For Use With (Equipment) Qubit Fluorometer Product Line Qubit™ Type Qubit 4 RNA IQ Starter Kit, with WiFi For Use With (Application) sdDNA Quantification, RNA Quantification, Protein Quantification Unit Size 1 kit  

    more..
  • Best Deals from Fluorometer

  • PAM-2500 Portable Chlorophyll Fluorometer

    PAM-2500 Portable Chlorophyll Fluorometer

    Get Price Quote

    For basic and applied research; plant screening,Fully computer controlled; optional ultra-mobile PC for field work and touch screen operation,Optional accessories for algae and cyanobacteria

    more..
  • CL-01 Chlorophyll Content System

    CL-01 Chlorophyll Content System

    Get Price Quote

    • Features: User-friendly, low cost chlorophyll content meter Field portable, light-weight, robust design Dual wavelength optical absorbance (620 and 940nm)

    The CL-01 Chlorophyll content meter provides a convenient, low cost method of measuring the relative chlorophyll content of a leaf sample. The measurement of chlorophyll content provides an indicator of photosynthetic activity relating to the nitrogen concentration of the sample. This is particularly significant in plant growth programs where affects of the addition of nitrogen to a crop may be closely monitored. The field-portable, hand-held device determines relative chlorophyll content using dual wavelength optical absorbance (620 and 940nm wavelength) measurements from leaf samples. Relative chlorophyll content is displayed in the range 0 – 2000 units.

    more..
  • fluorometer

    fluorometer

    Get Price Quote

    • Light Source: LED
    • Dynamic Range: Five Orders of Magnitude
    • Linear Dynamic Range: R>0.995
    • Detector: Photodiode
    • Repeatability: <1.5%
    • Stability: <1.5%
    • Sensitivity: dsDNA:0.5ng/ml
    • Measurement Speed: 3s(Once)
    • Dimension(WxDxH)mm: 194x155x72.5mm
    • Weight kg: 0.4kg
    more..
  • fluorometer

    fluorometer

    Get Price Quote

    01 Set(s) (MOQ)

    • Model Number: LILE-723
    • Place of Origin: Delhi, INDIA
    • Usage: Analysis of Pharmaceutical products, particularly vitamins.
    • Power: 220 Volts, 50 Hz.

    In a filter fluorometer, a light source emits light of an excitation wavelength that is relevant to the compound to be measured. Filter fluorometers produce specific excitation and emission wavelengths by using optical filters. The filter blocks other wavelengths but transmits wavelengths relevant to the compound. The light passes through the sample to be measured, and a certain wavelength is absorbed while a longer wavelength is emitted. The emitted light is measured by a detector. By changing the optical filter, different substances can be measured. SALIENT FEATURES â€Â¢ Highly sensitive, a full scale reading of 199.9 can be adjusted even with 0.2 ppm of quinine sulphate solution in 0.1 N sulphuric acid & primary filter of peak transmission at 366 nm. â€Â¢ Only 5 ml of sample needed. â€Â¢ Range Selection in four steps. â€Â¢ Coarse & Fine gain Adjustment and Offset Adjustment. â€Â¢ Separate power ‘ON’ switch for Lamp to conserve life of the Lamp. APPLICATIONS â€Â¢ Analysis of Pharmaceutical products, particularly vitamins. â€Â¢ Metallurgy â€Â¢ Chemical Industries â€Â¢ Research Institutions

    more..
  • fluorometer

    fluorometer

    Get Price Quote

    • Lamp: 12V, 50W Tungsten Halogen Lamp
    • Minimum Sample: 4 ml
    • Power: 230 V ± 10%, 50 Hz. AC

    With PXFL681, a digital photofluorometer, you can perform precise analysis of flurophors and quinine. Designed specifically for life science laboratories, this smart instrument fulfills your requirements of accurate results with the sensitivity you demand. This fluorometer is a compact system, which occupies very low bench space, while offering convenient and excellent throughput for fluorescence assays. It is a low cost fluorometer model has been designed and manufactured for laboratories, where routine analysis of fluorophors is a prime requisite. This system uses 50 W tungsten halogen lamp, Corning 5840 and Corning 5113 primary filters and Corning 4308 and Corning 3486 secondary filters, ensuring excellent fuoro sensitivity; full scale deflection obtained with 1 ppm quinine sulphate in 0.1 N sulphuric acid (primary wavelength 360 nm).